  1. Ahmad Sayuti Zainal Abidin, Leman, A.M., Nor Mohd Razif Noraini
    MyJurnal
    This study intended to investigate the level on airborne microbe in indoor air for new constructed building. It was divided by three different phase of building commissioning in Bandar Baru Bangi, Selangor. The first phase of the sampling was carried out after the building fully handed over from the main contractor to the building owner. Second phase of the sampling take place after the building is equipped with furniture. Phase three sampling is conducted after one month of building occupancy. Airborne microbes’ concentrations were determined by using a single stage impactor (Biosampler) as per requirement of National Institute of Occupational Safety and Health (NIOSH) method, NIOSH Manual Analytical Method MAM 0800. The total concentration of airborne bacteria and fungi were average to 641 and 38 CFU/m³ in the first phase, 133 and 117 CFU/m³ in the second phase, and 389 and 52 CFU/m³ in the third phase. These findings indicate that although a new constructed building should be having a significant background level of airborne microbe (total bacteria and total fungi). The building owner should be aware to their indoor air status to protect the occupant from the safety and health problem (risk) especially for ventilated building.
  2. Nor Mohd Razif Noraini, Leman, A.M., Ahmad Sayuti Zainal Abidin
    MyJurnal
    A preliminary study has been conducted in a new constructed 8 stories building (2 level of Hostels facility, 3 level of Training Room, 2 Level of Offices and 1 level of Exhibition Halls and Rooms) in Bandar Baru Bangi, Selangor. The Hostels facility is a floor tile and furnished with build in locker and use split air conditioning system while the Training Room and Exhibition Rooms used floor tile. The Offices and Exhibition Hall are carpeted furnished. All these spaces were using centralized air conditioning systems. A pre-commissioning assessment on 5 chemical parameters of indoor air pollutants such Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM!
  3. Ahmad Sayuti Zainal Abidin, Leman, A.M., Nor Mohd Razif Noraini
    MyJurnal
    This study was done to investigate the background level on microbiological indoor air pollutants in new constructed 8 stories buildings (2 level of Hostel facilities, 3 level of Training Room level, 2 level of Offices and 1 Exhibition Halls and Rooms) in Bandar Baru Bangi, Selangor. The offices and exhibition hall are carpeted furnished. All these spaces were using centralized air conditioning system. Airborne microbes’ concentrations were determined by using a single stage impactor (Biosampler) as per requirement of National Institute of Occupational Safety and Health NIOSH method NIOSH Manual Analytical Method MAM 0800. Mean concentration of total bacteria detected is 1351 CFU/m3 and it was found significantly higher compared to maximum exposure limit 500 CFU/m3 in office room. The mean concentration of total fungi in the office rooms is 479 CFU/m3 and it was found slightly lower compared to maximum exposure limit 500 CFU/m3. The airborne microbe levels were found slightly lower in the accommodation, training and exhibition rooms compared to office room. These findings indicate that although a new constructed building should be having a significant background level of airborne microbe (total bacteria and total fungi).
  4. Nor Mohd Razif Noraini, Leman, A.M., Ahmad Sayuti ZainalAbidin, Ruslina Mohd. Jazar, LailaShuhada Mat Zin, Rasdan Ismail, et al.
    MyJurnal
    This study has been conducted in a new constructed building of NIOSH Malaysia located at Bandar Baru Bangi, Selangor. The goal of the case study is focusing on the level of Indoor Air Contaminants (IAC) including chemical contaminants within three consequent stages which are before furniture install, after furniture install and during one month occupancy. This study was divided the sampling area into two main facilities which are training and office setting. The contaminants has been measured consist of sixparameters such as Carbon Dioxide (CO2), Carbon Monoxide (CO), Total Volatile Organic Compounds (TVOC), Formaldehyde, Respirable Particulates (PM10) and Ozone. The result of Carbon Monoxide (CO), Total Volatile Organic Compound (TVOC), Respirable Particulates (PM10) and Ozone show an increasing trend across the three sampling stages. The Formaldehyde show an increasing trend in the first and second stages but were reduced significantly the last stage of sampling. These finding indicates that furniture and fittings installed might be a potential sources of indoor air contaminants. The management should be aware to their indoor air status to protect the occupant from the risk of unwanted exposure especially during the early stage of building occupancy.