Displaying publications 1 - 20 of 43 in total

Abstract:
Sort:
  1. Patil PG, Nimbalkar-Patil S
    J Prosthodont, 2017 Jul;26(5):481-482.
    PMID: 26683255 DOI: 10.1111/jopr.12425
    Various tools are used with a dental surveyor, including analyzing rods, carbon markers, undercut gauges, and protective sheaths for a specific function. A carbon marker is a parallel-sided carbon rod used to mark the survey line on a cast or a crown on a cast. The carbon marker (with or without protective sheath) cannot differentiate more than one survey line on the cast if needed. The wear of the carbon marker along the parallel walls after repeated use may give an incorrect survey line. We suggest a simple modification in the analyzing rod to prepare a two-colored surveying tool. An analyzing rod is a parallel-sided rod used to analyze the relative parallelism of two or more surfaces of a cast and to mark survey lines on wax patterns. With the modified analyzing rod, the survey lines can be marked with two colors, and the problem of breaking of the carbon marker also can be eliminated.
  2. Patil PG, Nimbalkar-Patil S
    Contemp Clin Dent, 2015 Jul-Sep;6(3):318-20.
    PMID: 26321828 DOI: 10.4103/0976-237X.161869
    Recording of the maxillomandibular relationship (MMR) in implant complete arch restorations usually necessitates removal of the healing abutments to attach the record bases, which makes the procedures tedious and time-consuming.
  3. Patil PG, Nimbalkar-Patil S
    J Am Dent Assoc, 2015 May;146(5):287-8.
    PMID: 25925512 DOI: 10.1016/j.adaj.2015.03.004
  4. Patil PG, Seow LL
    J Prosthet Dent, 2020 May;123(5):710-716.
    PMID: 31558274 DOI: 10.1016/j.prosdent.2019.07.015
    STATEMENT OF PROBLEM: Single-implant-retained overdentures are an alternative treatment option for an edentulous mandible. However, evaluation of their clinical performance with an immediate loading protocol is lacking.

    PURPOSE: The purpose of this prospective randomized controlled clinical study was to evaluate crest bone-level changes and patient satisfaction with mandibular overdentures retained by 1 or 2 titanium-zirconium (Ti-Zr) implants with immediate loading protocols after 1 year.

    MATERIAL AND METHODS: Thirty-six Ti-Zr implants were placed in 24 participants (single central implant in 12 participants and 2 interforaminal implants in 11 participants) by a single operator. LOCATOR attachments were used to retain the mandibular overdentures with an immediate loading protocol, and observations were made at 1 month and 1 year. Changes to the crestal bone level were evaluated with digital periapical radiographs. A 100-mm visual analog scale (VAS) was used to evaluate patient satisfaction. The Mann-Whitney U test was used to analyze the data.

    RESULTS: At 1 month, the mean crestal bone loss was 0.23 mm in the 2-implant group (n=22) and 0.39 mm (P=.181) in the single-implant group (n=11). At 1 year, the bone loss was 0.67 mm in the 2-implant group and 0.88 mm (P=.248) in the single-implant group. The mean VAS score for patient satisfaction level increased from 38.3% to 49.7% for single-implant participants and from 40.5% to 54.8% for 2-implant participants 1 month after implant placement (P=.250) and from 38.3% to 54.5% for single-implant participants and from 40.5% to 58.9% for 2-implant participants after 1 year (P=.341).

    CONCLUSIONS: Single-implant-retained mandibular overdentures with an immediate loading protocol may represent a viable treatment option considering crestal bone-level changes and patient satisfaction compared with 2-implant-retained mandibular overdentures after 1 year of follow-up.

  5. Voon YS, Patil PG
    J Prosthet Dent, 2018 Apr;119(4):568-573.
    PMID: 28838820 DOI: 10.1016/j.prosdent.2017.05.011
    STATEMENT OF PROBLEM: The genial tubercle is a clinically palpable landmark in the mandible and can be identified in cone beam computed tomography (CBCT). Its location can be used to measure the safe zone in the interforaminal region of the mandible. These measurements may be helpful for implant treatment planning in patients with complete edentulism.

    PURPOSE: The purpose of this clinical study was to evaluate the safe distance in the interforaminal region of the mandible measured from the genial tubercle level for implant osteotomy in a Chinese-Malaysian population.

    MATERIAL AND METHODS: A total of 201 Digital Imaging and Communications in Medicine (DICOM) files were selected for the study from the CBCTs of dentate or edentulous Chinese-Malaysian adult patients with ongoing or completed treatments. Measurements were made with implant planning software. The anatomy of the whole mandible was assessed in the coronal cross-sectional, horizontal view and in panoramic view. Measurements were obtained in millimeters on one side by locating and marking a genial tubercle and then marking the mesial margin of the mental foramen and the anterior loop of the inferior alveolar nerve. The corresponding points of these landmarks were identified on the crest of the mandibular ridge to measure the linear distances. All the measurement steps were repeated on the other side. The linear distance of 2 mm was deducted from the total distance between the genial tubercle and the anterior loop separately for left and right side measurements to identify the safe zone. The mixed 2-way analysis of variance (ANOVA) test was used to analyze side and sex-related variations.

    RESULTS: The mean safe zone measured at the crestal level from the genial tubercle site on the left side of the mandible was 21.12 mm and 21.67 mm on the right side. A statistically significant (P

  6. Wong SK, Patil PG
    J Prosthet Dent, 2018 Aug;120(2):210-213.
    PMID: 29551376 DOI: 10.1016/j.prosdent.2017.10.019
    STATEMENT OF PROBLEM: The inferior alveolar nerve (IAN) frequently loops backward before exiting from the mental foramen and spreads several millimeters medially to the foramen. Implant placement in this area may damage the nerve if the anterior loop area is not carefully identified in a radiographic or computed tomography (CT) evaluation.

    PURPOSE: The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population.

    MATERIAL AND METHODS: A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05).

    RESULTS: The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women.

    CONCLUSIONS: The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations.

  7. Foong KW, Patil PG
    Saudi Dent J, 2019 Jan;31(1):148-154.
    PMID: 30705578 DOI: 10.1016/j.sdentj.2018.10.007
    Construction of a single complete denture (SCD) is a challenging clinical situation especially when the opposing natural dentition is not in a normal plane of occlusion. Mal-aligned, tilted or supra-erupted teeth in the opposing arch are some of the problems that should be corrected to achieve a balanced occlusion in patients who require SCD. Achieving harmonious occlusal plane is a primary objective of any restorative procedure to facilitate natural mandibular movements and ease of mastication. Establishment of normal occlusal plane in opposite arch is pre-requisite to maintain the stability of the SCD. This clinical report describes restoration of mandibular teeth (with severe attrition and deranged occlusion) by establishing normal plane of occlusion with the help of custom made occlusal plane template (OPT) followed by construction of a complete denture in maxillary arch.
  8. Patil PG, Lim HF
    J Prosthet Dent, 2023 Jul;130(1):14-18.
    PMID: 34774303 DOI: 10.1016/j.prosdent.2021.08.005
    Fabricating a new crown to retrofit with an existing removable partial denture (RPD) is a complex procedure for both clinician and dental laboratory technician. The presented technique facilitates the fabrication and retrofitting of a metal-ceramic crown onto the principal abutment of the existing RPD by using 2-step intraoral scanning (with and without the RPD in place) and 2 different 3-dimensionally printed casts. The technique enables the dental laboratory technician to precisely reproduce the retentive areas, guiding planes, and rest seats on the retrofitted crown.
  9. Patil PG, Nimbalkar-Patil S
    J Indian Prosthodont Soc, 2015 Oct-Dec;15(4):337-41.
    PMID: 26929537 DOI: 10.4103/0972-4052.161568
    INTRODUCTION: The maxillomandibular relationship (MMR) record is a critical step to establish the new occlusion in implant supported complete mouth rehabilitation. Using patients existing denture for recording the MMR requires implant definitive cast to be modified extensively to completely seat the denture (with unaltered flanges) on it. This may influence the correct seating of the denture on the implant definitive cast causing faulty recording of the MMR.
    MATERIALS AND METHOD: Elastomeric record bases, reinforced with the resin framework, are fabricated and relined with the light body elastomeric material when all the healing abutments are in place. The MMR is recorded with these elastomeric record bases using vacuum formed facial surface index of the occluded existing dentures as a guideline.
    RESULTS: The elastomeric record bases with facial surface index of the existing dentures can allow clinicians to record MMR records without removing the healing abutments from the mouth with acceptable accuracy. This can save chair-side time of the procedure. The record of facial surfaces of existing complete denture in the form of vacuum formed sheet helps to set the occlusal vertical dimension.
    CONCLUSION: Use of facial surface index together with the elastomeric record bases can be the useful alternative technique to record the MMR in patients with implant supported full mouth rehabilitation. Further study is required to prove its routine clinical utility.
    KEYWORDS: Implant restorations; maxillomandibular relation; occlusion rim; record base
  10. Patil PG, Nimbalkar-Patil S
    J Indian Prosthodont Soc, 2017 2 22;17(1):84-88.
    PMID: 28216851 DOI: 10.4103/0972-4052.176538
    INTRODUCTION: Maxillary obturator prosthesis is more frequent treatment modality than surgical reconstruction for maxillectomy in patients suffering from oral cancer. The obturators often become heavy and hence are hollowed out in the defect portion to reduce its weight as a standard practice.

    MATERIALS AND METHODS: The processing technique described the incorporation of the preshaped "wax-bolus" during packing procedure of the Obturtor prosthesis and eliminated later by melting it once the curing procedure is completed.

    RESULTS: This article is a single step procedure resulting into the closed-hollow obturator as single unit with uniform wall thickness around the hollow space ensuring the least possible weight of the hollow obturator.

    CONCLUSION: This processing technique achieves predictable internal dimension of the hollow space providing uniform wall thickness of the obturator.

  11. Patil PG, Seow LL
    J Indian Prosthodont Soc, 2021 11 24;21(4):375-382.
    PMID: 34810365 DOI: 10.4103/jips.jips_328_21
    Aim: Single implant-retained mandibular overdentures (1IMO) is a viable alternative to 2 implant-retained overdentures (2IMO) in edentulous patients. However, literature lacks in the quality of life (QoL) of these patients when treated with immediate loading protocols. The purpose of this study was to compare oral health-related QoL (OHRQoL) of patients using 1IMO or 2 IMO with immediate loading protocols at 1 month and 1 year.

    Settings and Design: Randomized Controlled Trial.

    Materials and Methods: Fifty-two edentulous participants treated with mandibular overdentures using either single implant (n = 26) or two implants (n = 26) with immediate loading protocol by a single operator. The low-profile stud-attachments (LOCATOR; Zest Anchors) were attached to the implants and female attachments were picked up within 0-7 days of implant placement. The OHRQoL was recorded using Oral Health Impact Profile-14 (OHIP-14) questionnaire either in English or in the Malay language before treatment and 1 month and 1 year after treatment.

    Statistical Analysis Used: Kruskal Wallis test was used to find out significant difference amongst 3 timepoints and 7 OHIP-14 domains and Mann-Whitney-U test to compare 1IMO or 2IMO groups.

    Results: Compared to baseline OHIP-14 scores, participants had a statistically significant decrease in total OHIP-14 at 1 month and 1 year after-treatment time points in both 1IMO and 2IMO groups (P < 0.05). The difference between 1 month and 1 year after-treatment total and subscale scores were also found to be statistically significant (P < 0.05). The overall QoL improvement was comparatively higher in 2IMO group than 1IMO group. The OHIP-14 scores were statistically different within seven domains (P < 0.05). Overall total scores between 1IMO and 2IMO groups were also found to be statistically significant (P < 0.05) at baseline and insignificant (P > 0.05) at 1 month and 1 year.

    Conclusions: Mandibular single and 2IMO improve the QoL of elderly edentulous Malaysian participants at 1 month of immediate loading and 1 year of recall. 1IMO may provide comparable QoL with the elderly patients using 2 implants.

  12. Patil PG, Nimbalkar-Patil S
    Case Rep Dent, 2016;2016:4618510.
    PMID: 27843652
    Patient. A 68-year-old man was operated on for squamous cell carcinoma (T3N3M0) of the maxilla creating the hemimaxillary surgical defect on right side. The remaining arch was completely edentulous. There was remarkable limitation in the oral opening with reduced perimeter of the oral cavity due to radiation and surgical scar contracture. This article describes prosthetic rehabilitation by modifying the design of the obturator and achieving the retention with dental implant. Discussion. Severe limitation in the oral opening may occur in clinical situations following the postsurgical management of oral and maxillofacial defects. The prosthetic rehabilitation of the surgical defect in such patients becomes a challenging task due to limited access to the oral cavity. This challenge becomes even more difficult if the patient is edentulous and there are no teeth to gain the retention, stability, and support. Conclusion. In severe microstomia prosthesis insertion and removal can be achieved with modification of the maximum width of the prosthesis. Dental implant retention is useful treatment option in edentulous patients with maxillary surgical defect provided that sufficient bone volume and accessibility are there for implant placement.
  13. Patil PG, Seow LL
    J Prosthet Dent, 2022 Nov 18.
    PMID: 36411113 DOI: 10.1016/j.prosdent.2022.09.007
    STATEMENT OF PROBLEM: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with an edentulous mandible, but information on the effect of the optimum implant position on the peri-implant crestal bone level with immediate loading protocols is lacking.

    PURPOSE: The purpose of this prospective clinical study was to evaluate correlations between different implant positions and crestal bone loss and between interimplant distance and the crestal bone loss in patients with 2IMOs with immediate loading protocols at 1-year follow-up.

    MATERIAL AND METHODS: A total of 24 participants (13 men, 11 women, mean ±standard deviation age 63.25 ±10.76 years) were treated with 2IMOs (48 Ti-Zr implants) by a single operator between August 2015 and October 2020. The implant diameters (3.3 mm or 4.1 mm) and lengths (10 mm or 12 mm) were selected based on the crestal bone width, and the implants were placed, if possible, in the canine regions. Implant positions and interimplant distance (mm) were measured intraorally with dividers. Prefabricated mandibular dentures were immediately loaded with the LOCATOR-attachments by using a direct intraoral pickup procedure. Crestal bone-level changes were measured with a software program on the mesial and distal sides of each implant from periapical radiographs made with a paralleling technique (at baseline and 1-year follow-up). The measurement values were normalized. The Spearman rho correlation test and paired samples t tests were used for data analysis (α=.05).

    RESULTS: The mean ±standard deviation position of the implants from the midline was 8.78 ±2.25 mm (9.00 ±2.22 mm right side, 8.56 ±2.31 mm left side), and the mean interimplant distance was 16.94 ±4.03 mm. At 1-year follow-up, the mean ±standard deviation crestal bone loss was 0.50 ±0.47 mm (n=48) (0.57 ±0.65 mm mesial, 0.43 ±0.53 mm distal). The mean ±standard deviation crestal bone loss was 0.46 ±0.4 mm with Ø3.3-mm implants (n=42) and 0.9 ±0.8 mm with Ø4.1-mm implants (n=6) (P=.005). Implant positions were negatively correlated (rs=-0.37) with the crestal bone loss, and the correlation was significant (P=.009). Interimplant distances were also negatively correlated with crestal bone loss (rs=-0.60; P=.002). Bone loss on the mesial side was positively correlated with that on the distal side rs=0.20; however, the correlation was not significant (P=.16).

    CONCLUSIONS: A weak and negative correlation was found between the implant position from the midline and the crestal bone loss and also between the interimplant distance and crestal bone loss in patients provided with 2IMOs with immediate loading protocols.

  14. Patil PG, Nimbalkar-Patil SP
    J Prosthodont, 2018 Mar;27(3):314-316.
    PMID: 27333596 DOI: 10.1111/jopr.12491
    Accurate planning for the framework design of removable partial dentures requires careful analysis of the diagnostic cast with a dental surveyor to determine the optimal path of placement. Some techniques described in the literature are helpful in reorienting the same cast on the surveyor, including the tripod marking method; however, there is a possibility of introducing human errors during marking and repositioning of the tripod points on to the different casts at the same location. Other techniques, which do not require markings on the cast to reorient different casts of the same patient, need specific devices or trays. This article suggests the direct use of a putty-elastomeric orientation index that can be preserved and used multiple times while reorienting different casts of the same patients at various laboratory steps. A putty elastomeric impression material is mixed and adapted on to the diagnostic cast, covering key teeth areas of the cast and incorporating the analyzing rod of the surveyor. Thus there is no need to use a special device or the tray to reorient different casts.
  15. Patil PG, Nimbalkar-Patil SP
    J Prosthodont, 2018 Jan;27(1):94-97.
    PMID: 27002917 DOI: 10.1111/jopr.12464
    Bilateral cleft lip/cleft palate is associated with nasal deformities typified by a short columella. The presurgical nasoalveolar molding (NAM) therapy approach includes reduction of the size of the intraoral alveolar cleft as well as positioning of the surrounding deformed soft tissues and cartilages. In a bilateral cleft patient, NAM, along with columellar elongation, eliminates the need for columellar lengthening surgery. Thus the frequent surgical intervention to achieve the desired esthetic results can be avoided. This article proposes a modified activation technique of the nasal stent for a NAM appliance for columellar lengthening in bilateral cleft lip/palate patients. The design highlights relining of the columellar portion of the nasal stent and the wire-bending of the nasal stent to achieve desirable results within the limited span of plasticity of the nasal cartilages. With this technique the vertical taping of the premaxilla to the oral plate can be avoided.
  16. Kher U, Tunkiwala A, Patil PG
    J Prosthet Dent, 2022 Jan;127(1):6-14.
    PMID: 33243475 DOI: 10.1016/j.prosdent.2020.09.023
    Implant-supported fixed prostheses in the edentulous maxilla can be difficult because of anatomic limitations and high esthetic demand. The choice between cement and screw retention depends on factors such as esthetics, occlusion, retrievability, and passivity. The choice is also often governed by the ability to manage technical or biologic complications. In the edentulous maxilla, because of the bone trajectory and resorption pattern, unfavorable implant angulations may be encountered. In such situations, a conventional screw-retained prosthesis is difficult to design. This article describes the restoration of edentulous maxillae for a series of patients with different complete-arch fixed prosthesis designs. The clinical guidelines, including indications, advantages, and limitations of each design, were discussed.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links