This study explored the use of silver nanoparticle as a bactericidal against the propagation of Clavibacter michiganensis onto tomatoes (Lycopersicon esculentum Mill). In Mexico, tomato production covers about 73% of the total vegetable production but it is affected by outbreak of bacteria canker caused by Clavibacter michiganensis subspecies michiganensis (Cmm). Silver ions possess inhibitor properties, bactericides and high specter antimicrobials. In this study, 6 groups of culture were prepared using 6 different petri dishes where silver nanoparticles of varying concentrations (120, 84, 48, 24, 12 and 0 μg) were added. Furthermore, each group was observed for 20 min, 1, 2, 12 and 24 h. The optimum concentration is 84 μg, which shows an average of 2 Cmm colonies after 20 min. Further increase to 120 μg shows no significant change. However, the average colonies was observed for 48 μg after 1, 2, 12, and 24 h. The obtained results indicate that silver nanoparticles are a promising inhibitor, bactericide and high a specter antimicrobial for treatment or prevention of Cmm.
A microstrip circuit is designed, constructed, and tested based on the nest microstrip add-drop filters (NMADF). The multi-level system oscillation is generated by the wave-particle behaviors of AC driven along the microstrip ring circular path. The continuous successive filtering is applied via the device input port. The higher-order harmonic oscillations can be filtered, from which the two-level system known as a Rabi oscillation is achieved. The outside microstrip ring energy is coupled to the inside rings, from which the multiband Rabi oscillations can be formed within the inner rings. The resonant Rabi frequencies can be applied for multi-sensing probes. The relationship between electron density and Rabi oscillation frequency of each microstrip ring output can be obtained and used for multi-sensing probe applications. The relativistic sensing probe can be obtained by the warp speed electron distribution at the resonant Rabi frequency respecting the resonant ring radii. These are available for relativistic sensing probe usage. The obtained experimental results have shown that there are 3-center Rabi frequencies obtained, which can be used for 3-sensing probes simultaneously. The sensing probe speeds of 1.1c, 1.4c, and 1.5c are obtained using the microstrip ring radii of 14.20, 20.12, and 34.49 mm, respectively. The best sensor sensitivity of 1.30 ms is achieved. The relativistic sensing platform can be used for many applications.