The effect of room temperature ionic liquid (RTIL) on the formation of the fluorescence ternary complex oxalate-sodium morin-5-sulfonate (NaMSA)-Aluminium(III) has been studied. In weakly acidic medium and in the presence of RTIL, 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM-PF6), total complex formation is achieved as compared with the formation of the binary complex of NaMSA-Aluminium(III). The fluorescence characteristics of the system allowed the establishment of a very sensitive method for the spectrofluorimetric determination of oxalate ion. The ternary complex formed its highest fluorescence signal at 513 nm and excitation at 420 nm. In these conditions, the method produces a detection limit of 0.57 ng mL(-1). The procedure has been satisfactorily applied to the determination of oxalate ion in a vegetal tissue (spinach leaves).
A novel approach for the determination of Al(3+) from aqueous samples was developed using an optode membrane produced by physical inclusion of Al(3+) selective reagent, which is morin into a plasticized poly(vinyl chloride). The inclusion of Triton X-100 was found to be valuable and useful for enhancing the sorption of Al(3+) ions from liquid phase into the membrane phase, thus increasing the intensity of optode's absorption. The optode showed a linear increase in the absorbance at λ(max)=425 nm over the concentration range of 1.85×10(-6)-1.1×10(-4) mol L(-1) (0.05-3 μg mL(-1)) of Al(3+) ions in aqueous solution after 5 min. The limit of detection was determined to be 1.04×10(-6) mol L(-1) (0.028 μg mL(-1)). The optode developed in the present work was easily prepared and found to be stable, has good mechanical strength, sensitive and reusable. In addition, the optode was tested for Al(3+) determination in lake water, river water and pharmaceutical samples, which the result was satisfactory.
This paper reports the use of a polymer inclusion membranes (PIMs) for direct determination of Al(III) ions in natural water by using a fluorescence based optode. The best composition of the PIMs consisted of 60 wt.% (m/m) poly (vinyl chloride) (PVC) as the base polymer, 20 wt.% (m/m) triton X-100 as an extractant, 20 wt.% (m/m) dioctyl phthalate (DOP) as plasticizer and morin as the reagent, was used in this study. The inclusion of triton X-100 was used for enhancing the sorption of Al(III) ions from liquid phase into the membrane phase, thus increasing the optode fluorescence intensity. The optimized optode was characterized by a linear calibration curve in the range from 7.41 × 10(-7) to 1.00 × 10(-4) molL(-1) of Al(III), with a detection limit of 5.19 × 10(-7) molL(-1). The response of the optode was 4 min and reproducible results were obtained for eight different membranes demonstrated good membrane stability. The optode was applied to the determination of Al(III) in natural water samples. The result obtained is comparable to atomic absorption spectrometry method.
This paper describes the synthesis of poly(1-aminonaphthalene) and its application as a chemosensor for detection of Fe3+ using the naked eye and a fluorimetric method. The conjugated polymer was synthesized by chemical oxidative polymerization using FeCl3 as a catalyst. The response of the polymer towards various metal ions was investigated using colorimetric detection, and ultraviolet-visible and fluorescence spectroscopies. The polymer displayed high selectivity and sensitivity towards Fe3+ compared with other metal ions. A significant colour change from purple to yellow was observed upon addition of Fe3+ by the naked eye. The polymer also showed a high selectivity and sensitivity 'turn-off' fluorescence response towards Fe3+ ions. A good linear response was obtained for Fe3+ concentrations in the range 10-50 mg L-1 with a detection limit of 1.04 mg L-1 . The proposed chemosensor was applied for determination of Fe3+ content in water samples and satisfactory results were obtained.
Morin dye is known as a cheap and readily available selective 'off → on' fluorescent sensitiser when immobilised in a phase transfer membrane for the detection of Al3+ ions. Here, a morin derivative, NaMSA, which readily dissolves in water with good long-term stability is used in conjunction with a fibre optic transducer with lock-in detection to detect Al3+ in drinking water below the potability limit. The combination of a water soluble dye and the fibre optic transducer require neither membrane preparation nor a fluorescence spectrometer yet still display a high figure-of- merit. The known ability to recover morin-based Al3+ cation sensors selectively by exposure to fluoride (F-) anions is further developed enabling a complementary sensing of either fluoride anions, or aluminium cations, using the same dye with a sub-micromolar limit-of-detection for both ions. The sensor performance parameters compare favourably to prior reports on both aqueous aluminium and fluoride ion sensing.