    The Climatic performance of courtyard residential buildings needs to be
    investigated if the assertion that courtyard is a microclimate modifier is to be
    accepted. Therefore, this study seeks to examine the microclimatic performance
    of two existing courtyard residential buildings with similar characteristics in
    Kafanchan-Kaduna Nigeria, -the fully enclosed courtyard residential building and
    the semi-enclosed courtyard residential building. The purpose of this research is
    to investigate their microclimatic performances in other to establish the best
    courtyard house. This study uses measurement to achieve its aim. The tool
    employed for data collection is the Hobo Weather Data Loggers (HWDL). Three
    HWDL were used to collect data in the two case-study, and the third one was
    placed in the outside area as a benchmark. Only air temperature and relative
    humidity were measured. This study revealed a tangible difference in the
    microclimatic performance of the two case-study. The fully enclosed courtyard
    residential building is seen to have air temperature difference of 1 oC to 3 oC, and
    the relative humidity difference of 4 % to 8 %. In conclusion, the fully enclosed
    courtyard house demonstrated a more favorable microclimatic performance than
    the semi-enclosed, and further simulation studies towards its optimization are
    required.
  2. Markus Bulus, Lim, Yaik-Wah, Malsiah Hamid
    MyJurnal
    Scholars have opined that the courtyard is a passive architectural design element and
    that it can act as a microclimate modifier provided that its design requirements are not
    ignored. But despite the assertions, empirical studies on the microclimatic
    performance of a fully enclosed courtyard house and the non-courtyard house seems
    to be deficient, and the assumption that the Courtyard is a passive architectural design
    element needs to be substantiated. Therefore, the purpose of this study is to
    investigate the microclimatic performance of a fully enclosed courtyard and noncourtyard
    residential buildings. The main objective is to compare their microclimatic
    performances in other to draw a conclusion on the best option. Three Hobo Weather
    Data Loggers were used to collect climatic data in the buildings, and the third one was
    situated in the outdoor area as a benchmark. The climatic variables investigated are;
    air temperature and relative humidity. The fully enclosed courtyard residential building
    is seen to have a better air temperature difference of 2 oC to 4 oC and the relative
    humidity of 2 % to 6 %. In conclusion, the fully enclosed courtyard residential building
    has confirmed a more favorable microclimatic performance, and future studies
    towards its optimization are recommended.