Displaying all 3 publications

Abstract:
Sort:
  1. Azmi NE, Ramli NI, Abdullah J, Abdul Hamid MA, Sidek H, Abd Rahman S, et al.
    Biosens Bioelectron, 2015 May 15;67:129-33.
    PMID: 25113659 DOI: 10.1016/j.bios.2014.07.056
    A novel optical detection system consisting of combination of uricase/HRP-CdS quantum dots (QDs) for the determination of uric acid in urine sample is described. The QDs was used as an indicator to reveal fluorescence property of the system resulting from enzymatic reaction of uricase and HRP (horseradish peroxidase), which is involved in oxidizing uric acid to allaintoin and hydrogen peroxide. The hydrogen peroxide produced was able to quench the QDs fluorescence, which was proportional to uric acid concentration. The system demonstrated sufficient activity of uricase and HRP at a ratio of 5U:5U and pH 7.0. The linearity of the system toward uric acid was in the concentration range of 125-1000 µM with detection limit of 125 µM.
    Matched MeSH terms: Uric Acid/chemistry
  2. Ghadimi H, Tehrani RM, Ali AS, Mohamed N, Ab Ghani S
    Anal Chim Acta, 2013 Feb 26;765:70-6.
    PMID: 23410628 DOI: 10.1016/j.aca.2012.12.039
    A novel glassy carbon electrode (GCE) modified with a composite film of poly (4-vinylpyridine) (P4VP) and multiwalled carbon nanotubes (P4VP/MWCNT GCE) was used for the voltammetric determination of paracetamol (PCT). This novel electrode displayed a combined effect of P4VP and MWCNT on the electro-oxidation of PCT in a solution of phosphate buffer at pH 7. Hence, conducting properties of P4VP along with the remarkable physical properties of MWCNTs might have combined effects in enhancing the kinetics of PCT oxidation. The P4VP/MWCNT GCE has also demonstrated excellent electrochemical activity toward PCT oxidation compared to that with bare GCE and MWCNT GCE. The anodic peak currents of PCT on the P4VP/MWCNT GCE were about 300 fold higher than that of the non-modified electrodes. By applying differential pulse voltammetry technique under optimized experimental conditions, a good linear ratio of oxidation peak currents and concentrations of PCT over the range of 0.02-450 μM with a limit of detection of 1.69 nM were achieved. This novel electrode was stable for more than 60 days and reproducible responses were obtained at 99% of the initial current of PCT without any influence of physiologically common interferences such as ascorbic acid and uric acid. The application of this electrode to determine PCT in tablets and urine samples was proposed.
    Matched MeSH terms: Uric Acid/chemistry
  3. Saeed OA, Sazili AQ, Akit H, Alimon AR, Samsudin AAB
    Trop Anim Health Prod, 2018 Dec;50(8):1859-1864.
    PMID: 29948778 DOI: 10.1007/s11250-018-1636-1
    This study investigated the effect of different levels of corn supplementation as energy source into palm kernel cake-urea-treated rice straw basal diet on urinary excretion of purine derivatives, nitrogen utilization, rumen fermentation, and rumen microorganism populations. Twenty-seven Dorper lambs were randomly assigned to three treatment groups and kept in individual pens for a 120-day period. The animals were subjected to the dietary treatments as follows: T1: 75.3% PKC + 0% corn, T2: 70.3% PKC + 5% corn, and T3: 65.3% PKC + 10% corn. Hypoxanthine and uric acid excretion level were recorded similarly in lambs supplemented with corn. The microbial N yield and butyrate level was higher in corn-supplemented group, but fecal N excretion, T3 has the lowest level than other groups. Lambs fed T3 had a greater rumen protozoa population while the number of R. flavefaciens was recorded highest in T2. No significant differences were observed for total bacteria, F. succinogenes, R. albus, and methanogen population among all treatment. Based on these results, T3 could be fed to lambs without deleterious effect on the VFA and N balance.
    Matched MeSH terms: Uric Acid/chemistry
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links