Displaying all 3 publications

Abstract:
Sort:
  1. Sidhu P, Shankargouda S, Dicksit DD, Mahdey HM, Muzaffar D, Arora S
    J Endod, 2016 Apr;42(4):622-5.
    PMID: 26850688 DOI: 10.1016/j.joen.2015.12.027
    INTRODUCTION: Use of mobile phone has been prohibited in many hospitals to prevent interference with medical devices. Electromagnetic radiation emitted from cellular phones might interfere with electronic working length determination. The purpose of this in vitro study was to evaluate the effect of a smart phone (Samsung Galaxy Note Edge) on working length determination of electronic apex locators (EALs) Propex II and Rootor.

    METHODS: Fifteen intact, non-carious single-rooted teeth were decoronated at the cementoenamel junction. Visually, working length was determined by using a #15 K-file under stereomicroscope (×20). The effect of cellular phones on electronic working length (EWL) was determined under 2 experimental settings: (1) in a closed room with poor signal strength and (2) in a polyclinic set up with good signal strength and 5 conditions: (1) electronically, without cellular phone in room; (2) electronically, with cellular phone in physical contact with EAL; (3) electronically, with mobile phone in physical contact with EAL and in calling mode for a period of 25 seconds; (4) electronically, mobile phone placed at a distance of 40 cm from the EAL; and (5) electronically, mobile phone placed at a distance of 40 cm and in calling mode for a period of 25 seconds. The EWL was measured 3 times per tooth under each condition. Stability of the readings was scored from 1 to 3: (1) good stability, (2) stable reading after 1 attempt, and (3) stable reading after 2 attempts. The data were compared by using analysis of variance.

    RESULTS: The EWL measurements were not influenced by the presence of cellular phone and could be determined under all experimental conditions.

    CONCLUSIONS: Within the limitations of this study, it can be concluded that mobile phones do not interfere with the EWL determination.

  2. Zain E, Talreja N, Hesarghatta Ramamurthy P, Muzaffar D, Rehman K, Khan AA, et al.
    Eur J Dent Educ, 2024 Feb;28(1):358-369.
    PMID: 37864324 DOI: 10.1111/eje.12957
    INTRODUCTION: Simulation-based education is of paramount importance in a dental pre-clinical setting. Hence, continuous quality improvement is crucial to optimize students' knowledge and clinical skills. This study aimed to evaluate the impact of evidence-based simulation learning (EBSL) compared with traditional-based simulation learning (TBSL) using Plan-Do-Study-Act (PDSA) model.

    MATERIALS AND METHODS: This quality improvement project was undertaken at a private university. Guided by the PDSA model, rubber dam application tasks were conducted in the simulation lab in 2 phases. Phase 1 included TBSL and phase 2 included EBSL comprising of 2 PDSA cycles. 'Plan' stage involved obtaining feedback from students and the concerned staff. 'Do' stage included implementation of EBSL in eight steps adopted from Higgins's framework. 'Study' stage evaluated the outcomes and in 'Act' stage amendments were made to the first EBSL cycle. In the second PDSA cycle re-implementation and evaluation of the rubber dam application exercises were carried out. Descriptive data were presented as percentages and mean scores were compared using paired t-test.

    RESULTS: Thirty-seven year 2 students participated in this study. A significant improvement in the mean scores was observed between TBSL and EBSL (3.02 + 0.16 and 3.91 + 0.27, respectively, p 

  3. Idrees QTA, Gul N, Fareed MA, Mian SA, Muzaffar D, Nasir M, et al.
    Materials (Basel), 2021 Dec 07;14(24).
    PMID: 34947103 DOI: 10.3390/ma14247507
    This study aimed to modify an EQUIA coat (EC; GC, Japan) by incorporating 1 and 2 wt.% of zinc oxide (ZnO; EC-Z1 and EC-Z2) and titanium dioxide (TiO2; EC-T1 and EC-T2) nanoparticles, whereby structural and phase analyses were assessed using Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD), respectively. Thermogravimetric analysis/differential scanning calorimetry, micro-hardness, and water absorption analyses were conducted, and the microstructure was studied by scanning electron microscopy/energy-dispersive spectroscopy. FTIR spectra showed a reduction in peak heights of amide (1521 cm-1) and carbonyl (1716 cm-1) groups. XRD showed peaks of ZnO (2θ ~ 31.3°, 34.0°, 35.8°, 47.1°, 56.2°, 62.5°, 67.6°, and 68.7°) and TiO2 (2θ ~ 25.3°, 37.8°, 47.9, 54.5°, 62.8°, 69.5°, and 75.1°) corresponding to a hexagonal phase with a wurtzite structure and an anatase phase, respectively. Thermal stability was improved in newly modified materials in comparison to the control group. The sequence of obtained glass transitions was EC-T2 (111 °C), EC-T1 (102 °C), EC-Z2 (98 °C), EC-Z1 (92 °C), and EC-C (90 °C). EC-T2 and EC-T1 showed the highest (43.76 ± 2.78) and lowest (29.58 ± 3.2) micro-hardness values. EC showed the maximum water absorption (1.6%) at day 7 followed by EC-T1 (0.82%) and EC-Z1 (0.61%). These results suggest that EC with ZnO and TiO2 nanoparticles has the potential to be used clinically as a coating material.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links