Displaying all 6 publications

Abstract:
Sort:
  1. Al-Kadi MI, Reaz MB, Ali MA
    Sensors (Basel), 2013;13(5):6605-35.
    PMID: 23686141 DOI: 10.3390/s130506605
    Biosignal analysis is one of the most important topics that researchers have tried to develop during the last century to understand numerous human diseases. Electroencephalograms (EEGs) are one of the techniques which provides an electrical representation of biosignals that reflect changes in the activity of the human brain. Monitoring the levels of anesthesia is a very important subject, which has been proposed to avoid both patient awareness caused by inadequate dosage of anesthetic drugs and excessive use of anesthesia during surgery. This article reviews the bases of these techniques and their development within the last decades and provides a synopsis of the relevant methodologies and algorithms that are used to analyze EEG signals. In addition, it aims to present some of the physiological background of the EEG signal, developments in EEG signal processing, and the effective methods used to remove various types of noise. This review will hopefully increase efforts to develop methods that use EEG signals for determining and classifying the depth of anesthesia with a high data rate to produce a flexible and reliable detection device.
    Matched MeSH terms: Electroencephalography/instrumentation*
  2. Fiedler P, Pedrosa P, Griebel S, Fonseca C, Vaz F, Supriyanto E, et al.
    Brain Topogr, 2015 Sep;28(5):647-656.
    PMID: 25998854 DOI: 10.1007/s10548-015-0435-5
    Current usage of electroencephalography (EEG) is limited to laboratory environments. Self-application of a multichannel wet EEG caps is practically impossible, since the application of state-of-the-art wet EEG sensors requires trained laboratory staff. We propose a novel EEG cap system with multipin dry electrodes overcoming this problem. We describe the design of a novel 24-pin dry electrode made from polyurethane and coated with Ag/AgCl. A textile cap system holds 97 of these dry electrodes. An EEG study with 20 volunteers compares the 97-channel dry EEG cap with a conventional 128-channel wet EEG cap for resting state EEG, alpha activity, eye blink artifacts and checkerboard pattern reversal visual evoked potentials. All volunteers report a good cap fit and good wearing comfort. Average impedances are below 150 kΩ for 92 out of 97 dry electrodes, enabling recording with standard EEG amplifiers. No significant differences are observed between wet and dry power spectral densities for all EEG bands. No significant differences are observed between the wet and dry global field power time courses of visual evoked potentials. The 2D interpolated topographic maps show significant differences of 3.52 and 0.44% of the map areas for the N75 and N145 VEP components, respectively. For the P100 component, no significant differences are observed. Dry multipin electrodes integrated in a textile EEG cap overcome the principle limitations of wet electrodes, allow rapid application of EEG multichannel caps by non-trained persons, and thus enable new fields of application for multichannel EEG acquisition.
    Matched MeSH terms: Electroencephalography/instrumentation*
  3. Al-Kadi MI, Reaz MB, Ali MA, Liu CY
    Sensors (Basel), 2014;14(7):13046-69.
    PMID: 25051031 DOI: 10.3390/s140713046
    This paper presents a comparison between the electroencephalogram (EEG) channels during scoliosis correction surgeries. Surgeons use many hand tools and electronic devices that directly affect the EEG channels. These noises do not affect the EEG channels uniformly. This research provides a complete system to find the least affected channel by the noise. The presented system consists of five stages: filtering, wavelet decomposing (Level 4), processing the signal bands using four different criteria (mean, energy, entropy and standard deviation), finding the useful channel according to the criteria's value and, finally, generating a combinational signal from Channels 1 and 2. Experimentally, two channels of EEG data were recorded from six patients who underwent scoliosis correction surgeries in the Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM) (the Medical center of National University of Malaysia). The combinational signal was tested by power spectral density, cross-correlation function and wavelet coherence. The experimental results show that the system-outputted EEG signals are neatly switched without any substantial changes in the consistency of EEG components. This paper provides an efficient procedure for analyzing EEG signals in order to avoid averaging the channels that lead to redistribution of the noise on both channels, reducing the dimensionality of the EEG features and preparing the best EEG stream for the classification and monitoring stage.
    Matched MeSH terms: Electroencephalography/instrumentation*
  4. Aziz F, Arof H, Mokhtar N, Mubin M
    J Neural Eng, 2014 Oct;11(5):056018.
    PMID: 25188730 DOI: 10.1088/1741-2560/11/5/056018
    This paper presents a wheelchair navigation system based on a hidden Markov model (HMM), which we developed to assist those with restricted mobility. The semi-autonomous system is equipped with obstacle/collision avoidance sensors and it takes the electrooculography (EOG) signal traces from the user as commands to maneuver the wheelchair. The EOG traces originate from eyeball and eyelid movements and they are embedded in EEG signals collected from the scalp of the user at three different locations. Features extracted from the EOG traces are used to determine whether the eyes are open or closed, and whether the eyes are gazing to the right, center, or left. These features are utilized as inputs to a few support vector machine (SVM) classifiers, whose outputs are regarded as observations to an HMM. The HMM determines the state of the system and generates commands for navigating the wheelchair accordingly. The use of simple features and the implementation of a sliding window that captures important signatures in the EOG traces result in a fast execution time and high classification rates. The wheelchair is equipped with a proximity sensor and it can move forward and backward in three directions. The asynchronous system achieved an average classification rate of 98% when tested with online data while its average execution time was less than 1 s. It was also tested in a navigation experiment where all of the participants managed to complete the tasks successfully without collisions.
    Matched MeSH terms: Electroencephalography/instrumentation*
  5. Doufesh H, Faisal T, Lim KS, Ibrahim F
    Appl Psychophysiol Biofeedback, 2012 Mar;37(1):11-8.
    PMID: 21965118 DOI: 10.1007/s10484-011-9170-1
    This study investigated the proposition of relaxation offered by performing the Muslim prayers by measuring the alpha brain activity in the frontal (F3-F4), central (C3-C4), parietal (P3-P4), and occipital (O1-O2) electrode placements using the International 10-20 System. Nine Muslim subjects were asked to perform the four required cycles of movements of Dhuha prayer, and the EEG were subsequently recorded with open eyes under three conditions, namely, resting, performing four cycles of prayer while reciting the specific verses and supplications, and performing four cycles of acted salat condition (prayer movements without any recitations). Analysis of variance (ANOVA) tests revealed that there were no significant difference in the mean alpha relative power (RP(α)) between the alpha amplitude in the Dhuha prayer and the acted conditions in all eight electrode positions. However, the mean RP(α) showed higher alpha amplitude during the prostration position of the Dhuha prayer and acted condition at the parietal and occipital regions in comparison to the resting condition. Findings were similar to other studies documenting increased alpha amplitude in parietal and occipital regions during meditation and mental concentration. The incidence of increased alpha amplitude suggested parasympathetic activation, thus indicating a state of relaxation. Subsequent studies are needed to delineate the role of mental concentration, and eye focus, on alpha wave amplitude while performing worshipping acts.
    Matched MeSH terms: Electroencephalography/instrumentation
  6. Ibrahim IA, Ting HN, Moghavvemi M
    J Int Adv Otol, 2019 Apr;15(1):87-93.
    PMID: 30924771 DOI: 10.5152/iao.2019.4553
    OBJECTIVES: This study uses a new approach for classifying the human ethnicity according to the auditory brain responses (electroencephalography [EEG] signals) with a high level of accuracy. Moreover, the study presents three different algorithms used to classify the human ethnicity using auditory brain responses. The algorithms were tested on Malays and Chinese as a case study.

    MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy.

    RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%.

    CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.

    Matched MeSH terms: Electroencephalography/instrumentation*