Displaying all 4 publications

Abstract:
Sort:
  1. Jung HJ, Kwon WK, Lee SJ, Mohamed N, Shin BM, Lee J, et al.
    BMC Anesthesiol, 2016 10 04;16(1):83.
    PMID: 27716083
    BACKGROUND: This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

    CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

    CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.

    Matched MeSH terms: Echocardiography, Three-Dimensional/methods
  2. Tamin SS, Dillon J, Aizan K, Kadiman S, Latiff HA
    Echocardiography, 2012 Feb;29(2):E34-8.
    PMID: 22044509 DOI: 10.1111/j.1540-8175.2011.01543.x
    This case report describes a 20-year-old woman with Turner's syndrome who presented with reduced effort tolerance limited by dyspnea. She had previously been on pediatric cardiology follow-up for congenital subvalvular aortic stenosis first diagnosed at age 7. Unfortunately she defaulted after two visits before any intervention could be done. Transthoracic echocardiography demonstrated severe aortic incompetence (AI) with a membrane-like structure in the left ventricular outflow tract (LVOT). The mean pressure gradient across the LVOT on continuous wave Doppler was 41 mmHg. The membranous interventricular septum appeared aneurysmal and it was observed that the "subaortic membrane" had a connection to the anterolateral papillary muscle via a strand of chordal tissue. Further images were captured using two-dimensional and three-dimensional transthoracic and transesophageal echocardiography (iE33, Philips Medical Systems, Andover, MA, USA). After a review of the literature it was concluded that this appeared to be an accessory mitral valve (AMV) leaflet causing LVOT obstruction associated with AI. AMV tissue is a rare congenital malformation causing LVOT obstruction. Because it is so unusual, it may not be immediately recognizable even in a high volume echocardiography laboratory. The clue which helped with the diagnosis was the strand of chordal tissue which connected the mass to the papillary muscle. This anomaly is often associated with LVOT obstruction.
    Matched MeSH terms: Echocardiography, Three-Dimensional/methods
  3. Qureshi AU, Latiff HA, Sivalingam S
    Cardiol Young, 2014 Aug;24(4):756-9.
    PMID: 24016801 DOI: 10.1017/S1047951113001200
    Incomplete involution of valve of systemic venous sinus can present across a spectrum of anatomical lesions ranging from eustachian valve to division of right atrium (cor triatriatum dexter) with overlapping features. We present the case of a neonate presenting with cyanosis, having persistent valve of systemic venous sinus with anatomical details of the redundant tissue in right atrium suggesting an intermediate form between Chiari network and division of right atrium.
    Matched MeSH terms: Echocardiography, Three-Dimensional
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links