To determine if a volume-adjusted increase in the number of biopsy cores could detect more prostate cancers than the standard sextant biopsy alone, without increasing morbidity, and to determine its applicability in Malaysian patients, as a standard sextant biopsy misses 20-25% of prostate malignancies.
We report a hepatocellular carcinoma seeding following needle biopsy in a 57-year-old man who first presented with a focal hepatic lesion at another hospital. The patient had been a hepatitis B carrier for 20 years. Initial surveillance ultrasonography showed a lesion in segment IV, in the background of non-cirrhotic liver and normal serum alpha-foetoprotein level (8 ng/ml). A percutaneous needle biopsy was done and histopathology confirmed well-differentiated hepatocellular carcinoma. The patient had refused surgery and preferred to try traditional medicine. He presented to us four months after the initial biopsy with epigastric swelling. This was found to be due to a tumour seeding along the previous biopsy tract. He was given radiofrequency ablation (RFA) of tumour along the needle tract, in addition to the primary tumour. We conclude that the need for percutaneous needle biopsy should be critically evaluated in patients presenting with focal hepatic lesions and the role of RFA in treating tumour seeding needs further evaluation.
Percutaneous image-guided needle biopsy is typically performed in highly vascular organs or in tumours with rich macroscopic and microscopic blood supply. The main risks related to this procedure are haemorrhage and implantation of tumour cells in the needle tract after the biopsy needle is withdrawn. From numerous conducted studies, it was found that heating the needle tract using alternating current in radiofrequency (RF) range has a potential to minimize these effects. However, this solution requires the use of specially designed needles, which would make the procedure relatively expensive and complicated. Thus, we propose a simple solution by using readily available coaxial core biopsy needles connected to a radiofrequency ablation (RFA) generator. In order to do so, we have designed and developed an adapter to interface between these two devices. For evaluation purpose, we used a bovine liver as a sample tissue. The experimental procedure was done to study the effect of different parameter settings on the size of coagulation necrosis caused by the RF current heating on the subject. The delivery of the RF energy was varied by changing the values for delivered power, power delivery duration, and insertion depth. The results showed that the size of the coagulation necrosis is affected by all of the parameters tested. In general, the size of the region is enlarged with higher delivery of RF power, longer duration of power delivery, and shallower needle insertion and become relatively constant after a certain value. We also found that the solution proposed provides a low cost and practical way to minimizes unwanted post-biopsy effects.
Percutaneous biopsy in breast cancer has been associated with an increased risk of malignant cell seeding. However, the importance of these observations remains obscure due to lack of corroborating evidence from clinical studies. We determined whether method of biopsy is associated with breast cancer survival. This hospital registry-based cohort study included 3416 non-metastatic breast cancer patients diagnosed from 1993 to 2011 in a tertiary setting. Factors associated with biopsy methods were assessed. Multivariable Cox regression analysis was used to determine the independent prognostic impact of method of biopsy. Overall, 990 patients were diagnosed by core needle biopsy (CNB), 1364 by fine needle aspiration cytology (FNAC), and 1062 by excision biopsy. Excision biopsy was significantly associated with more favorable tumor characteristics. Radiotherapy modified the prognostic impact of biopsy method (Pinteraction