Displaying all 9 publications

Abstract:
Sort:
  1. Ghosh HK
    Med J Malaya, 1970 Jun;24(4):300-1.
    PMID: 4248352
    Matched MeSH terms: Cholera/diagnosis*
  2. Eapen JS
    Med J Malaya, 1965 Mar;19(3):213-21.
    PMID: 4220473
    Matched MeSH terms: Cholera/diagnosis*
  3. Low KF, Karimah A, Yean CY
    Biosens Bioelectron, 2013 Sep 15;47:38-44.
    PMID: 23545172 DOI: 10.1016/j.bios.2013.03.004
    Vibrio cholerae is a human pathogen that causes mild to severe diarrheal illnesses and has major public health significance. Herein, we present a thermostabilized electrochemical genosensing assay combining the use of magnetic beads as a biorecognition platform and gold nanoparticles as a hybridization tag for the detection and quantification of V. cholerae lolB gene single-stranded asymmetric PCR amplicons as an alternative to the time-consuming classical isolation method. This thermostabilized, pre-mixed, pre-aliquoted and ready-to-use magnetogenosensing assay simplified the procedures and permitted the reaction to be conducted at room temperature. The asymmetric PCR amplicons were hybridized to a magnetic bead-functionalized capture probe and a fluorescein-labeled detection probe followed by tagging with gold nanoparticles. Electrochemical detection of the chemically dissolved gold nanoparticles was performed using the differential pulse anodic stripping voltammetry method. The real-time stability evaluation of thermostabilized assay was found to be stable for at least 180 days at room temperature (25-30°C). The analytical specificity of the assay was 100%, while its analytical sensitivity was linearly related to different concentrations of 200-mer synthetic target, purified genomic DNA, and bacterial culture with a limit of detection (LoD) of 3.9nM, 5pg/µl, and 10(3)CFU/ml, respectively. The clinical applicability of the assay was successfully validated using spiked stool samples with an average current signal-to-cut-off ratio of 10.8. Overall, the precision of the assay via relative standard deviation was <10%, demonstrating its reliability and accuracy.
    Matched MeSH terms: Cholera/diagnosis*
  4. Engku Nur Syafirah EAR, Nurul Najian AB, Foo PC, Mohd Ali MR, Mohamed M, Yean CY
    Acta Trop, 2018 Jun;182:223-231.
    PMID: 29545156 DOI: 10.1016/j.actatropica.2018.03.004
    Cholera, caused by Vibrio cholerae is a foodborne disease that frequently reported in food and water related outbreak. Rapid diagnosis of cholera infection is important to avoid potential spread of disease. Among available diagnostic platforms, loop-mediated isothermal amplification (LAMP) is regarded as a potential diagnostic tool due to its rapidity, high sensitivity and specificity and independent of sophisticated thermalcycler. However, the current LAMP often requires multiple pipetting steps, hence is susceptible to cross contamination. Besides, the strict requirement of cold-chain during transportation and storage make its application in low resource settings to be inconvenient. To overcome these problems, the present study is aimed to develop an ambient-temperature-stable and ready-to-use LAMP assay for the detection of toxigenic Vibrio cholerae in low resource settings. A set of specific LAMP primers were designed and tested against 155 V. cholerae and non-V. cholerae strains. Analytical specifity showed that the developed LAMP assay detected 100% of pathogenic V. cholerae and did not amplified other tested bacterial strains. Upon testing against stool samples spiked with toxigenic V. cholerae outbreak isolates, the LAMP assay detected all of the spiked samples (n = 76/76, 100%), in contrast to the conventional PCR which amplified 77.6% (n = 59/76) of the tested specimens. In term of sensitivity, the LAMP assay was 100-fold more sensitive as compared to the conventional PCR method, with LOD of 10 fg per μL and 10 CFU per mL. Following lyophilisation with addition of lyoprotectants, the dry-reagent LAMP mix has an estimated shelf-life of 90.75 days at room temperature.
    Matched MeSH terms: Cholera/diagnosis*
  5. Yu CY, Ang GY, Chua AL, Tan EH, Lee SY, Falero-Diaz G, et al.
    J Microbiol Methods, 2011 Sep;86(3):277-82.
    PMID: 21571011 DOI: 10.1016/j.mimet.2011.04.020
    Cholera is a communicable disease caused by consumption of contaminated food and water. This potentially fatal intestinal infection is characterised by profuse secretion of rice watery stool that can rapidly lead to severe dehydration and shock, thus requiring treatment to be given immediately. Epidemic and pandemic cholera are exclusively associated with Vibrio cholerae serogroups O1 and O139. In light of the need for rapid diagnosis of cholera and to prevent spread of outbreaks, we have developed and evaluated a direct one-step lateral flow biosensor for the simultaneous detection of both V. cholerae O1 and O139 serogroups using alkaline peptone water culture. Serogroup specific monoclonal antibodies raised against lipopolysaccharides (LPS) were used to functionalize the colloidal gold nanoparticles for dual detection in the biosensor. The assay is based on immunochromatographic principle where antigen-antibody reaction would result in the accumulation of gold nanoparticles and thus, the appearance of a red line on the strip. The dry-reagent dipstick format of the biosensor ensure user-friendly application, rapid result that can be read with the naked eyes and cold-chain free storage that is well-suited to be performed at resource-limited settings.
    Matched MeSH terms: Cholera/diagnosis*
  6. Liew PS, Lertanantawong B, Lee SY, Manickam R, Lee YH, Surareungchai W
    Talanta, 2015 Jul 1;139:167-73.
    PMID: 25882423 DOI: 10.1016/j.talanta.2015.02.054
    Vibrio cholerae is a Gram-negative bacterium that causes cholera, a diarrheal disease. Cholera is widespread in poor, under-developed or disaster-hit countries that have poor water sanitation. Hence, a rapid detection method for V. cholerae in the field under these resource-limited settings is required. In this paper, we describe the development of an electrochemical genosensor assay using lyophilized gold nanoparticles/latex microsphere (AuNPs-PSA) reporter label. The reporter label mixture was prepared by lyophilization of AuNPs-PSA-avidin conjugate with different types of stabilizers. The best stabilizer was 5% sorbitol, which was able to preserve the dried conjugate for up to 30 days. Three methods of DNA hybridization were compared and the one-step sandwich hybridization method was chosen as it was fastest and highly specific. The performance of the assay using the lyophilized reagents was comparable to the wet form for detection of 1aM to 1fM of linear target DNA. The assay was highly specific for V. cholerae, with a detection limit of 1fM of PCR products. The ability of the sensor is to detect LAMP products as low as 50ngµl(-1). The novel lyophilized AuNPs-PSA-avidin reporter label with electrochemical genosensor detection could facilitate the rapid on-site detection of V. cholerae.
    Matched MeSH terms: Cholera/diagnosis*
  7. Rohani MY, Hasnidah D, Ong KH
    Malays J Pathol, 1998 Jun;20(1):31-3.
    PMID: 10879261
    A chromatographic immunoassay cholera antigen detection kit, the Cholera Spot test, was evaluated. The test was found to be specific with a sensitivity of 10(6) cfu/ml for the direct detection of V. cholerae in simulated stool specimens and 10 cfu/ml in simulated cotton-tipped swab specimens after overnight incubation in alkaline peptone water. This enables early recognition of cholera cases and their contacts so that prevention and control measures can be promptly instituted.
    Matched MeSH terms: Cholera/diagnosis*
  8. Ang GY, Yu CY, Yean CY
    Biosens Bioelectron, 2012 Oct-Dec;38(1):151-6.
    PMID: 22705404 DOI: 10.1016/j.bios.2012.05.019
    In the field of diagnostics, molecular amplification targeting unique genetic signature sequences has been widely used for rapid identification of infectious agents, which significantly aids physicians in determining the choice of treatment as well as providing important epidemiological data for surveillance and disease control assessment. We report the development of a rapid nucleic acid lateral flow biosensor (NALFB) in a dry-reagent strip format for the sequence-specific detection of single-stranded polymerase chain reaction (PCR) amplicons at ambient temperature (22-25°C). The NALFB was developed in combination with a linear-after-the-exponential PCR assay and the applicability of this biosensor was demonstrated through detection of the cholera toxin gene from diarrheal-causing toxigenic Vibrio cholerae. Amplification using the advanced asymmetric PCR boosts the production of fluorescein-labeled single-stranded amplicons, allowing capture probes immobilized on the NALFB to hybridize specifically with complementary targets in situ on the strip. Subsequent visual formation of red lines is achieved through the binding of conjugated gold nanoparticles to the fluorescein label of the captured amplicons. The visual detection limit observed with synthetic target DNA was 0.3 ng and 1 pg with pure genomic DNA. Evaluation of the NALFB with 164 strains of V. cholerae and non-V. cholerae bacteria recorded 100% for both sensitivity and specificity. The whole procedure of the low-cost NALFB, which is performed at ambient temperature, eliminates the need for preheated buffers or additional equipment, greatly simplifying the protocol for sequence-specific PCR amplicon analysis.
    Matched MeSH terms: Cholera/diagnosis
  9. Low KF, Zain ZM, Yean CY
    Biosens Bioelectron, 2017 Jan 15;87:256-263.
    PMID: 27567251 DOI: 10.1016/j.bios.2016.08.064
    A novel enzyme/nanoparticle-based DNA biosensing platform with dual colorimetric/electrochemical approach has been developed for the sequence-specific detection of the bacterium Vibrio cholerae, the causative agent of acute diarrheal disease in cholera. This assay platform exploits the use of shelf-stable and ready-to-use (shelf-ready) reagents to greatly simplify the bioanalysis procedures, allowing the assay platform to be more amenable to point-of-care applications. To assure maximum diagnosis reliability, an internal control (IC) capable of providing instant validation of results was incorporated into the assay. The microbial target, single-stranded DNA amplified with asymmetric PCR, was quantitatively detected via electrochemical stripping analysis of gold nanoparticle-loaded latex microspheres as a signal-amplified hybridization tag, while the incorporated IC was analyzed using a simplified horseradish peroxidase enzyme-based colorimetric scheme by simple visual observation of enzymatic color development. The platform showed excellent diagnostic sensitivity and specificity (100%) when challenged with 145 clinical isolate-spiked fecal specimens. The limits of detection were 0.5ng/ml of genomic DNA and 10 colony-forming units (CFU)/ml of bacterial cells with dynamic ranges of 0-100ng/ml (R(2)=0.992) and log10 (1-10(4) CFU/ml) (R(2)=0.9918), respectively. An accelerated stability test revealed that the assay reagents were stable at temperatures of 4-37°C, with an estimated ambient shelf life of 200 days. The versatility of the biosensing platform makes it easily adaptable for quantitative detection of other microbial pathogens.
    Matched MeSH terms: Cholera/diagnosis*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links