Displaying all 5 publications

Abstract:
Sort:
  1. Qureshi AU, Abbaker AE, Sivalingam S, Latiff HA
    PMID: 24668992 DOI: 10.1177/2150135113509819
    Valved bovine jugular vein (Contegra) conduit is considered a suitable choice for pediatric population with congenital heart defect requiring right ventricle to main pulmonary artery connection. Intermediate follow-up studies have shown the propensity of developing distal conduit stenosis and valve thrombosis. We present a rare case of aneurysmal dilatation of the conduit leading to valve failure requiring conduit explantation.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects*
  2. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects
  3. Promphan W, Han Siang K, Prachasilchai P, Jarutach J, Makonkawkeyoon K, Siwaprapakorn W, et al.
    Catheter Cardiovasc Interv, 2020 09 01;96(3):E310-E316.
    PMID: 32299151 DOI: 10.1002/ccd.28892
    OBJECTIVES: To assess feasibility and early outcomes of using BeGraft Aortic stent in the treatment of aortic coarctation (CoA).

    BACKGROUND: BeGraft Aortic stent (Bentley InnoMed, Hechingen, Germany) allows large postdilation diameter up to 30 mm. With availability of lengths of 19-59 mm and lower stent profile, they can be used in native and recurrent CoA in adults and in pediatric patients.

    MATERIALS AND METHODS: This is a multicentre retrospective analysis of 12 implanted BeGraft Aortic stents in CoA between May 2017 and April 2019.

    RESULTS: Twelve patients aged 7.7-38 years (median 18.3 years) with body weight of 19.9-56 kg (median 45.5 kg). Eight patients (66%) had native juxtaductal CoA while four had recurrent CoA after previous surgical or transcatheter treatments. The stents were implanted successfully in all the patients with no serious adverse events. The length of the stents ranged from 27 to 59 mm and the implanted stent diameter varied from 12 to 18 mm. The median intraprocedural CoA pressure gradient decreased from 25 mmHg (range 16-66 mmHg) to 2 mmHg (range 0-13 mmHg). The mean follow-up duration was 10.2 months. Two patient (16.6%) had residual stent narrowing requiring staged redilation. One patient (8%) had pseudoaneurysm formation at 1 year cardiac CT follow-up.

    CONCLUSIONS: The BeGraft Aortic stent may be considered to be safe and effective in the short term in treatment of CoA from childhood to adulthood. Long-term follow-up is needed.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects
  4. Sologashvili T, Saat SA, Tille JC, De Valence S, Mugnai D, Giliberto JP, et al.
    Eur J Pharm Biopharm, 2019 Jun;139:272-278.
    PMID: 31004790 DOI: 10.1016/j.ejpb.2019.04.012
    OBJECTIVE: Vascular prostheses for small caliber bypass grafts in cardiac and vascular diseases or for access surgery are still missing. Poly (Ɛ-caprolactone) (PCL) has been previously investigated by our group and showed good biocompatibility and mechanical properties in vitro and rapid endothelialisation, cellular infiltration and vascularisation in vivo yielding optimal patency in the abdominal aortic position. The aim of the present study is to evaluate our PCL graft in the carotid position and to compare its outcome to the grafts implanted in the abdominal aortic position.

    METHODS: PCL grafts (1 mm ID/10 mm long) were implanted into the left common carotid artery in 20 Sprague-Dawley rats and compared to our previously published series of abdominal aortic implants. The animals were followed up to 3, 6, 12 and 24 weeks. At each time point, in vivo compliance, angiography and histological examination with morphology were performed.

    RESULTS: PCL grafts showed good mechanical properties and ease of handling. The average graft compliance was 14.5 ± 1.7%/ mmHg compared to 7.8 ± 0.9% for the abdominal position and 45.1 ± 3.2%/ mmHg for the native carotid artery. The overall patency for the carotid position was 65% as compared to 100% in the abdominal position. Complete endothelialisation was achieved at 3 weeks and cell invasion was more rapid than in the aortic position. In contrast, intimal hyperplasia (IH) and vascular density were less pronounced than in the aortic position.

    CONCLUSION: Our PCL grafts in the carotid position were well endothelialised with early cellular infiltration, higher compliance, lower IH and calcification compared to the similar grafts implanted in the aortic position. However, there was a higher occlusion rate compared to our abdominal aorta series. Anatomical position, compliance mismatch, flow conditions may answer the difference in patency seen.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects
  5. Zubaidah NH, Azim MI, Osama MH, Harunarashid H, Das S
    Clin Ter, 2012;163(1):27-9.
    PMID: 22362230
    The incidence of infection following TEVAR is low. To the best of our knowledge, this is the first case report of post thoracic endovascular aortic repair (TEVAR) with Streptococcus viridans graft infection. A 54-year-old male underwent TEVAR for dissecting thoracic aneurysm with spinal ischaemia. He had an eventful recovery with prolonged period of stay in intensive care unit. Three months later, he presented with persistent chest discomfort and fever. Computed tomography (CT) of the thorax revealed evidence of graft infection and the blood culture grew Streptococcus viridans. The rarity of TEVAR graft infection due to Streptococcus viridans and its management are being discussed.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links