METHODS: Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance.
RESULTS: Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method.
CONCLUSION: This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients.
KEY POINTS: • Clinical experience on liver thermal ablation using CT-guided robotic system is reported. • The technical success, radiation dose, safety and performance level were assessed. • Thermal ablations were successfully performed, with an average performance score of 4.4/5.0. • Robotic-assisted ablation can potentially increase capabilities of less skilled interventional radiologists. • Cost-effectiveness needs to be proven in further studies.
METHODS: We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions).
RESULTS/CONCLUSION: Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff.
KEY POINTS: • An early experience of robotic-assisted radiofrequency ablation is reported • Robotic-assisted RFA improves accuracy of hepatic lesion targeting • Robotic-assisted RFA makes the procedure technically easier with significant lower radiation dose.
METHODS: Anatomical MRI and structural DTI were performed cross-sectionally on 26 normal children (newborn to 48 months old), using 1.5-T MRI. The automated processing pipeline was implemented to convert diffusion-weighted images into the NIfTI format. DTI-TK software was used to register the processed images to the ICBM DTI-81 atlas, while AFNI software was used for automated atlas-based volumes of interest (VOIs) and statistical value extraction.
RESULTS: DTI exhibited consistent grey-white matter contrast. Triphasic temporal variation of the FA and MD values was noted, with FA increasing and MD decreasing rapidly early in the first 12 months. The second phase lasted 12-24 months during which the rate of FA and MD changes was reduced. After 24 months, the FA and MD values plateaued.
CONCLUSION: DTI is a superior technique to conventional MR imaging in depicting WM maturation. The use of the automated processing pipeline provides a reliable environment for quantitative analysis of high-throughput DTI data.
KEY POINTS: Diffusion tensor imaging outperforms conventional MRI in depicting white matter maturation. • DTI will become an important clinical tool for diagnosing paediatric neurological diseases. • DTI appears especially helpful for developmental abnormalities, tumours and white matter disease. • An automated processing pipeline assists quantitative analysis of high throughput DTI data.
METHODS: 3-T brain MRI and DTI (diffusion tensor imaging) were performed on 26 PD and 13 MSA patients. Regions of interest (ROIs) were the putamen, substantia nigra, pons, middle cerebellar peduncles (MCP) and cerebellum. Linear, volumetry and DTI (fractional anisotropy and mean diffusivity) were measured. A three-node decision tree was formulated, with design goals being 100 % specificity at node 1, 100 % sensitivity at node 2 and highest combined sensitivity and specificity at node 3.
RESULTS: Nine parameters (mean width, fractional anisotropy (FA) and mean diffusivity (MD) of MCP; anteroposterior diameter of pons; cerebellar FA and volume; pons and mean putamen volume; mean FA substantia nigra compacta-rostral) showed statistically significant (P < 0.05) differences between MSA and PD with mean MCP width, anteroposterior diameter of pons and mean FA MCP chosen for the decision tree. Threshold values were 14.6 mm, 21.8 mm and 0.55, respectively. Overall performance of the decision tree was 92 % sensitivity, 96 % specificity, 92 % PPV and 96 % NPV. Twelve out of 13 MSA patients were accurately classified.
CONCLUSION: Formation of the decision tree using these parameters was both descriptive and predictive in differentiating between MSA and PD.
KEY POINTS: • Parkinson's disease and multiple system atrophy can be distinguished on MR imaging. • Combined conventional MRI and diffusion tensor imaging improves the accuracy of diagnosis. • A decision tree is descriptive and predictive in differentiating between clinical entities. • A decision tree can reliably differentiate Parkinson's disease from multiple system atrophy.
METHODS: A phantom study was performed to investigate the correlation of (1)H MRS-visible lipids with the signal loss ratio (SLR) obtained using IOP imaging. A cross-sectional study approved by the institutional review board was carried out in 22 patients with different glioma grades. The patients underwent scanning using IOP imaging and single-voxel spectroscopy (SVS) using 3T MRI. The brain spectra acquisitions from solid and cystic components were obtained and correlated with the SLR for different grades.
RESULTS: The phantom study showed a positive linear correlation between lipid quantification at 0.9 parts per million (ppm) and 1.3 ppm with SLR (r = 0.79-0.99, p
METHODS: 1H-MRS utilising the Single-Voxel Spectroscopy (SVS) technique was performed using a 3.0Tesla MRI on 45 optic radiations (15 from healthy subjects, 15 from mild glaucoma patients, and 15 from severe glaucoma patients). A standardised Volume of Interest (VOI) of 20 × 20 × 20 mm was placed in the region of optic radiation. Mild and severe glaucoma patients were categorised based on the Hodapp-Parrish-Anderson (HPA) classification. Mean and multiple group comparisons for metabolite concentration and metabolite concentration ratio between glaucoma grades and healthy subjects were obtained using one-way ANOVA.
RESULTS: The metabolite concentration and metabolite concentration ratio between the optic radiations of glaucoma patients and healthy subjects did not demonstrate any significant difference (p > 0.05).
CONCLUSION: Our findings show no significant alteration of metabolite concentration associated with neurodegeneration that could be measured by single-voxel 1H-MRS in optic radiation among glaucoma patients.
KEY POINTS: • Glaucoma disease has a neurodegenerative component. • Metabolite changes have been observed in the neurodegenerative process in the brain. • Using SVS, no metabolite changes in optic radiation were attributed to glaucoma.
RESULTS: VF position asymmetry (VFPa and VFRa) was greater (p=0.012; p=0.001) and overall mobility (VFAP) was lower (p=0.008) in UVFP patients compared with healthy participants. ICC of repeatability of all metrics was good, ranged from 0.82 to 0.95 except for the inter-session VFPa (0.44).
CONCLUSION: Cine-MRI is feasible for assessing VF abduction and adduction. Derived quantitative metrics have good repeatability.
KEY POINTS: • Cine-MRI is used to assess vocal folds (VFs) mobility: abduction and adduction. • New quantitative metrics are derived from VF position and abduction potential. • Cine-MRI able to depict the difference between normal and abnormal VF mobility. • Cine-MRI derived quantitative metrics have good repeatability.
METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.
RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.
CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.
KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.
METHODS: This study included 344 patients from the Korean Obstructive Lung Disease (KOLD) cohort. External validation was performed on a cohort of 112 patients. In total, 525 chest CT-based radiomics features were semi-automatically extracted. The five most useful features for survival prediction were selected by least absolute shrinkage and selection operation (LASSO) Cox regression analysis and used to generate a RS. The ability of the RS for classifying COPD patients into high or low mortality risk groups was evaluated with the Kaplan-Meier survival analysis and Cox proportional hazards regression analysis.
RESULTS: The five features remaining after the LASSO analysis were %LAA-950, AWT_Pi10_6th, AWT_Pi10_heterogeneity, %WA_heterogeneity, and VA18mm. The RS demonstrated a C-index of 0.774 in the discovery group and 0.805 in the validation group. Patients with a RS greater than 1.053 were classified into the high-risk group and demonstrated worse overall survival than those in the low-risk group in both the discovery (log-rank test, < 0.001; hazard ratio [HR], 5.265) and validation groups (log-rank test, < 0.001; HR, 5.223). For both groups, RS was significantly associated with overall survival after adjustments for patient age and body mass index.
CONCLUSIONS: A radiomics approach for survival prediction and risk stratification in COPD patients is feasible, and the constructed radiomics model demonstrated acceptable performance. The RS derived from chest CT data of COPD patients was able to effectively identify those at increased risk of mortality.
KEY POINTS: • A total of 525 chest CT-based radiomics features were extracted and the five radiomics features of %LAA-950, AWT_Pi10_6th, AWT_Pi10_heterogeneity, %WA_heterogeneity, and VA18mm were selected to generate a radiomics model. • A radiomics model for predicting survival of COPD patients demonstrated reliable performance with a C-index of 0.774 in the discovery group and 0.805 in the validation group. • Radiomics approach was able to effectively identify COPD patients with an increased risk of mortality, and patients assigned to the high-risk group demonstrated worse overall survival in both the discovery and validation groups.
METHODS: Overall, 612 patients (306 COVID-19 and 306 non-COVID-19 pneumonia) were recruited. Twenty radiological features were extracted from CT images to evaluate the pattern, location, and distribution of lesions of patients in both groups. All significant CT features were fed in five classifiers namely decision tree, K-nearest neighbor, naïve Bayes, support vector machine, and ensemble to evaluate the best performing CAD system in classifying COVID-19 and non-COVID-19 cases.
RESULTS: Location and distribution pattern of involvement, number of the lesion, ground-glass opacity (GGO) and crazy-paving, consolidation, reticular, bronchial wall thickening, nodule, air bronchogram, cavity, pleural effusion, pleural thickening, and lymphadenopathy are the significant features to classify COVID-19 from non-COVID-19 groups. Our proposed CAD system obtained the sensitivity, specificity, and accuracy of 0.965, 93.54%, 90.32%, and 91.94%, respectively, using ensemble (COVIDiag) classifier.
CONCLUSIONS: This study proposed a COVIDiag model obtained promising results using CT radiological routine features. It can be considered an adjunct tool by the radiologists during the current COVID-19 pandemic to make an accurate diagnosis.
KEY POINTS: • Location and distribution of involvement, number of lesions, GGO and crazy-paving, consolidation, reticular, bronchial wall thickening, nodule, air bronchogram, cavity, pleural effusion, pleural thickening, and lymphadenopathy are the significant features between COVID-19 from non-COVID-19 groups. • The proposed CAD system, COVIDiag, could diagnose COVID-19 pneumonia cases with an AUC of 0.965 (sensitivity = 93.54%; specificity = 90.32%; and accuracy = 91.94%). • The AUC, sensitivity, specificity, and accuracy obtained by radiologist diagnosis are 0.879, 87.10%, 88.71%, and 87.90%, respectively.
MATERIALS AND METHODS: Seven hundred fifty-four radiomics-based features were extracted from 1732 scans derived from the TICH-2 multicentre clinical trial. Features were harmonised and a correlation-based feature selection was applied. Different elastic-net parameterisations were tested to assess the predictive performance of the selected radiomics-based features using grid optimisation. For comparison, the same procedure was run using radiological signs and clinical factors separately. Models trained with radiomics-based features combined with radiological signs or clinical factors were tested. Predictive performance was evaluated using the area under the receiver operating characteristic curve (AUC) score.
RESULTS: The optimal radiomics-based model showed an AUC of 0.693 for haematoma expansion and an AUC of 0.783 for poor functional outcome. Models with radiological signs alone yielded substantial reductions in sensitivity. Combining radiomics-based features and radiological signs did not provide any improvement over radiomics-based features alone. Models with clinical factors had similar performance compared to using radiomics-based features, albeit with low sensitivity for haematoma expansion. Performance of radiomics-based features was boosted by incorporating clinical factors, with time from onset to scan and age being the most important contributors for haematoma expansion and poor functional outcome prediction, respectively.
CONCLUSION: Radiomics-based features perform better than radiological signs and similarly to clinical factors on the prediction of haematoma expansion and poor functional outcome. Moreover, combining radiomics-based features with clinical factors improves their performance.
KEY POINTS: • Linear models based on CT radiomics-based features perform better than radiological signs on the prediction of haematoma expansion and poor functional outcome in the context of intracerebral haemorrhage. • Linear models based on CT radiomics-based features perform similarly to clinical factors known to be good predictors. However, combining these clinical factors with radiomics-based features increases their predictive performance.
MATERIALS AND METHODS: All patients who had 3D-ABUS between January 2014 and January 2022 for screening were included in this retrospective study. The images were reported by 1 of 6 breast radiologists based on the Breast Imaging Reporting and Data Systems (BI-RADS). The 3D-ABUS was reviewed together with the digital breast tomosynthesis (DBT). Recall rate, biopsy rate, positive predictive value (PPV) and cancer detection yield were calculated.
RESULTS: In total, 3616 studies were performed in 1555 women (breast density C/D 95.5% (n = 3455/3616), breast density A/B 4.0% (n = 144/3616), density unknown (0.5% (n = 17/3616)). A total of 259 lesions were detected on 3D-ABUS (87.6% (n = 227/259) masses and 12.4% (n = 32/259) architectural distortions). The recall rate was 5.2% (n = 188/3616) (CI 4.5-6.0%) with only 36.7% (n = 69/188) cases recalled to another date. Moreover, recall declined over time. There were 3.4% (n = 123/3616) biopsies performed, with 52.8% (n = 65/123) biopsies due to an abnormality detected in 3D-ABUS alone. Ten of 65 lesions were malignant, resulting in a positive predictive value (PPV) of 15.4% (n = 10/65) (CI 7.6-26.5%)). The cancer detection yield of 3D-ABUS is 2.77 per 1000 screening tests (CI 1.30-5.1).
CONCLUSION: The cancer detection yield of 3D-ABUS in a real clinical screening setting is comparable to the results reported in previous prospective studies, with lower recall and biopsy rates. 3D-ABUS also may be an alternative for screening when mammography is not possible or declined.
CLINICAL RELEVANCE STATEMENT: 3D automated breast ultrasound screening performance in a clinical setting is comparable to previous prospective studies, with better recall and biopsy rates.
KEY POINTS: • 3D automated breast ultrasound is a reliable and reproducible tool that provides a three-dimensional representation of the breast and allows image visualisation in axial, coronal and sagittal. • The diagnostic performance of 3D automated breast ultrasound in a real clinical setting is comparable to its performance in previously published prospective studies, with improved recall and biopsy rates. • 3D automated breast ultrasound is a useful adjunct to mammography in dense breasts and may be an alternative for screening when mammography is not possible or declined.