Displaying all 2 publications

Abstract:
Sort:
  1. Yam MF, Por LY, Peh KK, Ahmad M, Asmawi MZ, Ang LF, et al.
    Sensors (Basel), 2011;11(5):5058-70.
    PMID: 22163890 DOI: 10.3390/s110505058
    Behavioural assessment of experimental pain is an essential method for analysing and measuring pain levels. Rodent models, which are widely used in behavioural tests, are often subject to external forces and stressful manipulations that cause variability of the parameters measured during the experiment. Therefore, these parameters may be inappropriate as indicators of pain. In this article, a stepping-force analgesimeter was designed to investigate the variations in the stepping force of rats in response to pain induction. The proposed apparatus incorporates new features, namely an infrared charge-coupled device (CCD) camera and a data acquisition system. The camera was able to capture the locomotion of the rats and synchronise the stepping force concurrently so that each step could be identified. Inter-day and intra-day precision and accuracy of each channel (there were a total of eight channels in the analgesimeter and each channel was connected to one load cell and one amplifier) were studied using different standard load weights. The validation studies for each channel also showed convincing results whereby intra-day and inter-day precision were less than 1% and accuracy was 99.36-100.36%. Consequently, an in vivo test was carried out using 16 rats (eight females and eight males). The rats were allowed to randomly walk across the sensor tunnel (the area that contained eight channels) and the stepping force and locomotion were recorded. A non-expert, but from a related research domain, was asked to differentiate the peaks of the front and hind paw, respectively. The results showed that of the total movement generated by the rats, 50.27 ± 3.90% in the case of the male rats and 62.20 ± 6.12% in that of the female rats had more than two peaks, a finding which does not substantiate the assumptions made in previous studies. This study also showed that there was a need to use the video display frame to distinguish between the front and hind paws in the case of 48.80 ± 4.01% of the male rats and 66.76 ± 5.35% of the female rats. Evidently the assumption held by current researchers regarding stepping force measurement is not realistic in terms of application, and as this study has shown, the use of a video display frame is essential for the identification of the front and hind paws through the peak signals.
    Matched MeSH terms: Pain Measurement/instrumentation*
  2. Shariat A, Lam ET, Kargarfard M, Tamrin SB, Danaee M
    Work, 2017;56(3):421-428.
    PMID: 28269804 DOI: 10.3233/WOR-172508
    BACKGROUND: Previous research support the claim that people who work in offices and sit for a long time are particularly prone to musculoskeletal disorders.

    OBJECTIVE: The main objective of this paper is to introduce an exercise training program designed to decrease muscle stiffness and pain that can be performed in the office setting.

    METHODS: Forty healthy office workers (age: 28±5.3 years old; body mass: 87.2±10.2 kg; height: 1.79±0.15 m) apart from suffering from any sub-clinical symptoms of muscle and joint stiffness, and who had at least two years of experience in office work were chosen and randomly assigned to either an experimental group (n = 20) or a control group (n = 20). The experimental group performed the exercise training program three times a week for 11 weeks. The Cornell Musculoskeletal Discomfort Questionnaire was used to measure the pain levels in the neck, shoulders, and lower back areas. The Borg CR-10 Scale was used to measure their perceived exertion when doing the exercises, and a goniometer was used to measure the changes in range of motion (ROM) of the neck, hips, knees, and shoulders.

    RESULTS: The overall results indicated that the exercise program could significantly (p pains of the participants in the exercise group while those in the control group showed no improvement in those pains. There were significant (p pains, but also can improve the ROM or flexibility of the office workers.

    Matched MeSH terms: Pain Measurement/instrumentation
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links