Displaying all 7 publications

Abstract:
Sort:
  1. Farook TH, Rashid F, Alam MK, Dudley J
    Clin Oral Investig, 2023 Feb;27(2):489-504.
    PMID: 36577849 DOI: 10.1007/s00784-022-04835-w
    BACKGROUND: To explore the digitisation of jaw movement trajectories through devices and discuss the physiological factors and device-dependent variables with their subsequent effects on the jaw movement analyses.

    METHODS: Based on predefined eligibility criteria, the search was conducted following PRISMA-P 2015 guidelines on MEDLINE, EBSCO Host, Scopus, PubMed, and Web of Science databases in 2022 by 2 reviewers. Articles then underwent Cochrane GRADE approach and JBI critical appraisal for certainty of evidence and bias evaluation.

    RESULTS: Thirty articles were included following eligibility screening. Both in vitro experiments (20%) and in vivo (80%) devices ranging from electronic axiography, electromyography, optoelectronic and ultrasonic, oral or extra-oral tracking, photogrammetry, sirognathography, digital pressure sensors, electrognathography, and computerised medical-image tracing were documented. 53.53% of the studies were rated below "moderate" certainty of evidence. Critical appraisal showed 80% case-control investigations failed to address confounding variables while 90% of the included non-randomised experimental studies failed to establish control reference.

    CONCLUSION: Mandibular and condylar growth, kinematic dysfunction of the neuromuscular system, shortened dental arches, previous orthodontic treatment, variations in habitual head posture, temporomandibular joint disorders, fricative phonetics, and to a limited extent parafunctional habits and unbalanced occlusal contact were identified confounding variables that shaped jaw movement trajectories but were not highly dependent on age, gender, or diet. Realistic variations in device accuracy were found between 50 and 330 µm across the digital systems with very low interrater reliability for motion tracing from photographs. Forensic and in vitro simulation devices could not accurately recreate variations in jaw motion and muscle contractions.

    Matched MeSH terms: Jaw Relation Record/methods
  2. Baig MR, Buzayan MM, Yunus N
    J Investig Clin Dent, 2018 May;9(2):e12320.
    PMID: 29349910 DOI: 10.1111/jicd.12320
    AIM: The aim of the present study was to assess the accuracy of multi-unit dental implant casts obtained from two elastomeric impression materials, vinyl polyether silicone (VPES) and polyether (PE), and to test the effect of splinting of impression copings on the accuracy of implant casts.

    METHODS: Forty direct impressions of a mandibular reference model fitted with six dental implants and multibase abutments were made using VPES and PE, and implant casts were poured (N = 20). The VPES and PE groups were split into four subgroups of five each, based on splinting type: (a) no splinting; (b) bite registration polyether; (c) bite registration addition silicone; and (d) autopolymerizing acrylic resin. The accuracy of implant-abutment replica positions was calculated on the experimental casts, in terms of interimplant distances in the x, y, and z-axes, using a coordinate measuring machine; values were compared with those measured on the reference model. Data were analyzed using non-parametrical Kruskal-Wallis and Mann-Whitney tests at α = .05.

    RESULTS: The differences between the two impression materials, VPES and PE, regardless of splinting type, were not statistically significant (P>.05). Non-splinting and splinting groups were also not significantly different for both PE and VPES (P>.05).

    CONCLUSIONS: The accuracy of VPES impression material seemed comparable with PE for multi-implant abutment-level impressions. Splinting had no effect on the accuracy of implant impressions.

    Matched MeSH terms: Jaw Relation Record/methods
  3. Ling BC
    PMID: 11709981
    Standard prosthodontic procedures require five visits to construct a set of complete maxillary and mandibular dentures. Various attempts have been made to reduce these procedures to four or three appointments. However, most of these techniques require the use of visible light polymerized resin as the final denture base materials. Visible light-cured resin materials have inferior physical properties and biocompatibility problems as compared with heat cured polymethylmethacrylate. This paper describes a system of complete denture construction which requires three clinical appointments instead of the usual five visits. This system is made possible by using the VLC base/tray material as the preliminary impression material as well as the application of a new biometric wax occlusion rim. It retains the use of polymethylmethacrylate as the denture base material. This system also utilizes all the procedures used in the conventional five appointment system of complete denture construction.
    Matched MeSH terms: Jaw Relation Record/instrumentation
  4. Ling BC
    Quintessence Int, 2004 Apr;35(4):294-8.
    PMID: 15119715
    This article describes a technique of constructing a set of maxillary and mandibular complete dentures in three visits instead of the usual five clinical appointments. This system of complete-denture construction is made possible because of the combined use of visible light-cured material as an impression tray and record base material, as well as the use of new biometric wax occlusion rims. Unlike some earlier techniques that use light-cured resin composites as the denture base materials, this method retains the use of heat-cured polymethylmethacrylate as the denture base material.
    Matched MeSH terms: Jaw Relation Record/instrumentation
  5. Qamruddin I, Alam MK, Shahid F, Tanveer S, Mukhtiar M, Asim Z
    J Coll Physicians Surg Pak, 2016 May;26(5):390-3.
    PMID: 27225144 DOI: 2321
    OBJECTIVE: To determine and compare the cephalometric values among Pakistani males and females using commonly used sagittal skeletal measurements (ANB, Wits appraisal, Beta-angle) and newly developed cephalometric analyses (Yen-angle and W-angle).

    STUDY DESIGN: Observational, cross-sectional study.

    PLACE AND DURATION OF STUDY: Orthodontic Department of Baqai Medical University, Karachi, Pakistan, from August to October 2013.

    METHODOLOGY: Atotal of 209 pre-treatment lateral cephalometric radiographs of orthodontic patients were selected from departmental records, comprised of 92 males and 117 females. Radiographs were traced for measurements of ANB, Wits appraisal, Beta-angle, W-angle and Yen-angle. Patients were categorized into skeletal classes I, II, and III on the basis of performed measurements, incisor classification, and profile recorded from their records. Descriptive analysis was used to obtain median interquartile range in both the genders and Mann-Whitney U-test was used to observe gender dimorphism.

    RESULTS: Skeletal class II was the most prevalent type of malocclusion. There were no difference in the obtained measurements between males and females except the Wits appraisal and Beta-angle in class II patients, which showed significant difference in values (p < 0.05).

    CONCLUSION: Pakistani population has no significant different difference in the craniofacial morphology of males and females, with the exception of Wits-appraisal and Beta-angle in class II cases.

    Matched MeSH terms: Jaw Relation Record
  6. Baig MR, Gunaseelan R
    J Oral Implantol, 2012 Apr;38(2):149-53.
    PMID: 20932151 DOI: 10.1563/AAID-JOI-D-09-00089
    Passive fit of a long-span screw-retained implant prosthesis is an important criteria for the success of the restoration. This article describes a technique for fabricating a ceramometal implant fixed dental prosthesis (FDP) for a long-span partially edentulous situation by altering the conventional screw-retained design. The possibility of a passive fit is maximized by intraoral luting of the cast frame to milled abutments, and the potential framework distortion during fabrication is compensated to a major extent. Retrievability is ensured by screw retention of the prosthesis to the implants. Compared with conventional porcelain fused to metal screw-retained FDP, this prosthesis is relatively inexpensive to fabricate.
    Matched MeSH terms: Jaw Relation Record
  7. Baig MR, Rajan G
    J Oral Implantol, 2010;36(3):219-23.
    PMID: 20553176 DOI: 10.1563/AAID-JOI-D-09-00048
    Abstract This article describes the clinical and laboratory procedures involved in the fabrication of laboratory-processed, provisional, screw-retained, implant-supported maxillary and mandibular fixed complete dentures incorporating a cast metal reinforcement for immediate loading of implants. Precise fit is achieved by intraoral luting of the cast frame to milled abutments. Effective splinting of all implants is attained by the metal substructure and retrievability is provided by the screw-retention of the prosthesis.
    Matched MeSH terms: Jaw Relation Record
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links