METHODS: Corneal thickness was measured at the central and mid-peripheral locations of 20 participants aged 22.45±1.19 years using Tomey SP-3000 A-scan ultrasonography. Endothelial images of the central and peripheral locations captured using Tomey EM-3000 specular microscope were noted. Corneal thickness, endothelial cell density (ECD), coefficient of variation in cell size (CV), and hexagonality (HEX) at baseline, 24 hours, three months and six months after treatment were noted and analysed using repeated measure analysis of variance.
RESULTS: Central corneal thickness decreased significantly over a three-month period (p=0.001) and stabilised thereafter. There were no significant changes in thickness in all peripheral areas measured (p>0.05), and in ECD, CV and HEX after the six-month period (p>0.05).