Abstract:
Sort:
  1. Ismail NA, Saharan WS, Zaleha MA, Jaafar R, Muhammad JA, Razi ZR
    J Obstet Gynaecol Res, 2008 Jun;34(3):350-3.
    PMID: 18686348
    AIM: To compare the success, clinical outcomes, and maternal and neonatal complications between the Kiwi Omnicup and the Malmstrom metal cup in vacuum assisted delivery.

    METHODS: This was a prospective randomized comparative trial. Women who required vacuum assisted vaginal delivery were randomized into the Kiwi Omnicup (KO) group and the Malmstrom metal cup (MM) group. The vacuum assisted deliveries were conducted according to hospital protocol. Details of the procedure and delivery outcomes including success and complications were analyzed.

    RESULTS: One hundred and sixty-four women were recruited - 85 were assigned to vacuum assisted delivery using the KO and 79 the MM. One hundred percent delivery success was achieved with no significant differences between the two instruments in terms of maternal morbidity (P = 0.66). Six women in the MM group sustained post delivery complications in comparison to five in the KO group. Three babies were diagnosed with birth asphyxia in each group. More babies in the MM group were admitted to the Neonatal Intensive Care Unit (NICU) (10 babies versus 5 babies) and suffered complications (14 versus 12 babies), compared to the KO group, although the difference was not statistically significant. There were no intrapartum or neonatal deaths and of those admitted to the NICU, all were discharged within a week without any serious consequences.

    CONCLUSION: Kiwi Omnicup is an effective alternative to the currently available Malmstrom metal cup for vacuum assisted delivery with no increase in maternal or neonatal morbidity or mortality.

    Matched MeSH terms: Vacuum Extraction, Obstetrical/instrumentation*
  2. Ghani AR, Prakash RG, Abdullah J
    Med J Malaysia, 2006 Mar;61(1):100-2.
    PMID: 16708744 MyJurnal
    We report one case of posterior fossa intracranial haemorrhage in a full-term Malay baby boy following vacuum assisted delivery. The patient, a term baby boy was delivered by a vacuum extraction and later developed signs of increased intracranial pressure 72 hours after birth. Computed tomography (CT) of the brain showed a posterior fossa intracranial haemorrhage with acute obstructive hydrocephalus. He was initially treated with isolated ventricular shunting which later caused an upward cerebellar herniation. An immediate suboccipital craniectomy for evacuation of cerebellar haematoma was performed which resulted in a gradual recovery.
    Matched MeSH terms: Vacuum Extraction, Obstetrical/instrumentation