Displaying all 5 publications

Abstract:
Sort:
  1. Bastidas A, de la Serna J, El Idrissi M, Oostvogels L, Quittet P, López-Jiménez J, et al.
    JAMA, 2019 07 09;322(2):123-133.
    PMID: 31287523 DOI: 10.1001/jama.2019.9053
    Importance: Herpes zoster, a frequent complication following autologous hematopoietic stem cell transplantation (HSCT), is associated with significant morbidity. A nonlive adjuvanted recombinant zoster vaccine has been developed to prevent posttransplantation zoster.

    Objective: To assess the efficacy and adverse event profile of the recombinant zoster vaccine in immunocompromised autologous HSCT recipients.

    Design, Setting, and Participants: Phase 3, randomized, observer-blinded study conducted in 167 centers in 28 countries between July 13, 2012, and February 1, 2017, among 1846 patients aged 18 years or older who had undergone recent autologous HSCT.

    Interventions: Participants were randomized to receive 2 doses of either recombinant zoster vaccine (n = 922) or placebo (n = 924) administered into the deltoid muscle; the first dose was given 50 to 70 days after transplantation and the second dose 1 to 2 months thereafter.

    Main Outcomes and Measures: The primary end point was occurrence of confirmed herpes zoster cases.

    Results: Among 1846 autologous HSCT recipients (mean age, 55 years; 688 [37%] women) who received 1 vaccine or placebo dose, 1735 (94%) received a second dose and 1366 (74%) completed the study. During the 21-month median follow-up, at least 1 herpes zoster episode was confirmed in 49 vaccine and 135 placebo recipients (incidence, 30 and 94 per 1000 person-years, respectively), an incidence rate ratio (IRR) of 0.32 (95% CI, 0.22-0.44; P 

  2. Rengarajan A, Rogers BD, Wong Z, Tolone S, Sifrim D, Serra J, et al.
    Clin Gastroenterol Hepatol, 2022 Mar;20(3):e398-e406.
    PMID: 33144149 DOI: 10.1016/j.cgh.2020.10.052
    OBJECTIVE: High-resolution manometry (HRM) is the current standard for characterization of esophageal body and esophagogastric junction (EGJ) function. We aimed to examine the prevalence of abnormal esophageal motor patterns in health, and to determine optimal thresholds for software metrics across HRM systems.

    DESIGN: Manometry studies from asymptomatic adults were solicited from motility centers worldwide, and were manually analyzed using integrated relaxation pressure (IRP), distal latency (DL), and distal contractile integral (DCI) in standardized fashion. Normative thresholds were assessed using fifth and/or 95th percentile values. Chicago Classification v3.0 criteria were applied to determine motor patterns across HRM systems, study positions (upright vs supine), ages, and genders.

    RESULTS: Of 469 unique HRM studies (median age 28.0, range 18-79 years). 74.6% had a normal HRM pattern; none had achalasia. Ineffective esophageal motility (IEM) was the most frequent motor pattern identified (15.1% overall), followed by EGJ outflow obstruction (5.3%). Proportions with IEM were lower using stringent criteria (10.0%), especially in supine studies (7.1%-8.5%). Other motor patterns were rare (0.2%-4.1% overall) and did not vary by age or gender. DL thresholds were close to current norms across HRM systems, while IRP thresholds varied by HRM system and study position. Both fifth and 95th percentile DCI values were lower than current thresholds, both in upright and supine positions.

    CONCLUSIONS: Motor abnormalities are infrequent in healthy individuals and consist mainly of IEM, proportions of which are lower when using stringent criteria in the supine position. Thresholds for HRM metrics vary by HRM system and study position.

  3. Rogers BD, Rengarajan A, Abrahao L, Bhatia S, Bor S, Carlson DA, et al.
    Neurogastroenterol Motil, 2021 06;33(6):e14009.
    PMID: 33094875 DOI: 10.1111/nmo.14009
    BACKGROUND: Esophagogastric junction contractile integral (EGJ-CI) and EGJ morphology are high-resolution manometry (HRM) metrics that assess EGJ barrier function. Normative data standardized across world regions and HRM manufacturers are limited.

    METHODS: Our aim was to determine normative EGJ metrics in a large international cohort of healthy volunteers undergoing HRM (Medtronic, Laborie, and Diversatek software) acquired from 16 countries in four world regions. EGJ-CI was calculated by the same two investigators using a distal contractile integral-like measurement across the EGJ for three respiratory cycles and corrected for respiration (mm Hg cm), using manufacturer-specific software tools. EGJ morphology was designated according to Chicago Classification v3.0. Median EGJ-CI values were calculated across age, genders, HRM systems, and regions.

    RESULTS: Of 484 studies (28.0 years, 56.2% F, 60.7% Medtronic studies, 26.0% Laborie, and 13.2% Diversatek), EGJ morphology was type 1 in 97.1%. Median EGJ-CI was similar between Medtronic (37.0 mm Hg cm, IQR 23.6-53.7 mm Hg cm) and Diversatek (34.9 mm Hg cm, IQR 22.1-56.1 mm Hg cm, P = 0.87), but was significantly higher using Laborie equipment (56.5 mm Hg cm, IQR 35.0-75.3 mm Hg cm, P 

  4. Sifrim D, Roman S, Savarino E, Bor S, Bredenoord AJ, Castell D, et al.
    Gut, 2020 Oct 09.
    PMID: 33037054 DOI: 10.1136/gutjnl-2020-322627
    OBJECTIVE: Limitations of existing impedance-pH thresholds include small sample size of normative studies, inclusion of artefactual pH drops and incorrect identification of impedance reflux events. We aimed to obtain new impedance-pH thresholds from expert consensus analysis of tracings from a large number of healthy subjects.

    DESIGN: Of 541 studies performed worldwide using two different systems (Diversatek, USA, and Laborie, Netherlands), 150 tracings with oesophageal diagnoses, behavioural disorders and study-related artefacts were excluded. The remainder studies were subject to two reviewer consensus analysis, in-person or through video conference, consisting of editing meals and pH drops, identification of impedance reflux and postreflux swallow-induced peristaltic wave (PSPW) using strict pre-established criteria and measurement of distal mean nocturnal baseline impedance (MNBI).

    RESULTS: Consensus analysis was performed in 391 tracings (age 32.7 years, range 18-71, 54.2% female). Normative thresholds were significantly different between Diversatek and Laborie (total acid exposure time: 2.8% and 5%; reflux episodes: 55 and 78; MNBI at 3 cm: 1400 and 1500 ohms, at 5 cm: 1400 and 1800 ohms). Males had higher acid exposure, more reflux episodes and lower MNBI. Significant regional differences were identified, including higher PSPW scores in Western countries, and higher MNBI in Asia using Diversatek, and higher acid exposure in the Netherlands, higher MNBI in Asia and South Africa, and lower MNBI in Turkey using Laborie.

    CONCLUSION: Normal impedance-pH monitoring thresholds have regional and system-related differences. Clinical interpretation needs to use normal thresholds valid for the system used and world region, following careful editing of the tracings.

  5. Kruszka P, Porras AR, de Souza DH, Moresco A, Huckstadt V, Gill AD, et al.
    Am J Med Genet A, 2018 05;176(5):1128-1136.
    PMID: 29681090 DOI: 10.1002/ajmg.a.38672
    Williams-Beuren syndrome (WBS) is a common microdeletion syndrome characterized by a 1.5Mb deletion in 7q11.23. The phenotype of WBS has been well described in populations of European descent with not as much attention given to other ethnicities. In this study, individuals with WBS from diverse populations were assessed clinically and by facial analysis technology. Clinical data and images from 137 individuals with WBS were found in 19 countries with an average age of 11 years and female gender of 45%. The most common clinical phenotype elements were periorbital fullness and intellectual disability which were present in greater than 90% of our cohort. Additionally, 75% or greater of all individuals with WBS had malar flattening, long philtrum, wide mouth, and small jaw. Using facial analysis technology, we compared 286 Asian, African, Caucasian, and Latin American individuals with WBS with 286 gender and age matched controls and found that the accuracy to discriminate between WBS and controls was 0.90 when the entire cohort was evaluated concurrently. The test accuracy of the facial recognition technology increased significantly when the cohort was analyzed by specific ethnic population (P-value 
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links