Displaying all 12 publications

Abstract:
Sort:
  1. Ayob KA, Merican AM, Sulaiman SH, Hariz Ramli AR
    Jt Dis Relat Surg, 2021;32(1):239-244.
    PMID: 33463444 DOI: 10.5606/ehc.2021.77862
    Injuries to the pelvic vasculature during total hip arthroplasties are rare but have serious consequence. They demand urgent and early identification so that appropriate treatment can be instituted. If the bleeding is severe, cardiovascular compromise occurs intraoperatively and this will alert the surgeon of this possibility during acetabular screw placement. Alternatively, a delay in diagnosis can occur because the bleeding and the injured vessel are in the pelvic cavity and not visualized during the surgery. In this article, we report two cases from our center occurring within a six-month interval that sustained a vascular injury during acetabular drilling for screw placement for cementless cup fixation. Each case had a different vessel injury and different lessons can be learned from these rare injuries. The first case had an injury of the inferior gluteal artery following a breach of the sciatic notch. The vessel was treated with percutaneous embolization. The second case demonstrated a venous injury, following a medial protrusio technique for congenital hip dysplasia and a short anterosuperior screw, transecting the external iliac vein. This was subsequently repaired using an endovascular technique. We conclude the reasons for these vessel injuries after analyzing advanced imaging, discuss measures to avoid vessel injury and detail the minimally invasive method for their treatment.
    Matched MeSH terms: Endovascular Procedures/methods*
  2. Wan Ab Naim WN, Ganesan PB, Sun Z, Lei J, Jansen S, Hashim SA, et al.
    Int J Numer Method Biomed Eng, 2018 05;34(5):e2961.
    PMID: 29331052 DOI: 10.1002/cnm.2961
    Endovascular stent graft repair has become a common treatment for complicated Stanford type B aortic dissection to restore true lumen flow and induce false lumen thrombosis. Using computational fluid dynamics, this study reports the differences in flow patterns and wall shear stress distribution in complicated Stanford type B aortic dissection patients after endovascular stent graft repair. Five patients were included in this study: 2 have more than 80% false lumen thrombosis (group 1), while 3 others had less than 80% false lumen thrombosis (group 2) within 1 year following endovascular repair. Group 1 patients had concentrated re-entry tears around the abdominal branches only, while group 2 patients had re-entry tears that spread along the dissection line. Blood flow inside the false lumen which affected thrombus formation increased with the number of re-entry tears and when only small amounts of blood that entered the false lumen exited through the branches. In those cases where dissection extended below the abdominal branches (group 2), patients with fewer re-entry tears and longer distance between the tears had low wall shear stress contributing to thrombosis. This work provides an insight into predicting the development of complete or incomplete false lumen thrombosis and has implications for patient selection for treatment.
    Matched MeSH terms: Endovascular Procedures/methods*
  3. Zainal IA, Fuad NFN, Yang LY, Ismail NAN, Yaacob NY, Zakaria R
    J Egypt Natl Canc Inst, 2024 May 13;36(1):15.
    PMID: 38736004 DOI: 10.1186/s43046-024-00216-4
    BACKGROUND: Giant sacrococcygeal teratomas (SCTs) are at risk of perinatal morbidity and mortality due to their high vascularity. Pre-operative embolization of the feeding arteries, prior to complete surgical resection, may assist in minimizing the intraoperative blood loss by occluding these feeding arteries.

    CASE PRESENTATION: We present a case of a highly vascular giant SCT in a neonate, which was successfully embolized through an endovascular approach prior to surgery. The femoral artery approach was chosen, with access established using a Micropuncture introducer as a sheath. Embolization was performed using a combination of microcoils, Gelfoam slurry, and polyvinyl alcohol particles. The patient developed femoral artery spasm post-procedure, which resolved with the application of a glyceryl trinitrate patch.

    CONCLUSIONS: Performing pre-operative endovascular embolization on a giant sacrococcygeal teratoma presents particular challenges, primarily due to the difficulty in assessing small vessels and the potential complications associated with this procedure. Nevertheless, this technique proves exceptionally valuable in helping the surgeon minimize blood loss during surgery, thereby reducing the risks of morbidity and mortality. Comprehensive planning for the embolization procedure is essential, encompassing the identification of potential vascular access points and alternatives, along with careful selection of the appropriate catheter.

    Matched MeSH terms: Endovascular Procedures/methods
  4. Tang IP, Chai CK, Kumar G, Prepageran N, Waran V
    Br J Neurosurg, 2014 Jun;28(3):390-2.
    PMID: 23875880 DOI: 10.3109/02688697.2013.817535
    Isolated intrasellar pituitary mucocele following transsphenoidal sinus surgery is extremely rare. The clinical features resemble a pituitary tumor, therefore careful radiological interpretation is crucial to reach the correct diagnosis. We report a case of intrasellar mucocele who had transsphenoidal sinus surgery performed 15 years prior.
    Matched MeSH terms: Endovascular Procedures/methods
  5. Hamad M, Rajan R, Kosai N, Sutton P, Das S, Harunarashid H
    Ethiop J Health Sci, 2016 Jan;26(1):85-8.
    PMID: 26949321
    BACKGROUND: Complication following fracture of a central venous catheter can be catastrophic to both the patient and the attending doctor. Catheter fracture has been attributed to several factors namely prolong mechanical force acting on the catheter, and forceful removal or insertion of the catheter.

    CASE DETAILS: In the present case, the fracture was suspected during the process of removal. The tip of the catheter was notably missing, and an emergency chest radiograph confirmed our diagnosis of a retained fracture of central venous catheter. The retained portion was removed by the interventional radiologist using an endovascular loop snare and delivered through a femoral vein venotomy performed by the surgeon.

    CONCLUSION: Endovascular approach to retrieval of retained fractured catheters has helped tremendously to reduce associated morbidity and the need for major surgery. The role of surgery has become limited to instances of failed endovascular retrieval and in remote geographical locations devoid of such specialty.

    Matched MeSH terms: Endovascular Procedures/methods*
  6. Goh ZNL, Seak JC, Seak CK, Wu CT, Seak CJ
    Medicine (Baltimore), 2019 Aug;98(31):e16645.
    PMID: 31374036 DOI: 10.1097/MD.0000000000016645
    RATIONALE: Abdominal aortic aneurysm is an extremely rare cause of deep vein thrombosis. Here we report an elderly gentleman who presented with deep vein thrombosis and was found to have concomitant abdominal aortic aneurysm upon ultrasonographic screening. It illustrates the possibility of such an aetiology, and the importance of screening for such aneurysms in a select patient population before heparinization.

    PATIENT CONCERNS: A 73-year-old Asian gentleman with underlying hypertension, hyperlipidaemia, chronic renal failure, and history of chronic smoking presented to the emergency department with acute left lower limb swelling of 1 day. On examination, the patient was tachycardic (110 beats/minute) and hypertensive (168/84 millimeters mercury (mmHg)). The entire left lower limb was swollen with notable pitting oedema, tenderness, and warmth; left calf swelling was measured to be 4 centimeters (cm).

    DIAGNOSES: The patient's Wells score of 4 placed him in the high-risk group for deep vein thrombosis. Serum D-dimer was subsequently found to be elevated at 926 nanograms/milliliter (ng/ml). Compression ultrasonography revealed a thrombus in the left deep femoral vein, confirming the diagnosis of deep vein thrombosis. The ultrasonographic evaluation was extended to the abdominal aorta due to the patient's high risk of abdominal aortic aneurysm, and a 7-cm aneurysm was indeed found. Further computed tomography and magnetic resonance imaging localized it to the infrarenal region, with left common iliac vein compression resulting in stagnant venous return.

    INTERVENTIONS: Emergency endovascular repair was performed with insertion of an inferior vena cava filter.

    OUTCOMES: The patient was subsequently monitored in the intensive care unit and uneventfully discharged after 2 weeks.

    LESSONS: Such clinical presentations of deep vein thrombosis are rare, but physicians are reminded to consider screening for abdominal aneurysms and other anatomical causes before heparinization in patients who seemingly do not have thromboembolic risk factors. This is especially so for the high risk group of male deep vein thrombosis patients aged 65-75 years with a history of smoking who have yet to be screened for abdominal aortic aneurysms, in line with United States Preventive Services Task Force recommendations.

    Matched MeSH terms: Endovascular Procedures/methods
  7. Yong YL, Tan LK, McLaughlin RA, Chee KH, Liew YM
    J Biomed Opt, 2017 12;22(12):1-9.
    PMID: 29274144 DOI: 10.1117/1.JBO.22.12.126005
    Intravascular optical coherence tomography (OCT) is an optical imaging modality commonly used in the assessment of coronary artery diseases during percutaneous coronary intervention. Manual segmentation to assess luminal stenosis from OCT pullback scans is challenging and time consuming. We propose a linear-regression convolutional neural network to automatically perform vessel lumen segmentation, parameterized in terms of radial distances from the catheter centroid in polar space. Benchmarked against gold-standard manual segmentation, our proposed algorithm achieves average locational accuracy of the vessel wall of 22 microns, and 0.985 and 0.970 in Dice coefficient and Jaccard similarity index, respectively. The average absolute error of luminal area estimation is 1.38%. The processing rate is 40.6 ms per image, suggesting the potential to be incorporated into a clinical workflow and to provide quantitative assessment of vessel lumen in an intraoperative time frame.
    Matched MeSH terms: Endovascular Procedures/methods*
  8. Leong BD, Naresh G, Hanif H, Lee SK, Zainal AA, Sara CM
    Surg Today, 2013 Aug;43(8):918-22.
    PMID: 22987278 DOI: 10.1007/s00595-012-0330-6
    Open surgical repair of axillosubclavian artery injuries is technically demanding and associated with significant morbidity and mortality. Endovascular intervention has emerged as a valuable alternative to open surgical repair. This report presents three cases with axillosubclavian artery injuries managed with endovascular intervention. All three cases had a pseudoaneurysm of the axillosubclavian artery with one case associated with an arteriovenous fistula. They were successfully treated with endovascular stenting and balloon angioplasty. There were no observed acute complications. No complications or recurrence have occurred, with a mean follow-up of 26 months. Endovascular intervention for axillosubclavian artery injuries is less invasive, safe and effective; however, data concerning the long-term effects and complications associated with this technique are lacking.
    Matched MeSH terms: Endovascular Procedures/methods*
  9. Ambrosanio G, Arthimulam G, Leone G, Guarnieri G, Muto M, Muto M
    World Neurosurg, 2020 10;142:167-170.
    PMID: 32615295 DOI: 10.1016/j.wneu.2020.06.190
    BACKGROUND: Intracranial vascular malformations are increasingly being treated via the endovascular route. Though generally safe, a multitude of intraprocedural complications that potentially lead to disastrous clinical outcomes may arise. It is crucial for the operators to be well versed with the various techniques that are available to overcome any procedure-specific complications.

    METHODS: We present 2 cases in which we encountered premature intravascular detachment of the microcatheter tip and coil migration while treating a dural arteriovenous fistula and aneurysm, respectively. We used a stentriever to remove the detached microcatheter tip and suction using the reperfusion catheter to remove the migrated coil, both techniques that have not been reported in the literature thus far.

    RESULTS: Detached microcatheter tip and migrated coil were successfully retrieved using a stentriever and aspiration catheter.

    CONCLUSIONS: These novel techniques could potentially reduce mortality and morbidity associated with neurointervention.

    Matched MeSH terms: Endovascular Procedures/methods
  10. Noor Khairiah AK, Mohamad Nazrulhisham MN, Hazman MN
    Med J Malaysia, 2018 12;73(6):407-409.
    PMID: 30647215
    Malignant intrathoracic disease is the commonest cause of superior vena cava (SVC) obstruction. Life threatening SVC obstruction with intense dyspnoea requires urgent treatment. SVC stenting has been developed in recent years which results in rapid relief of the obstruction. The Yconfiguration technique has been reported to provide support for all three limbs of the bifurcation to prevent restenosis. At present, there are limited reports on the use of Y-configuration stent in stent techniques for endovascular stenting in malignant SVC obstruction. We share our clinical experience of two patients who received balloon-mounted stents using this technique.
    Matched MeSH terms: Endovascular Procedures/methods
  11. Kawarada O, Zen K, Hozawa K, Ayabe S, Huang HL, Choi D, et al.
    Cardiovasc Interv Ther, 2018 Oct;33(4):297-312.
    PMID: 29654408 DOI: 10.1007/s12928-018-0523-z
    The burden of peripheral artery disease (PAD) and diabetes in Asia is projected to increase. Asia also has the highest incidence and prevalence of end-stage renal disease (ESRD) in the world. Therefore, most Asian patients with PAD might have diabetic PAD or ESRD-related PAD. Given these pandemic conditions, critical limb ischemia (CLI) with diabetes or ESRD, the most advanced and challenging subset of PAD, is an emerging public health issue in Asian countries. Given that diabetic and ESRD-related CLI have complex pathophysiology that involve arterial insufficiency, bacterial infection, neuropathy, and foot deformity, a coordinated approach that involves endovascular therapy and wound care is vital. Recently, there is increasing interaction among cardiologists, vascular surgeons, radiologists, orthopedic surgeons, and plastic surgeons beyond specialty and country boundaries in Asia. This article is intended to share practical Asian multidisciplinary consensus statement on the collaboration between endovascular therapy and wound care for CLI.
    Matched MeSH terms: Endovascular Procedures/methods*
  12. Sia KJ, Ashok GD, Ahmad FM, Kong CK
    Hong Kong Med J, 2013 Dec;19(6):542-4.
    PMID: 24310662 DOI: 10.12809/hkmj133668
    We describe a rare case of aorto-oesophageal fistula and aortic pseudoaneurysm in a middle-aged man, who presented with chest pain and haematemesis 1 week after swallowing a fish bone. Oesophagogastroduodenoscopy and computed tomographic angiography findings were consistent with oesophageal perforation, proximal descending aortic pseudoaneurysm, and aorto-oesophageal fistula. Thoracic endovascular aortic repair was performed. The patient died from severe mediastinal sepsis. Early surgical intervention and broad-spectrum antibiotic therapy are crucial in preventing life-threatening mediastinal infection.
    Matched MeSH terms: Endovascular Procedures/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links