Displaying all 5 publications

Abstract:
Sort:
  1. Chan SC
    Med J Malaysia, 1997 Sep;52(3):244-50.
    PMID: 10968093
    Adequacy of active resuscitation in collapsed inpatients aged 12 and above (excluding those with terminal illness) were studied in 6 Malaysian district hospitals for 3 months starting 1/1/93. Results showed 59.5% (25 out of 42 inpatients) were inadequately resuscitated measured by: failure of nurses to initiate resuscitation (24%), duration of resuscitation less than 30 minutes (42%) and incompletely equipped emergency trolleys (44%). Questionnaires revealed lack of knowledge and training in cardiopulmonary resuscitation in medical staff. Regular cardiopulmonary resuscitation courses, regular spot checks on emergency trolleys and management protocols on active resuscitation are recommended. Each hospital should design its own criteria for adequacy.
    Matched MeSH terms: Cardiopulmonary Resuscitation/standards*
  2. Mohandas K
    Ann Acad Med Singap, 1992 Jan;21(1):47-50.
    PMID: 1590656
    Cardiopulmonary resuscitation training in Malaysia was started at the General Hospital Kuala Lumpur in 1986. Now the programme has been extended to all the General Hospitals in the country and is fully supported by the Ministry of Health. The American Heart Association curriculum for Basic Life Support is followed. From February 1986 till March 1991, the programme has trained 3982 in Basic Life Support and 548 in Advanced Cardiac Life Support. We are making efforts to translate some of the American manuals into the National language. A preliminary survey on early defibrillation indicates that majority of the physicians will allow defibrillation by non-physician.
    Matched MeSH terms: Cardiopulmonary Resuscitation/standards
  3. Chelladurai G, Noor Azhar AM, Mohd Isa R, Bustam A, Ahmad R, Munisamy M
    Med J Malaysia, 2020 09;75(5):514-518.
    PMID: 32918419
    INTRODUCTION: Cardiopulmonary Resuscitation (CPR) remains the primary mechanism of resuscitation for cardiac arrest victims. However, the quality of delivery of CPR varies widely in different settings, possibly affecting patient outcomes. This study is aimed to determine the efficacy of an audio-visual (AV) CPR feedback device in improving the quality of CPR delivered by healthcare providers.

    METHODS: This pre-post, single-arm, quasi-experimental study randomly sampled 140 healthcare providers working in the Emergency Department of Hospital Ampang, Malaysia. Parameters of CPR quality, namely chest compression rate and depth were compared among participants when they performed CPR with and without an AV CPR feedback device. The efficacy of the AV CPR feedback device was assessed using the Chi-square test and Generalised Estimating Equations (GEE) models.

    RESULTS: The use of an AV CPR feedback device increased the proportion of healthcare providers achieving recommended depth of chest compressions from 38.6% (95% Confidence Interval, 95%CI: 30.5, 47.2) to 85.0% (95%CI: 78.0, 90.5). A similar significant improvement from 39.3% (95%CI: 31.1, 47.9) to 86.4% (95%CI: 79.6, 91.6) in the recommended rate of chest compressions was also observed. Use of the AV CPR device significantly increased the likelihood of a CPR provider achieving recommended depth of chest compressions (Odds Ratio, OR=13.01; 95%CI: 7.12, 24.01) and rate of chest compressions (OR=13.00; 95%CI: 7.21, 23.44).

    CONCLUSION: The use of an AV CPR feedback device significantly improved the delivered rate and depth of chest compressions closer to American Heart Association (AHA) recommendations. Usage of such devices within real-life settings may help in improving the quality of CPR for patients receiving CPR.

    Matched MeSH terms: Cardiopulmonary Resuscitation/standards*
  4. Saiboon IM, Apoo FN, Jamal SM, Bakar AA, Yatim FM, Jaafar JM, et al.
    Medicine (Baltimore), 2019 Dec;98(49):e18201.
    PMID: 31804343 DOI: 10.1097/MD.0000000000018201
    BACKGROUND: Leadership and teamwork are important contributory factors in determining cardiac resuscitation performance and clinical outcome. We aimed to determine whether fixed positioning of the resuscitation team leader (RTL) relative to the patient influences leadership qualities during cardiac resuscitation using simulation.

    METHODS: A cross-sectional randomized intervention study over 12 months' duration was conducted in university hospital simulation lab. ACLS-certified medical doctors were assigned to run 2 standardized simulated resuscitation code as RTL from a head-end position (HEP) and leg-end position (LEP). They were evaluated on leadership qualities including situational attentiveness (SA), errors detection (ED), and decision making (DM) using a standardized validated resuscitation-code-checklist (RCC). Performance was assessed live by 2 independent raters and was simultaneously recorded. RTL self-perceived performance was compared to measured performance.

    RESULTS: Thirty-four participants completed the study. Mean marks for SA were 3.74 (SD ± 0.96) at HEP and 3.54 (SD ± 0.92) at LEP, P = .48. Mean marks for ED were 2.43 (SD ± 1.24) at HEP and 2.21 (SD ± 1.14) at LEP, P = .40. Mean marks for DM were 4.53 (SD ± 0.98) at HEP and 4.47 (SD ± 0.73) at LEP, P = .70. The mean total marks were 10.69 (SD ± 1.82) versus 10.22 (SD ± 1.93) at HEP and LEP respectively, P = .29 which shows no significance difference in all parameters. Twenty-four participants (71%) preferred LEP for the following reasons, better visualization (75% of participants); more room for movement (12.5% of participants); and better communication (12.5% of participants). RTL's perceived performance did not correlate with actual performance CONCLUSION:: The physical position either HEP or LEP appears to have no influence on performance of RTL in simulated cardiac resuscitation. RTL should be aware of the advantages and limitations of each position.

    Matched MeSH terms: Cardiopulmonary Resuscitation/standards*
  5. Kim TH, Lee K, Shin SD, Ro YS, Tanaka H, Yap S, et al.
    J Emerg Med, 2017 Nov;53(5):688-696.e1.
    PMID: 29128033 DOI: 10.1016/j.jemermed.2017.08.076
    BACKGROUND: Response time interval (RTI) and scene time interval (STI) are key time variables in the out-of-hospital cardiac arrest (OHCA) cases treated and transported via emergency medical services (EMS).

    OBJECTIVE: We evaluated distribution and interactive association of RTI and STI with survival outcomes of OHCA in four Asian metropolitan cities.

    METHODS: An OHCA cohort from Pan-Asian Resuscitation Outcome Study (PAROS) conducted between January 2009 and December 2011 was analyzed. Adult EMS-treated cardiac arrests with presumed cardiac origin were included. A multivariable logistic regression model with an interaction term was used to evaluate the effect of STI according to different RTI categories on survival outcomes. Risk-adjusted predicted rates of survival outcomes were calculated and compared with observed rate.

    RESULTS: A total of 16,974 OHCA cases were analyzed after serial exclusion. Median RTI was 6.0 min (interquartile range [IQR] 5.0-8.0 min) and median STI was 12.0 min (IQR 8.0-16.1). The prolonged STI in the longest RTI group was associated with a lower rate of survival to discharge or of survival 30 days after arrest (adjusted odds ratio [aOR] 0.59; 95% confidence interval [CI] 0.42-0.81), as well as a poorer neurologic outcome (aOR 0.63; 95% CI 0.41-0.97) without an increasing chance of prehospital return of spontaneous circulation (aOR 1.12; 95% CI 0.88-1.45).

    CONCLUSIONS: Prolonged STI in OHCA with a delayed response time had a negative association with survival outcomes in four Asian metropolitan cities using the scoop-and-run EMS model. Establishing an optimal STI based on the response time could be considered.

    Matched MeSH terms: Cardiopulmonary Resuscitation/standards
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links