Displaying all 3 publications

Abstract:
Sort:
  1. Foo CY, Lim KK, Sivasampu S, Dahian KB, Goh PP
    BMC Health Serv Res, 2015;15:349.
    PMID: 26315283 DOI: 10.1186/s12913-015-1011-0
    Rising demand of ophthalmology care is increasingly straining Malaysia's public healthcare sector due to its limited human and financial resources. Improving the effectiveness of ophthalmology service delivery can promote national policy goals of population health improvement and system sustainability. This study examined the performance variation of public ophthalmology service in Malaysia, estimated the potential output gain and investigated several factors that might explain the differential performance.
    Matched MeSH terms: Ophthalmology/standards*
  2. Salowi MA, Choong YF, Goh PP, Ismail M, Lim TO
    Br J Ophthalmol, 2010 Apr;94(4):445-9.
    PMID: 19951939 DOI: 10.1136/bjo.2009.163063
    AIMS: To apply cumulative sum (CUSUM) in monitoring performance of surgeons in cataract surgery and to evaluate the response of performance to intervention.
    METHOD: A CUSUM analysis was applied to 80 phacoemulsification performed by three ophthalmic trainees and one consultant, for the occurrence of posterior capsular rupture and postoperative refracted vision of worse than 6/12 among patients without pre-existing ocular comorbidity. The CUSUM score of each consecutive procedure performed by an individual surgeon was calculated and charted on CUSUM chart. When trainees' CUSUM charts showed an unacceptable level of performance, their supervisors would give feedback and impose closer monitoring of subsequent surgeries.
    RESULTS: CUSUM charts of the trainees demonstrated an initial upward followed by flattening trend. This reflects learning curves in their process of acquiring competency in phacoemulsification. In contrast, the consultant showed a flat curve indicating an ongoing maintenance of competence.
    CONCLUSION: The CUSUM analysis is able to monitor and promptly detect adverse events and trends of unacceptable outcomes in cataract surgery. This objective and dynamic monitoring makes CUSUM a useful audit tool for individual surgeons, but more so for busy consultants who need to supervise trainees.
    Matched MeSH terms: Ophthalmology/standards
  3. Mahmud I, Kelley T, Stowell C, Haripriya A, Boman A, Kossler I, et al.
    JAMA Ophthalmol, 2015 Nov;133(11):1247-52.
    PMID: 26291752 DOI: 10.1001/jamaophthalmol.2015.2810
    Aligning outcome measures for cataract surgery, one of the most frequently performed procedures globally, may facilitate international comparisons that can drive improvements in the outcomes most meaningful to patients.
    Matched MeSH terms: Ophthalmology/standards*