Displaying all 3 publications

Abstract:
Sort:
  1. Boo NY, Mohd-Amin I, Bilkis AA, Yong-Junina F
    Singapore Med J, 2006 Sep;47(9):763-8.
    PMID: 16924357
    Introduction: The aim of this study was to determine predictors of failed closure of patent ductus arteriosus (PDA) following a single course of indomethacin in symptomatic preterm infants.
    Methods: This prospective observational study was carried out on 60 preterm infants weighing less than 1,750 g with symptomatic PDA confirmed by echocardiography. At a median age of 7.0 days (interquartile range 4.0), they were given indomethacin of 0.1 mg/kg/day intravenously daily for six days. Closure of PDA was reassessed by echocardiography upon completion of therapy.
    Results: The PDA of 40 percent (n=24) of these infants remained patent. Forward logistic regression analysis showed that the only significant predictors of failed PDA closure in these infants were: PDA size (adjusted odds-ratio [OR] is 7.0; 95 percent confidence interval [CI] of OR is 2.0, 24.8; p-value is 0.002), birth weight (adjusted OR is 0.996; 95 percent CI of OR is 0.993, 1.000; p-value is 0.03) and platelet count (adjusted OR is 0.987; 95 percent CI is 0.975, 1.000; p-value is 0.045). Gestational age, maternal age and left atrium/aorta ratios were not significant predictors.
    Conclusion: Larger PDA, lower birth weight and lower platelet count were significant predictors of high failure in indomethacin therapy given late at one week of life.
    Matched MeSH terms: Ductus Arteriosus, Patent/ultrasonography
  2. Zanjani KS, Wong AR, Sadiq M, Weber HS, Cutler NG
    Congenit Heart Dis, 2010 Sep-Oct;5(5):439-43.
    PMID: 21087429 DOI: 10.1111/j.1747-0803.2010.00448.x
    Objectives: There is little evidence in the medical literature about safety of PDA device closure and its effects on aortic root diameter in Marfan patients. We reported on nine Marfan patients whose ducts were occluded by coil or Amplatzer Duct Occluder.
    Patients and interventions: Two patients had aneurismal type E ducts which were closed by a single coil, respectively. The others had conical ducts for which even Amplatzer occluder, stiff, or double coils were used.
    Results: No untoward consequence was found during a median follow up period of 18.5 months (range 3 months to 6.33 years). Two patients had small residual shunts. The observed change in the mean ratio of aortic root diameter to its estimated value was statistically insignificant in seven patients who had complete data on their aortic root diameter before PDA closure and during the follow up.
    Conclusions: We concluded that PDA device closure in Marfan patients is safe. Risk of residual shunt is higher even after closure of small ducts.
    Matched MeSH terms: Ductus Arteriosus, Patent/ultrasonography
  3. Alwi M, Choo KK, Radzi NA, Samion H, Pau KK, Hew CC
    J. Thorac. Cardiovasc. Surg., 2011 Jun;141(6):1355-61.
    PMID: 21227471 DOI: 10.1016/j.jtcvs.2010.08.085
    Objectives: Our objective was to determine the feasibility and early to medium-term outcome of stenting the patent ductus arteriosus at the time of radiofrequency valvotomy in the subgroup of patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle.
    Background: Stenting of the patent ductus arteriosus and radiofrequency valvotomy have been proposed as the initial intervention for patients with intermediate right ventricle inasmuch as the sustainability for biventricular circulation or 1½-ventricle repair is unclear in the early period.
    Methods: Between January 2001 and April 2009, of 143 patients with pulmonary atresia and intact ventricular septum, 37 who had bipartite right ventricle underwent radiofrequency valvotomy and stenting of the patent ductus arteriosus as the initial procedure. The mean tricuspid valve z-score was -3.8 ± 2.2 and the mean tricuspid valve/mitral valve ratio was 0.62 ± 0.16.
    Results: Median age was 10 days (3-65 days) and median weight 3.1 kg (2.4-4.9 kg). There was no procedural mortality. Acute stent thrombosis developed in 1 patient and necessitated emergency systemic-pulmonary shunt. There were 2 early in-hospital deaths owing to low cardiac output syndrome. One late death occurred owing to right ventricular failure after the operation. Survival after the initial procedure was 94% at 6 months and 91% at 5 years. At a median follow-up of 4 years (6 months to 8 years), 17 (48%) attained biventricular circulation with or without other interventions and 9 (26%) achieved 1½-ventricle repair. The freedom from reintervention was 80%, 68%, 58%, and 40% at 1, 2, 3, and 4 years, respectively.
    Conclusions: Concomitant stenting of the patent ductus arteriosus at the time of radiofrequency valvotomy in patients with pulmonary atresia with intact ventricular septum and intermediate right ventricle is feasible and safe with encouraging medium-term outcome.
    Matched MeSH terms: Ductus Arteriosus, Patent/ultrasonography