Displaying all 9 publications

Abstract:
Sort:
  1. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    Am J Phys Med Rehabil, 2014 Sep;93(9):809-23.
    PMID: 24743451 DOI: 10.1097/PHM.0000000000000094
    The purpose of this study was to find the scientific evidence pertaining to various transfemoral suspension systems to provide selection criteria for clinicians. To this end, databases of PubMed, Web of Science, and ScienceDirect were explored. The following key words, as well as their combinations and synonyms, were used for the search: transfemoral prosthesis, prosthetic suspension, lower limb prosthesis, above-knee prosthesis, prosthetic liner, transfemoral, and prosthetic socket. The study design, research instrument, sampling method, outcome measures, and protocols of articles were reviewed. On the basis of the selection criteria, 16 articles (11 prospective studies and 5 surveys) were reviewed. The main causes of reluctance to prosthesis, aside from energy expenditure, were socket-related problems such as discomfort, perspiration, and skin problems. Osseointegration was a suspension option, yet it is rarely applied because of several drawbacks, such as extended rehabilitation process, risk for fracture, and infection along with excessive cost. In conclusion, no clinical evidence was found as a "standard" system of suspension and socket design for all transfemoral amputees. However, among various suspension systems for transfemoral amputees, the soft insert or double socket was favored by most users in terms of function and comfort.
    Matched MeSH terms: Prosthesis Implantation/instrumentation
  2. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Razak NA
    Clin Biomech (Bristol, Avon), 2014 Jan;29(1):87-97.
    PMID: 24315710 DOI: 10.1016/j.clinbiomech.2013.10.013
    Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians.
    Matched MeSH terms: Prosthesis Implantation/instrumentation
  3. Pang YK, Liam CK, Leow CH, Shyamala P, Zal AR
    Med J Malaysia, 2006 Jun;61(2):147-50.
    PMID: 16898303 MyJurnal
    Many studies have shown that tracheobronchial stenting is effective in relieving respiratory distress secondary to major airway obstruction due to lung or oesophageal cancer. A retrospective review on the benefits and complications of self-expandable metallic stent (SEMS) insertion through flexible bronchoscopy for the palliative treatment of upper airway obstruction in University Malaya Medical Centre was performed. Ten patients underwent this procedure. Relief of dyspnoea was immediate following stent insertion in all patients. Stent migration occurred in one patient and three patients had restenosis of the central airway. We conclude that tracheobronchial stenting via flexible bronchoscopy is feasible and safe.
    Matched MeSH terms: Prosthesis Implantation/instrumentation*
  4. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/instrumentation*
  5. Abbas SS, Nasif MS, Al-Waked R, Meor Said MA
    Artif Organs, 2020 Feb;44(2):E20-E39.
    PMID: 31378963 DOI: 10.1111/aor.13536
    Platelet activation induced by shear stresses and non-physiological flow field generated by bileaflet mechanical heart valves (BMHVs) leads to thromboembolism, which can cause fatal consequences. One of the causes of platelet activation could be intermittent regurgitation, which arises due to asynchronous movement and rebound of BMHV leaflets during the valve closing phase. In this numerical study, the effect of intermittent regurgitation on the platelet activation potential of BMHVs was quantified by modeling a BMHV in the straight and anatomic aorta at implantation tilt angles 0°, 5°, 10°, and 20°. A fully implicit Arbitrary Lagrangian-Eulerian-based Fluid-Structure Interaction formulation was adopted with blood modeled as a multiphase, non-Newtonian fluid. Results showed that the intermittent regurgitation and consequently the platelet activation level increases with the increasing implantation tilt of BMHV. For the straight aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 20° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 8.5°, 3°, and 0°, respectively. For the anatomic aorta, the leaflet of the 20° tilted BMHV underwent a rebound of approximately 24° after initially closing, whereas the leaflet of the 10°, 5°, and 0° tilted BMHVs underwent a rebound of 14°, 10°, and 7°, respectively. For all the implantation orientations of BMHVs, intermittent regurgitation and platelet activation were always higher in the anatomic aorta than in the straight aorta. The study concludes that the pivot axis of BMHV must be implanted parallel to the aortic root's curvature to minimize intermittent regurgitation and platelet activation.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/instrumentation*
  6. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/instrumentation*
  7. Sologashvili T, Saat SA, Tille JC, De Valence S, Mugnai D, Giliberto JP, et al.
    Eur J Pharm Biopharm, 2019 Jun;139:272-278.
    PMID: 31004790 DOI: 10.1016/j.ejpb.2019.04.012
    OBJECTIVE: Vascular prostheses for small caliber bypass grafts in cardiac and vascular diseases or for access surgery are still missing. Poly (Ɛ-caprolactone) (PCL) has been previously investigated by our group and showed good biocompatibility and mechanical properties in vitro and rapid endothelialisation, cellular infiltration and vascularisation in vivo yielding optimal patency in the abdominal aortic position. The aim of the present study is to evaluate our PCL graft in the carotid position and to compare its outcome to the grafts implanted in the abdominal aortic position.

    METHODS: PCL grafts (1 mm ID/10 mm long) were implanted into the left common carotid artery in 20 Sprague-Dawley rats and compared to our previously published series of abdominal aortic implants. The animals were followed up to 3, 6, 12 and 24 weeks. At each time point, in vivo compliance, angiography and histological examination with morphology were performed.

    RESULTS: PCL grafts showed good mechanical properties and ease of handling. The average graft compliance was 14.5 ± 1.7%/ mmHg compared to 7.8 ± 0.9% for the abdominal position and 45.1 ± 3.2%/ mmHg for the native carotid artery. The overall patency for the carotid position was 65% as compared to 100% in the abdominal position. Complete endothelialisation was achieved at 3 weeks and cell invasion was more rapid than in the aortic position. In contrast, intimal hyperplasia (IH) and vascular density were less pronounced than in the aortic position.

    CONCLUSION: Our PCL grafts in the carotid position were well endothelialised with early cellular infiltration, higher compliance, lower IH and calcification compared to the similar grafts implanted in the aortic position. However, there was a higher occlusion rate compared to our abdominal aorta series. Anatomical position, compliance mismatch, flow conditions may answer the difference in patency seen.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/instrumentation
  8. El-Chami MF, Clementy N, Garweg C, Omar R, Duray GZ, Gornick CC, et al.
    JACC Clin Electrophysiol, 2019 02;5(2):162-170.
    PMID: 30784685 DOI: 10.1016/j.jacep.2018.12.008
    OBJECTIVES: This study sought to report periprocedural outcomes and intermediate-term follow-up of hemodialysis patients undergoing Micra implantation.

    BACKGROUND: Leadless pacemakers may be preferred in patients with limited vascular access and high-infection risk, such as patients on hemodialysis.

    METHODS: Patients on hemodialysis at the time of Micra implantation attempt (n = 201 of 2,819; 7%) from the Micra Transcatheter Pacing Study investigational device exemption trial, Micra Transcatheter Pacing System Continued Access Study Protocol, and Micra Transcatheter Pacing System Post-Approval Registry were included in the analysis. Baseline characteristics, periprocedural outcomes, and intermediate-term follow-up were summarized.

    RESULTS: Patients on hemodialysis at the time of Micra implantation attempt were on average 70.5 ± 13.5 years of age and 59.2% were male. The dialysis patients commonly had hypertension (80%), diabetes (61%), coronary artery disease (39%), and congestive heart failure (27%), and 72% had a condition that the implanting physician felt precluded the use of a transvenous pacemaker. Micra was successfully implanted in 197 patients (98.0%). Reasons for unsuccessful implantation included inadequate thresholds (n = 2) and pericardial effusion (n = 2). The median implantation time was 27 min (interquartile range: 20 to 39 min). There were 3 procedure-related deaths: 1 due to metabolic acidosis following a prolonged procedure duration in a patient undergoing concomitant atrioventricular nodal ablation and 2 deaths occurred in patients who needed surgical repair after perforation. Average follow-up was 6.2 months (range 0 to 26.7 months). No patients had a device-related infection or required device removal because of bacteremia.

    CONCLUSIONS: Leadless pacemakers represent an effective pacing option in this challenging patient population on chronic hemodialysis. The risk of infection appears low with an acceptable safety profile. (Micra Transcatheter Pacing Study; NCT02004873; Micra Transcatheter Pacing System Continued Access Study Protocol; NCT02488681; Micra Transcatheter Pacing System Post-Approval Registry; NCT02536118).

    Matched MeSH terms: Prosthesis Implantation/instrumentation
  9. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Heart Valve Prosthesis Implantation/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links