  1. Kanagasingam S, Hussaini HM, Soo I, Baharin S, Ashar A, Patel S
    Int Endod J, 2017 May;50(5):427-436.
    PMID: 27063356 DOI: 10.1111/iej.12651
    AIM: To compare the accuracy of film and digital periapical radiography (PR) in detecting apical periodontitis (AP) using histopathological findings as a reference standard.

    METHODOLOGY: Jaw sections containing 67 teeth (86 roots) were collected from nine fresh, unclaimed bodies that were due for cremation. Imaging was carried out to detect AP lesions using film and digital PR with a centred view (FP and DP groups); film and digital PR combining central with 10˚ mesially and distally angled (parallax) views (FPS and DPS groups). All specimens underwent histopathological examination to confirm the diagnosis of AP. Sensitivity, specificity and predictive values of PR were analysed using rater mean (n = 5). Receiver operating characteristics (ROC) analysis was carried out.

    RESULTS: Sensitivity was 0.16, 0.37, 0.27 and 0.38 for FP, FPS, DP and DPS, respectively. Both FP and FPS had specificity and positive predictive values of 1.0, whilst DP and DPS had specificity and positive predictive values of 0.99. Negative predictive value was 0.36, 0.43, 0.39 and 0.44 for FP, FPS, DP and DPS, respectively. Area under the curve (AUC) for the various imaging methods was 0.562 (FP), 0.629 (DP), 0.685 (FPS), 0.6880 (DPS).

    CONCLUSIONS: The diagnostic accuracy of single digital periapical radiography was significantly better than single film periapical radiography. The inclusion of two additional horizontal (parallax) angulated periapical radiograph images (mesial and distal horizontal angulations) significantly improved detection of apical periodontitis.

    Matched MeSH terms: Radiography, Dental, Digital/methods*
  2. Ghazali L, Mohd Yusof MYP, Norman NH
    J Orthod, 2021 03;48(1):5-12.
    PMID: 33200660 DOI: 10.1177/1465312520971641
    OBJECTIVES: To investigate the effect of reducing scanning parameters of digital dental panoramic tomogram (DPT) and lateral cephalometric (LC) radiographs on quality and diagnostic performance of the images.

    DESIGN: Single-centre prospective two-arm parallel randomised controlled trial.

    SETTING: Orthodontic Clinic, Faculty of Dentistry, Universiti Teknologi MARA, Selangor, Malaysia.

    PARTICIPANTS: Adult orthodontic patients aged 18-35 years, indicated for DPT and LC, who were fit and healthy with a body mass index of 18.5-25.0, not contraindicated to radiographic examination, not pregnant, and did not have a history of facial or skeletal abnormalities or bone diseases were included.

    METHODS: Thirty-eight adult orthodontic patients were randomised into control and intervention groups. DPT and LC radiographs in the control group were obtained using standard scanning parameters as prescribed by the manufacturer using Orthopantomograph® OP300 by Instrumentarium. Scanning parameters in the intervention group were reduced by 60% for DPT (60 kV, 3.2 mA) and 30% for LC (85 kV, 8 mA). A five-point rating scale was used for the assessment of image quality. Images were evaluated for diagnostic performance by detection of anatomical landmarks. Mann-Whitney test was performed to compare the quality and diagnostic performance of the images and the observer agreement was assessed using the intraclass correlation coefficient (ICC).

    RESULTS: For image quality, the control group produced slightly lower median scores (DPT 2.0, LC 2.0) compared to the intervention group (DPT 2.0, LC 3.0). For diagnostic performance, both groups showed similar median scores (DPT 21.0, LC 32.0). The differences between control and intervention groups for both modalities were not statistically significant. The average scores for intra-observer agreement were excellent (ICC 0.917) and inter-observer agreement was good (ICC 0.822).

    CONCLUSION: Minimising radiation exposure by reducing scanning parameters on digital DPT by 60% and LC by 30% on Intsrumentarium 300 OP did not affect the quality and diagnostic performance of the images. Thus, scanning parameters on digital DPT and LC should be reduced when taking radiographs.

    Matched MeSH terms: Radiography, Dental, Digital*
  3. Nawi N, Mohamed AM, Marizan Nor M, Ashar NA
    J Orofac Orthop, 2018 Jan;79(1):19-27.
    PMID: 29116344 DOI: 10.1007/s00056-017-0111-3
    OBJECTIVE: The aim of the present study was to determine the overall reliability and validity of arch parameters measured digitally compared to conventional measurement.

    METHODS: A sample of 111 plaster study models of Down syndrome (DS) patients were digitized using a blue light three-dimensional (3D) scanner. Digital and manual measurements of defined parameters were performed using Geomagic analysis software (Geomagic Studio 2014 software, 3D Systems, Rock Hill, SC, USA) on digital models and with a digital calliper (Tuten, Germany) on plaster study models. Both measurements were repeated twice to validate the intraexaminer reliability based on intraclass correlation coefficients (ICCs) using the independent t test and Pearson's correlation, respectively. The Bland-Altman method of analysis was used to evaluate the agreement of the measurement between the digital and plaster models.

    RESULTS: No statistically significant differences (p > 0.05) were found between the manual and digital methods when measuring the arch width, arch length, and space analysis. In addition, all parameters showed a significant correlation coefficient (r ≥ 0.972; p 

    Matched MeSH terms: Radiography, Dental, Digital*
  4. Sabarudin A, Tiau YJ
    Quant Imaging Med Surg, 2013 Feb;3(1):43-8.
    PMID: 23483085 DOI: 10.3978/j.issn.2223-4292.2013.02.07
    This study is designed to compare and evaluate the diagnostic image quality of dental panoramic radiography between conventional and digital systems. Fifty-four panoramic images were collected and divided into three groups consisting of conventional, digital with and without post processing image. Each image was printed out and scored subjectively by two experienced dentists who were blinded to the exposure parameters and system protocols. The evaluation covers of anatomical coverage and structures, density and image contrast. The overall image quality score revealed that digital panoramic with post-processing scored the highest of 3.45±0.19, followed by digital panoramic system without post-processing and conventional panoramic system with corresponding scores of 3.33±0.33 and 2.06±0.40. In conclusion, images produced by digital panoramic system are better in diagnostic image quality than that from conventional panoramic system. Digital post-processing visualization can improve diagnostic quality significantly in terms of radiographic density and contrast.
    Matched MeSH terms: Radiography, Dental, Digital
  5. Kanagasingam S, Lim CX, Yong CP, Mannocci F, Patel S
    Int Endod J, 2017 May;50(5):417-426.
    PMID: 27063209 DOI: 10.1111/iej.12650
    AIM: To compare the diagnostic accuracy of periapical radiography (PR) and cone beam computed tomography (CBCT) in detecting apical periodontitis (AP) using histopathological findings as a reference standard.

    METHODOLOGY: Jaw sections containing 67 teeth (86 roots) were collected from unclaimed bodies due for cremation. Imaging was carried out to detect AP by digital PR with a central view (DP group), digital PR combining central with 10˚ mesially and distally angled (parallax) views (DPS group) and CBCT scans. All specimens underwent histopathological examination to confirm the diagnosis of AP. Sensitivity, specificity and predictive values of PR and CBCT were analysed using rater mean (n = 5). Receiver-operating characteristic (ROC) analysis was carried out.

    RESULTS: Sensitivity was 0.27, 0.38 and 0.89 for DP, DPS and CBCT scans, respectively. CBCT had specificity and positive predictive value of 1.0 whilst DP and DPS had specificity and positive predictive value of 0.99. The negative predictive value was 0.39, 0.44 and 0.81 for DP, DPS and CBCT scans, respectively. Area under the curve (AUC) for the various imaging methods was 0.629 (DP), 0.688 (DPS), and 0.943 (CBCT).

    CONCLUSIONS: All imaging techniques had similar specificity and positive predictive values. Additional parallax views increased the diagnostic accuracy of PR. CBCT had significantly higher diagnostic accuracy in detecting AP compared to PR, using human histopathological findings as a reference standard.

    Matched MeSH terms: Radiography, Dental, Digital/methods*
  6. Mosleh MA, Baba MS, Malek S, Almaktari RA
    BMC Bioinformatics, 2016 Dec 22;17(Suppl 19):499.
    PMID: 28155649 DOI: 10.1186/s12859-016-1370-5
    BACKGROUND: Cephalometric analysis and measurements of skull parameters using X-Ray images plays an important role in predicating and monitoring orthodontic treatment. Manual analysis and measurements of cephalometric is considered tedious, time consuming, and subjected to human errors. Several cephalometric systems have been developed to automate the cephalometric procedure; however, no clear insights have been reported about reliability, performance, and usability of those systems. This study utilizes some techniques to evaluate reliability, performance, and usability metric using SUS methods of the developed cephalometric system which has not been reported in previous studies.

    METHODS: In this study a novel system named Ceph-X is developed to computerize the manual tasks of orthodontics during cephalometric measurements. Ceph-X is developed by using image processing techniques with three main models: enhancements X-ray image model, locating landmark model, and computation model. Ceph-X was then evaluated by using X-ray images of 30 subjects (male and female) obtained from University of Malaya hospital. Three orthodontics specialists were involved in the evaluation of accuracy to avoid intra examiner error, and performance for Ceph-X, and 20 orthodontics specialists were involved in the evaluation of the usability, and user satisfaction for Ceph-X by using the SUS approach.

    RESULTS: Statistical analysis for the comparison between the manual and automatic cephalometric approaches showed that Ceph-X achieved a great accuracy approximately 96.6%, with an acceptable errors variation approximately less than 0.5 mm, and 1°. Results showed that Ceph-X increased the specialist performance, and minimized the processing time to obtain cephalometric measurements of human skull. Furthermore, SUS analysis approach showed that Ceph-X has an excellent usability user's feedback.

    CONCLUSIONS: The Ceph-X has proved its reliability, performance, and usability to be used by orthodontists for the analysis, diagnosis, and treatment of cephalometric.

    Matched MeSH terms: Radiography, Dental, Digital/methods*
  7. Kumaresan R, Cugati N, Chandrasekaran B, Karthikeyan P
    J Investig Clin Dent, 2016 Feb;7(1):102-9.
    PMID: 25048008 DOI: 10.1111/jicd.12116
    OBJECTIVE: To evaluate the reliability and validity of Demirjian's, Willems, Nolla's, Haavikko's, and Cameriere's radiographic methods of dental-age estimation in a population of Malaysian children.

    METHODS: A total of 426 dental panoramic radiographs of 5-15-year-old Malaysian children were included in the study. The mean age error and absolute age error for all the methods were calculated and their usability analyzed.

    RESULTS: The Nolla, Willems. and Demirjian methods overestimated the dental age with a mean of 0.97, 0.54, and 0.54 years, respectively, while the Cameriere and Haavikko methods underestimated by 0.41 and 1.31 years, respectively. The Cameriere method was highly precise and accurate in the population of Malaysian children, whereas the Haavikko and Demirjian methods were the least precise and accurate.

    CONCLUSIONS: The Cameriere method of dental-age estimation is highly valid and reliable for Malaysian population, followed by the Willems and Nolla methods.

    Matched MeSH terms: Radiography, Dental, Digital
  8. Al-Juboori MJ, AbdulRahaman SB, Hassan A
    Implant Dent, 2013 Aug;22(4):351-5.
    PMID: 23811720 DOI: 10.1097/ID.0b013e318296583d
    To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA).
    Matched MeSH terms: Radiography, Dental, Digital/methods
  9. Nik-Hussein NN, Kee KM, Gan P
    Forensic Sci Int, 2011 Jan 30;204(1-3):208.e1-6.
    PMID: 20869825 DOI: 10.1016/j.forsciint.2010.08.020
    BACKGROUND: One of the most commonly used method for dental age assessment is the method reported by Demirjian and coworkers in 1973. It was later modified by Willems and coworkers whereby they “performed a weighted ANOVA” in order to adapt the scoring system.
    AIM: To evaluate the applicability of Demirjian and Willems methods for dental age estimation for Malaysian children and to correlate the accuracy of the findings with the chronology of tooth development of premolars and second molars.
    MATERIALS AND METHODS: A total of 991 dental panoramic radiographs of 5-15-year-old Malaysian children were included in the study. The mean Demirjian and Willems estimated ages were compared to the mean chronological age.
    RESULTS: The mean chronological age of the sample was 10.1±2.8 and 9.9±3.0 years for males and females respectively. Using the Demirjian method, the mean estimated dental age was 10.8±2.9 years for males and 10.5±2.9 years for females. For Willems method, the mean estimated age was 10.3±2.8 years males and 10.0±3.0 years respectively.
    CONCLUSIONS: Willems method was more applicable for estimating dental age for Malaysian children. Overestimation in Demirjian method could be due to advanced development of second bicuspids and molars.
    Matched MeSH terms: Radiography, Dental, Digital
  10. Jayaraman J, Wong HM, King NM, Roberts GJ
    J Forensic Leg Med, 2016 Oct;43:26-33.
    PMID: 27441983 DOI: 10.1016/j.jflm.2016.07.007
    BACKGROUND: Many countries have recently experienced a rapid increase in the demand for forensic age estimates of unaccompanied minors. Hong Kong is a major tourist and business center where there has been an increase in the number of people intercepted with false travel documents. An accurate estimation of age is only possible when a dataset for age estimation that has been derived from the corresponding ethnic population. Thus, the aim of this study was to develop and validate a Reference Data Set (RDS) for dental age estimation for southern Chinese.

    MATERIALS AND METHODS: A total of 2306 subjects were selected from the patient archives of a large dental hospital and the chronological age for each subject was recorded. This age was assigned to each specific stage of dental development for each tooth to create a RDS. To validate this RDS, a further 484 subjects were randomly chosen from the patient archives and their dental age was assessed based on the scores from the RDS. Dental age was estimated using meta-analysis command corresponding to random effects statistical model. Chronological age (CA) and Dental Age (DA) were compared using the paired t-test.

    RESULTS: The overall difference between the chronological and dental age (CA-DA) was 0.05 years (2.6 weeks) for males and 0.03 years (1.6 weeks) for females. The paired t-test indicated that there was no statistically significant difference between the chronological and dental age (p > 0.05).

    CONCLUSION: The validated southern Chinese reference dataset based on dental maturation accurately estimated the chronological age.

    Matched MeSH terms: Radiography, Dental, Digital
  11. Lim MY, Lim WW, Rajan S, Nambiar P, Ngeow WC
    Eur Arch Paediatr Dent, 2015 Oct;16(5):397-407.
    PMID: 25894248 DOI: 10.1007/s40368-015-0184-x
    To observe age-related changes in the locations of mandibular foramen (MF) and mental foramen (mf) using dental panoramic tomographs (DPTs).
    Matched MeSH terms: Radiography, Dental, Digital/methods
  12. Surendran S, Thomas E
    Am J Orthod Dentofacial Orthop, 2014 Jan;145(1):7-14.
    PMID: 24373650 DOI: 10.1016/j.ajodo.2013.09.007
    The objective of this study was to determine whether dental calcification can be used as a first-level diagnostic tool for assessment of skeletal maturity.
    Matched MeSH terms: Radiography, Dental, Digital/methods