Displaying all 3 publications

Abstract:
Sort:
  1. Lim KG
    Med J Malaysia, 2001 Dec;56(4):513; author reply 513.
    PMID: 12014775
    Comment on: Eng JB. The trans-septal approach to the mitral valve. Med J Malaysia. 2001; 56(2): 236-39.
    Matched MeSH terms: Heart Septum/surgery*
  2. Eng JB
    Med J Malaysia, 2001 Jun;56(2):236-9.
    PMID: 11771086
    To assess the efficacy of the trans-septal approach to the mitral valve, 40 patients who underwent mitral valve surgery via this approach were compared to 37 patients who underwent surgery via the standard left atriotomy. Concomitant procedures included tricuspid annuloplasty, aortic valve replacement, closure of atrial septal defect, coronary artery bypass grafting and aortic valve repair. There was one (1.2%) operative mortality. No patients required pacemaker implantation. Follow-up of up to 18 months showed that all patients were in NYHA classes I and II. One third of the patients who had trans-septal approach to the mitral valve achieved conversion from atrial fibrillation to sinus rhythm while none of the patients who underwent conventional left atriotomy had conversion (p < 0.02). The trans-septal approach to the mitral valve is a useful approach in selective patients requiring mitral valve surgery.
    Comment in: Lim KG. The trans-septal approach to the mitral valve. Med J Malaysia. 2001 Dec;56(4):513
    Matched MeSH terms: Heart Septum/surgery*
  3. Latiff HA, Alwi M, Samion H, Kandhavel G
    Cardiol Young, 2002 May;12(3):224-8.
    PMID: 12365167
    This study reviewed the short-term outcome of transcatheter closure of the defects within the oval fossa using an Amplatzer Septal Occluder. From January 1997 to December 2000, 210 patients with defects within the oval fossa underwent successful transcatheter closure. We reviewed a total of 190 patients with left-to-right shunts, assessing the patients for possible complications and the presence of residual shunts using transthoracic echocardiogram at 24 h, 1 month, 3 months and one year. Their median age was 10 years, with a range from 2 to 64 years, and their median weight was 23.9 kg, with a range from 8.9 to 79 kg. In 5 patients, a patent arterial duct was closed, and in 2 pulmonary balloon valvoplasty performed, at the same sitting. The median size of the Amplatzer device used was 20 mm, with a range from 9 to 36 mm. The median times for the procedure and fluoroscopy were 95 min, with a range from 30 to 210 min, and 18.4 min, with a range from 5 to 144 min, respectively. Mean follow-up was 20.8 +/- 12.4 months. Complete occlusion was obtained in 168 of 190 (88%) patients at 24 h, 128 of 133 (96.2%) at 3 months, and 103 of 104 (99%) at one year. Complications occurred in 4 (2.1%) patients. In one, the device became detached, in the second the device embolized into the right ventricular outflow tract, the lower end of the device straddled in the third, and the final patient had significant bleeding from the site of venupuncture. There were no major complications noted on follow-up. We conclude that transcatheter closure of defects within the oval fossa using the Amplatzer Septal Occluder is safe and effective. Long-term follow-up is required, nonetheless, before it is recommended as a standard procedure.
    Matched MeSH terms: Heart Septum/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links