Displaying all 3 publications

Abstract:
Sort:
  1. Yuen KH, Choy WP, Tan HY, Wong JW, Yap SP
    J Pharm Biomed Anal, 2001 Feb;24(4):715-9.
    PMID: 11272330
    A simple high-performance liquid chromatographic method was developed for the determination of omeprazole in human plasma. Omeprazole and the internal standard, chloramphenicol, were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M Na2HPO4-ACN (65:35, v/v) adjusted to pH 6.5. Analysis was run at a flow rate of 1.0 ml/min at a detection wavelength of 302 nm. The method was specific and sensitive with a detection limit of 2.5 ng/ml at a signal-to-noise ratio of 4:1. The limit of quantification was set at 5 ng/ml. The calibration curve was linear over a concentration range of 5-1280 ng/ml. Mean recovery value of the extraction procedure was about 96%, while the within and between day coefficient of variation and percent error values of the assay method were all less than 14%.
    Matched MeSH terms: Chloramphenicol/blood
  2. Jia Woei Wong, Kah Hay Yuen, Kok Khiang Peh
    J Chromatogr B Biomed Sci Appl, 1998 Sep 25;716(1-2):387-91.
    PMID: 9824257
    A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of pentoxifylline in human plasma. Prior to analysis, pentoxifylline and the internal standard (chloramphenicol) were extracted from plasma sample using dichloromethane. The mobile phase comprised 0.02 M phosphoric acid adjusted to pH 4, methanol and tetrahydrofuran (55:45:1, v/v). Analysis was run at a flow-rate of 1.4 ml/min with the detector operated at a wavelength of 273 nm. The method was specific and sensitive with a detection limit of approximately 3.0 ng/ml at a signal to noise ratio of 3:1, while the limit of quantification was 12.5 ng/ml. Mean recovery value of the extraction procedure was about 99.9%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 10.0%. The calibration curve was linear over a concentration range of 12.5-400.0 ng/ml.
    Matched MeSH terms: Chloramphenicol/blood
  3. Ismail R, Teh LK, Choo EK
    Ann Trop Paediatr, 1998 Jun;18(2):123-8.
    PMID: 9924573
    Despite concerns about adverse effects, chloramphenicol (CMC) continues to be used in certain situations and, due to its low therapeutic index and variable pharmacokinetics, therapeutic drug monitoring (TDM) is often recommended. At our centre, CMC finds applications in typhoid and meningitis and TDM is routinely performed. Elsewhere in Malaysia, however, CMC is used without TDM. We therefore decided to evaluate our TDM for CMC in relation to its roles in CMC therapy in children, who constitute most of our patients. Our objective was also to develop strategies to improve our TDM for CMC use. Data were collected from 168 children given CMC for various indications and monitored by the TDM service. Plasma CMC was determined by HPLC and used to adjust doses to maintain concentrations within a range of 10-25 micrograms/ml. Outcomes measured included daily temperatures and haematological indices. Daily doses and plasma CMC varied greatly. Doses averaged 40.5 mg/kg for neonates and 75.5 for older children. Average peak concentrations were therapeutic in 60% and trough in 42%. Average duration of fever was 6.3 days and it was unaffected by plasma CMC. Typhoid was eradicated in 97% but nine children with other diagnoses died. Side-effects were confined to mild reversible haematological abnormalities which developed in 11% of children at plasma concentrations which tended to be high. We conclude that CMC remains useful in children with typhoid. Its use for other indications, however, should be reviewed. Routine TDM for CMC is probably not warranted, at least until a clearer role is defined by well designed prospective studies.
    Matched MeSH terms: Chloramphenicol/blood
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links