Displaying all 6 publications

Abstract:
Sort:
  1. Shunmugam M, Ang GS, Lois N
    Surv Ophthalmol, 2014 Mar-Apr;59(2):192-216.
    PMID: 24138895 DOI: 10.1016/j.survophthal.2013.03.006
    A giant retinal tear (GRT) is a full-thickness neurosensory retinal break that extends circumferentially around the retina for three or more clock hours in the presence of a posteriorly detached vitreous. Its incidence in large population-based studies has been estimated as 1.5% of rhegmatogenous retinal detachments, with a significant male preponderance, and bilaterality in 12.8%. Most GRTs are idiopathic, with trauma, hereditary vitreoretinopathies and high myopia each being causative in decreasing frequency. The vast majority of GRTs are currently managed with a pars plana vitrectomy; the use of adjunctive circumferential scleral buckling is debated, but no studies have shown a clear anatomical or visual advantage with its use. Similarly, silicone oil tamponade does not influence long-term outcomes when compared with gas. Primary and final retinal reattachment rates are achieved in 88% and 95% of patients, respectively. Even when the retina remains attached, however, visual recovery may be limited. Furthermore, fellow eyes of patients with a GRT are at higher risk of developing retinal tears and retinal detachment. Prophylactic treatment under these circumstances may be considered but there is no firm evidence of its efficacy at the present time.
    Matched MeSH terms: Phacoemulsification/methods
  2. Lam CK, Sundaraj K, Sulaiman MN
    Medicina (Kaunas), 2013;49(1):1-8.
    PMID: 23652710
    The aim of this study was to review the capability of virtual reality simulators in the application of phacoemulsification cataract surgery training. Our review included the scientific publications on cataract surgery simulators that had been developed by different groups of researchers along with commercialized surgical training products, such as EYESI® and PhacoVision®. The review covers the simulation of the main cataract surgery procedures, i.e., corneal incision, capsulorrhexis, phacosculpting, and intraocular lens implantation in various virtual reality surgery simulators. Haptics realism and visual realism of the procedures are the main elements in imitating the actual surgical environment. The involvement of ophthalmology in research on virtual reality since the early 1990s has made a great impact on the development of surgical simulators. Most of the latest cataract surgery training systems are able to offer high fidelity in visual feedback and haptics feedback, but visual realism, such as the rotational movements of an eyeball with response to the force applied by surgical instruments, is still lacking in some of them. The assessment of the surgical tasks carried out on the simulators showed a significant difference in the performance before and after the training.
    Matched MeSH terms: Phacoemulsification/methods*
  3. Naicker P, Sundralingam S, Peyman M, Juana A, Mohamad NF, Win MM, et al.
    Int Ophthalmol, 2015 Aug;35(4):459-66.
    PMID: 25024102 DOI: 10.1007/s10792-014-9970-4
    To determine the accuracy of intraocular lens (IOL) calculations in eyes undergoing phacoemulsification cataract surgery with IOL implantation using immersion A-scan ultrasound (US) and Lenstar LS 900(®) biometry. In this prospective study, 200 eyes of 200 patients were randomized to undergo either Lenstar LS 900(®) or immersion A-scan US biometry to determine the IOL dioptric power prior to phacoemulsification cataract surgery. Post-operative refractive outcomes of these two groups of patients were compared. The result showed no significant difference between the target spherical equivalent (SE) and the post-operative SE value by the Lenstar LS 900(®) (p value = 0.632) or immersion A-scan US biometry (p value = 0.438) devices. The magnitude of difference between the two biometric devices were not significantly different (p value = 0.868). There was no significant difference in the predicted post-operative refractive outcome between immersion A-scan US biometry and Lenstar LS 900(®). Based on the results, the immersion A-scan US technique is as accurate as Lenstar LS 900(®) in the hands of an experienced operator.
    Matched MeSH terms: Phacoemulsification/methods*
  4. Ismail S, Khairy-Shamel ST, Hussein A, Shaharuddin B, Embong Z, Ibrahim M
    J Pediatr Ophthalmol Strabismus, 2010 Mar-Apr;47(2):111-3.
    PMID: 20349906 DOI: 10.3928/01913913-20100308-11
    The authors describe recurrent lens dislocation into the anterior chamber in a young girl with homocystinuria. The patient's 12-year-old sister died after a cerebrovascular accident caused by the same disease. This report highlights the importance of early dietary restrictions and treatment.
    Matched MeSH terms: Phacoemulsification/methods
  5. Ho FL, Salowi MA, Bastion MC
    Asia Pac J Ophthalmol (Phila), 2017;6(5):429-434.
    PMID: 28379650 DOI: 10.22608/APO.2016198
    PURPOSE: To investigate the effects of postoperative eye patching on clear corneal incision architecture in phacoemulsification.

    DESIGN: A single-center, randomized controlled trial.

    METHODS: A total of 132 patients with uncomplicated phacoemulsification were randomly allocated to the intervention or control group. The intervention group received postoperative eye patching for approximately 18 hours, whereas the control group received eye shield. The clear corneal incision architecture was examined postoperatively at 2 hours, 1 day, and 7 days after surgery using optical coherence tomography.

    RESULTS: Epithelial gaping was significantly reduced on postoperative day 1 in the intervention group (52.4%) compared with control (74.2%) (P = 0.01). No differences were found for other architectural defects. Descemet membrane detachment was associated with lower intraocular pressure on postoperative day 7 (P = 0.02). Presence of underlying diabetes mellitus did not seem to influence architectural defects.

    CONCLUSIONS: Postoperative eye patching facilitated epithelial healing and reduced the occurrence of epithelial gaping on postoperative day 1. It may play a role in protecting and improving corneal wounds during the critical immediate postoperative period.

    Matched MeSH terms: Phacoemulsification/methods*
  6. Teoh LS, Foo SW, Mansurali VN, Ang EL, Md Noh UK, Bastion MC
    Asia Pac J Ophthalmol (Phila), 2017;6(4):318-325.
    PMID: 28581284 DOI: 10.22608/APO.2016206
    PURPOSE: To study the effects of intracameral phenylephrine 1.5% on corneal endothelial cell loss and morphological changes in patients who had uneventful phacoemulsification surgery.

    DESIGN: A double-blind randomized controlled trial.

    METHODS: This study comprised 295 patients who were randomized into the intracameral (ICM) mydriatic group or topical mydriatic group. Central corneal endothelial cell density (ECD), coefficient of variation (CV), and percentage of hexagonal cells were measured preoperatively and postoperatively at 1 week, 6 weeks, and 3 months with specular microscope.

    RESULTS: There was no significant difference in endothelial cell density and endothelial cell loss between the topical and ICM mydriatic groups. At 3 months, the mean endothelial cell density in the ICM group was 2129.76 ± 423.53 cells/mm2 and 2100.54 ± 393.00 cells/mm2 in the topical group (P = 0.539). The endothelial cell loss was 18.60 ± 12.79% in the IC M group and 19.44 ± 11.24% in the topical group (P = 0.550). No significant difference was seen in the percentage of hexagonal cells and coefficient of variation of patients between the 2 groups.

    CONCLUSIONS: Intracameral phenylephrine was not associated with increased risk of postoperative endothelial cell loss or morphological changes. It can be safely injected into the anterior chamber for pupil dilatation before phacoemulsification cataract surgery.

    Matched MeSH terms: Phacoemulsification/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links