Displaying all 5 publications

Abstract:
Sort:
  1. Mohamad Hasyizan Hassan, Eng, Ming Fung, Rhendra Hardy Mohd Zaini, Shamsul Kamalrujan Hassan, Seevaunnamtum, Praveena, Mohd Zulfakar Mazlan, et al.
    MyJurnal
    Background: Existing techniques of predicting difficult laryngoscopy are inadequate requiring evaluation of Maxillopharyngeal Angle (MP-A) on lateral cervical radiograph described. Objectives: This study aimed to compare MP-A test with Modified Mallapati Test (MMT) in predicting their diagnostic values and Area Under Curve of Receiver Operating Characteristic Curve (AUCROCC) of both test. Methods: This is a double blinded interventional study of 93 patients. Each patient’s MMT score was assessed during preoperative assessment and subsequent MP-A test done by obtaining lateral cervical radiograph with the head in neutral position. Laryngeal view was assessed using Cormack-Lehane grade after induction of anesthesia, was used as reference standard to determine the diagnostic values of MMT and MP-A respectively. Results: The MP-A compared to MMT in predicting difficult larngoscopy had higher sensitivity (77.78 vs 44.44) specificity (88.10 vs 67.86) and accuracy (87.10 vs 65.59) with higher Odd Ratio(26.12 vs 1.68). The AUCROCC was significantly higher in MP-A test 0.83(95%CI: 0.67, 0.99) (P = 0.001) vs MMT 0.56(95%CI: 0.36, 0.76) (P = 0.546) with LR+ of 6.53 vs 1.38. Conclusion: The Maxillopharyngeal Angle test was superior in predicting difficult laryngoscopy as compared to Modified Mallampati Test.
  2. Kumar Sinasamy T, Nazaruddin Wan Hassan WM, Hardy Mohamad Zaini R, Seevaunnamtum P, Ab Mukmin L
    Anaesthesiol Intensive Ther, 2020;52(5):383-388.
    PMID: 33327696 DOI: 10.5114/ait.2020.101407
    INTRODUCTION: The Baska mask and i-gel are two new types of second-generation supraglottic airway devices. The aim of this study was to compare these two devices in terms of quality of insertion, quality of ventilation and post-insertion complications.

    MATERIAL AND METHODS: A total of 80 adult patients who were scheduled for elective surgery under general anaesthesia were randomised to two groups: Group BM: Baska mask (n = 40) and Group IG: i-gel (n = 40). The assessment focused on ease of insertion, number of attempts, insertion time, number of corrective manoeuvres, oropharyngeal leak pressure, tidal volume, peak airway pressure (PAP) and post-insertion complications.

    RESULTS: Group IG showed a significantly shorter median insertion time (13.3 [interquartile range, IQR 7.8] vs. 17.0 [IQR 9.6] s; P < 0.001), a higher percentage in the 'very easy' ease of insertion category (62.5% vs. 10.0%; P < 0.001), a higher percentage in the no corrective manoeuvre category (92.5% vs. 72.5%; P = 0.003) and a higher percentage in the no post-operative throat pain category (67.5% vs. 32.5%; P = 0.011) than Group BM. However, Group BM showed a significantly higher generated PAP than Group IG (12.7 [1.8] and 11.5 [2.2] cm H2O, respectively; P = 0.010). There were no significant differences in other parameters.

    CONCLUSIONS: The i-gel was better than the Baska mask in terms of ease of insertion, speed of insertion, fewer corrective manoeuvres and less post-operative throat pain. However, the Baska mask had a better cuff seal, as shown by a higher generated PAP.

  3. Narhari R, Nazaruddin Wan Hassan WM, Mohamad Zaini RH, Che Omar S, Abdullah Nik Mohamad N, Seevaunnamtum P
    Anaesthesiol Intensive Ther, 2020;52(5):377-382.
    PMID: 33327695 DOI: 10.5114/ait.2020.101387
    INTRODUCTION: The choice of endotracheal tube (ETT) is important for successful orotracheal fibreoptic intubation (OFI). The aim of this study was to compare the use of the Parker flex tip (PFT) with the unoflex reinforced (UFR) ETT during OFI.

    MATERIAL AND METHODS: A total of 58 patients who underwent elective surgery under general anaesthesia were randomised to two ETT groups, the PFT group (n = 29) and the UFR group (n = 29), for OFI in simulated difficult intubation patients using a rigid cervical collar. After successful standardised induction and relaxation, OFI and railroading of selected ETT were subsequently performed by a similarly experienced practitioner. Ease of insertion, degree of manipulation, time to successful intubation, post-intubation complications and haemodynamic changes were recorded for both groups.

    RESULTS: he percentage of easy intubation was comparable between both groups with a slightly higher percentage in the UFR group than the PFT group (69.0% vs. 62.0%; P = 0.599). Degree of manipulation was also comparable between the two groups; the percentage of cases in which manipulation was not required was slightly higher in the UFR group than the PFT group (69.0% vs. 62.1%; P = 0.849). Time to successful intubation was also comparable between the groups, although the time was slightly shorter for the UFR group than the PFT group (56.9 s ± 39.7 s vs. 63.9 s ± 36.9 s; P = 0.488). There were also no significant differences in other parameters.

    CONCLUSIONS: The Parker flex tip ETT was comparable to the unoflex reinforced ETT for OFI in simulated difficult airway patients.

  4. Hassan SK, Wong PC, Seevaunnamtum P, Che Omar S, Nik Mohamad NA
    Malays J Med Sci, 2024 Jun;31(3):117-124.
    PMID: 38984244 DOI: 10.21315/mjms2024.31.3.8
    BACKGROUND: Phenylephrine (PE) is one of the vasopressor used to treat hypotension during anaesthesia. The primary aim of this study was to compare the effect of prophylactic infusion and rescue bolus of PE on the haemodynamic changes during spinal anaesthesia (SA) for Caesarean section (CS) in obese parturients.

    METHODS: A total of 74 obese parturients scheduled for elective CS under SA were randomised into two groups; Group A (n = 37) received prophylactic PE infusion starting at 50 μg min-1 and adjusted according to the given algorithm and Group B (n = 37) received 100 μg PE bolus to treat hypotension. The measured parameters were systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), the total requirement of PE and neonatal Apgar score.

    RESULTS: Six patients were excluded from the analysis due to missing data and only 68 were analysed. Group A showed significantly higher SBP, DBP and MAP than Group B (P < 0.05). The requirement of PE was higher in Group A than Group B [817.7 (265.7) μg versus 360.6 (156.0) μg; P = < 0.05]. Both groups had no difference in terms of the neonatal Apgar score.

    CONCLUSION: Prophylactic PE infusion provided better haemodynamic control than therapeutic boluses in obese parturients undergoing CS under SA.

  5. Mohd Ariff NA, Mazlan MZ, Mat Hassan ME, Seevaunnamtum PA, Wan Muhd Shukeri WF, Nik Mohamad NA, et al.
    Respir Med Case Rep, 2018;23:93-95.
    PMID: 29387523 DOI: 10.1016/j.rmcr.2018.01.001
    Introduction: Bronchoscopy is a commonly used procedure in the context of aspiration in the Intensive Care Unit setting. Despite its ability to remove mucus plug and undigested gastric contents, aspiration of gastric content into the trachea is one of the most feared complications among anesthesiologist.

    Discussion: The scenario is made worst if the aspiration causes acute hypoxemic respiratory failure immediately post intubation. However, in the event of desaturation, the quick decision to proceed with bronchoscopy is a challenging task to the anesthesiologist without knowing the causes.

    Case presentation: We present a case of a 12-year-old boy who had a difficult-to-ventilate scenario post transferring and immediately connected to ventilator in operation theatre (OT) from portable ventilator from the emergency department. She was successfully managed by bronchoscopy.

    Conclusion: Special attention should be given to the difficult-to-ventilate scenario post intubation of traumatic brain injury patient prior to operation. Prompt diagnosis and bronchoscope-assisted removal of foreign body was found to be a successful to reduce morbidity and mortality.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links