Displaying all 3 publications

Abstract:
Sort:
  1. Rajananda V, Nair NK, Navaratnam V
    Bull Narc, 1985 Jan-Mar;37(1):35-47.
    PMID: 4063572
    The authors selected 38 thin-layer-chromatography (TLC) systems described in the available literature published over the last 10 years and evaluated those systems with respect to their suitability for detection and identification of opiates in urine, opium and heroin, as well as adulterants in heroin. A total of 14 substances: 8 opiates (morphine, 6-monoacetylmorphine, diacetylmorphine, codeine, acetylcodeine, noscapine, papaverine and thebaine) and 6 adulterants (ephedrine, quinine, methadone, caffeine, cocaine and strychnine) were used as test samples for this research. Using laboratory-coated plates and pre-coated plates, 15 and 13 TLC systems, respectively, were found to be able to detect and identify morphine and codeine in urine without interference from the remaining 12 substances. For the detection of opiates in opium samples as well as opiates and adulterants in illicit heroin samples the TLC system: chloroform-n-hexane-triethylamine (9:9:4) which was developed by the National Drug Research Centre, Penang, Malaysia, was found to be most suitable on both laboratory-coated and pre-coated plates. In addition, the following two systems, one on laboratory-coated plates--hexane-chloroform-diethylamine (50:30:7)--and the other on pre-coated plates--benzene-dioxane-ethanol-ammonia (50:40:5:5; T-7)--were also found to be among most suitable TLC systems for the analysis of opiates in opium samples. The article also presents the relative cost of each of the 38 evaluated TLC systems.
    Matched MeSH terms: Street Drugs/analysis
  2. Chang ET, Lim BH
    Med J Malaysia, 1989 Jun;44(2):160-6.
    PMID: 2626126
    The abuse of phenylbutazone among rheumatoid arthritis patients has recently become a subject of interest. Unscrupulous manufacturers take advantage of the miraculous analgesic property of phenylbutazone and deliberately add this toxic drug in their preparations without declaring its presence on the label. In a recent survey, many such illicit preparations were seized from Chinese medical halls in Johor and sent to the Department of Chemistry, Johor Bahru for analysis. Here a Gas Chromatograph Mass Selective Detector (GC-MSD) method was developed for the determination of phenylbutazone in illicit traditional preparations.
    Matched MeSH terms: Street Drugs/analysis*
  3. Sulaiman M, Kunalan V, Yap ATW, Lim WJL, Ng JJY, Loh SWX, et al.
    Drug Test Anal, 2018 Jan;10(1):109-119.
    PMID: 28670869 DOI: 10.1002/dta.2238
    Clandestine heroin laboratories have been a feature of the Malaysian illicit drug scene since soon after the abuse of heroin emerged in 1972. The first few clandestine heroin laboratories which synthesised heroin via the acetylation of imported morphine were uncovered in 1973 and 1977. By the mid-1980s, this type of laboratory was replaced by heroin-cutting laboratories whereby imported high-grade heroin was cut to street heroin. This was to meet the rising demand for the drug owing to the rapid escalation of the number of drug users. Over the years, the most significant change in the composition of the street heroin is the decrease in its purity from 30%-50% to 3%-5%. Caffeine has remained the major adulterant and chloroquine is detected in virtually all recent seizures.
    Matched MeSH terms: Street Drugs/analysis
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links