Displaying all 15 publications

Abstract:
Sort:
  1. Norhamdan, M.Y., Shahril, Y, Masbah, O., Siti Aishah, M.A.
    Malays Orthop J, 2008;2(2):31-33.
    MyJurnal
    We report a case of 29-year-old female who presented with right heel pain that worsened over a period of two years. The onset of pain was followed by swelling at the medial aspect of right ankle. She was initially treated for plantar fasciitis with multiple steroid injections over the heel. Subsequent MRI revealed a well-defined heterogeneous lesion in continuity with the medial plantar nerve. Excision biopsy was performed and histopathological evaluation revealed monophasic synovial sarcoma. The patient subsequently underwent wide resection and free tissue transfer followed by radiotherapy and chemotherapy. This case highlights an unusual site and presentation of synovial sarcoma which led to delayed diagnosis and treatment.
  2. Suhail, A., Idham, H., Norhamdan, M.Y., Shahril, Y., Masbah, O.
    Malays Orthop J, 2009;3(2):33-35.
    MyJurnal
    Objective: To evaluate the early results of patients in a single institution who underwent total knee arthroplasty using an implant system. Methods: We retrospectively reviewed 76 total knee replacements using the Genesis II prosthesis (Smith and Nephew, Memphis) in 60 patients (16 were bilateral cases) performed between February 2005 andFebruary 2008. Patient related outcomes and clinical evaluations were done by an independent observer. Knee function and patient satisfaction were evaluated using the American Knee Society (ASK) score and the Western Ontario and Mac Master University Osteoarthritis Index (WOMAC). Results: The mean age of the patients at the time of operation was 63.5years. The mean follow up period was 1 year 5 months. At the final follow up, the mean Knee Society Knee Score was 87.9 with 77.3% (58 knees) rated excellent, 21.3% (16 knees) rated good and1.3% (1 knee) rated fair; none were rated poor. The mean Function Score was 87.1 with 64% (48 knees) rated excellent, 29.3% (22 knees) rated good, 6.7% (5 knees) rated fair, no knee was rated poor. The mean WOMAC Score was 94.4 (standard deviation 6.59). Conclusion: Most patients treated for knee osteoarthritis with total knee replacement showed high rates of excellence and good early functional outcomes.
  3. Harjeet, S., Suhail, A., Shahril, Y., Masbah, O., Subanesh, S.
    Malays Orthop J, 2009;3(1):24-27.
    MyJurnal
    Fracture of the femoral neck is one of the most common types of osteoporotic fractures. Hemiarthroplasty continues to be a good option despite current calls for total hip arthroplasty in this subset of patients. The hemiarthroplasty is less expensive and easier to perform, and can be adequately carried out in smaller hospitals with basic orthopaedic facilities staffed by general orthopaedists. Functional demands of the elderly among Asians are often less compared to similar subsets of Western population on which most comparative hip studies are based. This study was undertaken to investigate the outcome for femoral neck fractures treated with conventional hemiarthroplasty. The authors hope to provide information based on local data as a reference for our doctors and patients.
  4. Masbah O, Noor MA
    Med J Malaysia, 1992 Jun;47(2):122-7.
    PMID: 1494332
    The results of treatment using a locally-designed external fixator in 20 patients are presented. Open fractures were the main indications for external fixation. Pin tract infection occurred in 8 patients. Only 2 patients had unstable fixation which required removal of the device. One third of patients developed malunion exceeding 15 degrees and two thirds had joint stiffness after conversion to plaster cast. This external fixator is adequate in the treatment of most open fractures of the tibia. However, improved techniques of pin insertion and cast application upon removal of the external fixator may help to reduce the incidence of pin tract infections and malunion.
  5. Suhail,A., Gunalan, Sabarul, A ., Shahril, Y., Salasawati, H., Masbah, O.
    Malays Orthop J, 2008;2(2):1-5.
    MyJurnal
    Infection after joint replacement surgery is problematic and difficult to treat. The utility of antibiotic laden bone cement for reduction of risk of infection in primary and revision joint replacement surgery has already been established in many studies. In this study, we examined the efficacy of bone cement containing cefuroxime, employing a modified in vitro Kirby-Bauer susceptibility model for investigation of 13 strains of organisms that are found in orthopaedic infections. Organisms investigated were broad spectrum and effective for Gram-positive, Gram-negative, aerobic organisms and anaerobes. Simplex P with added cefuroxime was effective against 8 out of 13 strains. Cefuroxime is stable during exothermic polymerisation of the cement, and is released from the cement at concentrations high enough to inhibit the growth of most organisms encountered after joint arthroplasty.


  6. Pan KL, Masbah O, Ali M
    Med J Malaysia, 2001 Jun;56 Suppl C:19-25.
    PMID: 11814243
    A retrospective review of 30 intraarticular fractures of the distal radius in 27 patients was done. Only young adults aged between 18 and 40 were included. Road traffic accidents accounted for 25 of the cases (23 motorcyclists). Fourteen fractures were treated by closed reduction and a plaster cast. Sixteen fractures were treated by open reduction with internal fixation using a buttress plate or multiple Kirschner wires. At a mean follow-up of 17 months, 63% of the wrists had a satisfactory result and 37% unsatisfactory result. The main adverse factor was intraarticular congruity. The grip strength on the injured side averaged 56% of that of the uninjured side and the pinch strength averaged 73%. Most of the patients were able to return to their former occupation in an average of four months.
  7. Pan KL, Masbah O, Razak M
    Med J Malaysia, 2001 Jun;56 Suppl C:73-5.
    PMID: 11814255
    A case of late reconstruction of the patellar tendon is reported. Besides partial loss of the tendon, the patient also had loss of the distal third of the patella. A rolled strip of fascia lata was used to reconstruct the tendon with tunnels through the patella. At the tenth month of follow-up, the result was deemed successful.
  8. Pan KL, Masbah O, Razak M
    Med J Malaysia, 2000 Jun;55(2):268-70.
    PMID: 19839159
    A rare combination of a segmental ulnar fracture with fracture dislocation of the head of the radius and intraarticular fracture of the distal radius concomitant with an ipsilateral scaphoid, lunate and coronoid process fractures is presented. The mechanism of injury could possibly be a tremendous impact on the outstretched hand with a dorsiflexed wrist, fracturing the carpal bones and the distal radius. Transmitted axial forces on the ulna in a pronating forearm resulted in the other fractures. To the best of our knowledge, no such case has been reported. Open reduction with screw fixation of the scaphoid, plating of the proximal ulna and Kirschner wiring of the distal radius and radial head dislocation were done.
  9. Noor MA, Masbah O, Lumpur K
    J Hand Surg Am, 1997 May;22(3):508-10.
    PMID: 9195463
    Glomus tumors occurring synchronously in the subungual region and the pulp of a fingertip are extremely uncommon. Awareness of this will lead to early diagnosis and treatment.
  10. Ruzaimi MY, Shahril Y, Masbah O, Salasawati H
    Med J Malaysia, 2006 Feb;61 Suppl A:21-6.
    PMID: 17042224
    Deep surgical site infection is a devastating consequence of total joint arthroplasty. The use of antibiotic impregnated bone cement is a well-accepted adjunct for treatment of established infection and prevention of deep orthopaedic infection. It allows local delivery of the antibiotic at the cement-bone interface and sustained release of antibiotic provides adequate antibiotic coverage after the wound closure. Preclinical testing, randomised and clinical trials indicate that the use of antibiotic-impregnated bone cement is a potentially effective strategy in reducing the risk of deep surgical site infection following total joint arthroplasty. The purpose of this study was to assess antibacterial activity of erythromycin and colistin impregnated bone cement against strains of organisms' representative of orthopaedic infections including Gram-positive and Gram-negative aerobic organisms: Staphylococcus aureus, coagulase-negative Staphylococci, Enterococcus sp., Proteus sp., Klebsiella sp., Pseudomonas sp., and Escherichia coli. Pre-blended Simplex P bone cement with the addition of erythromycin and colistin (Howemedica Inc) was mixed thoroughly with 20ml liquid under sterile conditions to produce uniform cylindrical discs with a diameter of 14mm and thickness of 2mm. 24-48 hour agar cultures of Staphylococcus aureus, coagulase-negative Staphylococci, Enterococcus sp.,Proteus sp., Klebsiella sp.,Pseudomonas sp., and Escherichia coli were used for the agar diffusion tests. The agar plates were streaked for confluent growth followed by application of erythromycin and colistin impregnated bone cement disc to each agar plate. The plates were incubated at 30 degrees C and examined at 24, 48, 72 hours, and four and five days after the preparation of the impregnated cement. The susceptibility of Staphylococcus aureus to the control discs was most clearly demonstrated showing a distinct zone of inhibition. The zone observed around coagulase-negative Staphylococci, Klebsiella sp., Pseudomonas sp., and Escherichia coli were also significant. However, there was no zone of inhibition or signs of antibacterial activity at the cemented surface were detected around discs with Enterococcus sp. and Proteus sp. The results showed that Simplex P bone cement with the addition of erythromycin and colistin was effective against most of the broad spectrum organisms encountered during total joint arthroplasty. The activity of Simplex P bone cement impregnated with erythromycin and colistin is mainly during the first 72 hours.
  11. Nizlan MNM, Suhail A, Samsudin OC, Masbah O
    Med J Malaysia, 2004 Dec;59 Suppl F:65-8.
    PMID: 15941168
    A case of traumatic posterior cruciate ligament (PCL) avulsion fracture presenting with unusual radiographic findings is described. CT scan of the right knee showed features suggestive of combined ACL and PCL avulsion fractures. Arthroscopic findings showed that the injury was in fact a PCL avulsion fracture that was displaced anteriorly so as to mimic an ACL avulsion fracture on CT scan.
  12. Tay BH, Masbah O, Razak M, Ruslan GNS
    Med J Malaysia, 2000 Sep;55 Suppl C:74-85.
    PMID: 11200048
    The results of 109 primary total hip arthroplasties in 92 patients performed in Hospital Kuala Lumpur from January 1987 to December 1996 were reviewed after a mean follow-up of 30.8 months. There were 22 males and 70 females with the average age of 49.9 years (range 19 to 94 years). Chinese females comprised the largest group of patients (52.2%). Avascular necrosis was the most common diagnosis (33.1%) followed by hip dysplasia and primary osteoarthritis (17.4%). The procedure was performed more on the right hip (64.2%) compared to the left (35.8%). All patients received prophylactic antibiotics but none were given deep vein thrombosis prophylaxis. The Charnley prosthesis was most commonly used and the majority of the arthroplasties were cemented (60.5%). About 80% of the THA were performed via the lateral approach. The functional hip score improved from an average of 8.9 to 15.0 with 66.3% of the patients categorized as good and excellent results. There were 16 patients (17.4%) with poor outcome. The most common complications encountered were dislocation (10.1%), aseptic loosening (9.2%) and periprosthetic fracture (5.5%). Other complications were deep infection (1.8%), deep vein thrombosis (0.9%), trochanteric osteotomy complications (1.8%), superficial infection (7.3%), urinary tract infection (5.5%), pressure sore (3.7%) and respiratory complication (1.8%). Fifteen hips (13.8%) required revision. The causes for revision were aseptic loosening, dislocation and infection. Technical anomalies were recognized as one of the factors contributing to poor results. Five-year survival rate was 87.3%. Better results can be expected with increasing experience and technical skulls.
  13. Narayanan SS, Suhail A, Harjeet S, Shahril Y, Masbah O
    Malays Orthop J, 2009;3(1):19-23.
    MyJurnal
    This study was conducted to evaluate the efficacy of intra-articular injection of hyaluronic acid for the treatment of knee osteoarthritis. Patients with knee osteoarthritis were followed for a period of six months to assess the efficacy of intra-articular injection of hyaluronic acid given three times in three consecutive weeks. Fifty patients were reviewed at two, eight and 24 weeks post-injection. The average age was 60.9 years and female to male ratio was 3:1. Patients were assessed using the Lequesne Algofunctional Index for function, and the visual analogue score for pain and side effects. We found that the knee pain reduced and the function improved in most patients and these beneficial effects maintained for till the last follow up. The only side effect noted was one case of acute non-septic joint effusion after the 3rd injection. We concluded that intra-articular injection of hyaluronic acid can produce pain relief and functional improvement for up to 6 months.
  14. Radhi AM, Masbah O, Shukur MH, Shahril Y, Taiman K
    Med J Malaysia, 2006 Feb;61 Suppl A:50-2.
    PMID: 17042230
    Orthopaedic procedures especially dynamic hip screw (DHS) fixation, interlocking nailing (ILN) of the tibia and femur require fluoroscopic assistance. Frequent exposure to radiation is a major concern to members of the orthopaedic surgical team. This study was undertaken to measure shallow (skin) dose to the operating team personnel and deep (whole body) dose to the surgeon during such procedures in view to provide guidelines to the operating team members regarding the number of procedures allowable for them to perform or assist annually. Skin dose for the operating personnel and whole body dose for the operating surgeon during 25 procedures; ten cases of DHS, seven and six cases of ILN of the tibia and femur respectively, was measured using Thermoluminescent Dosimeter (TLD) chips. The shallow radiation dose for theatre personnel ranged from 0.19 mSy to 0.61 per case while the deep dose for the surgeon was 0.28, 0.55 and 0.81 mSy for seven cases of tibial ILN, ten cases of DHS and six cases of femur ILN respectively. The surgeon has the highest radiation exposure than other theatre personnel and the whole body exposure for DHS was higher than that of for ILN. However, the estimated cumulative dose was still far below the permissible annual dose limit.
  15. Mohd Fuad D, Masbah O, Shahril Y, Jamari S, Norhamdan MY, Sahrim SH
    Med J Malaysia, 2006 Feb;61 Suppl A:27-9.
    PMID: 17042225
    Antibiotic-loaded bone cement has been used as prophylaxis against infection in total joint replacement surgery. Its effect on the mechanical strength of cement is a major concern as high dose of antibiotic was associated with a significant reduction in mechanical strength of bone cement. However, the cut-off antibiotic that weakens the mechanical strength of cement remains to be determined. This study was undertaken to observe the changes in the mechanical properties of bone cement with gradual increments of Cefuroxime antibiotic. Cefuroxime at different doses: 0, 1.5, 3.0 and 4.5gm were added to a packet of 40gm bone cement (Simplex P) and study samples were prepared by using third generation cementing technique. Mechanical impact, flexural and tensile strength were tested on each sample. Significant impact and tensile strength reduction were observed after addition of 4.5 gm of Cefuroxime. However, flexural strength was significantly reduced at a lower dose of 3.0 gm. The maximum dose of Cefuroxime to be safely added to 40mg Surgical Simplex P is 1.5gm when third generation cementing technique is used. Further study is needed to determine whether it is an effective dose as regards to microbiological parameters.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links