Displaying all 4 publications

Abstract:
Sort:
  1. Saaid M, Saad B, Ali AS, Saleh MI, Basheer C, Lee HK
    J Chromatogr A, 2009 Jul 3;1216(27):5165-70.
    PMID: 19481215 DOI: 10.1016/j.chroma.2009.04.091
    Hollow fibre liquid-phase microextraction with in situ derivatization using dansyl chloride has been successfully developed for the high-performance liquid chromatography-ultraviolet (HPLC-UV) determination of the biogenic amines (tryptamine, putrescine, cadaverine, histamine, tyramine, spermidine) in food samples. Parameters affecting the performance of the in situ derivatization process such as type of extraction solvent, temperature, extraction time, stirring speed and salt addition were studied and optimized. Under the optimized conditions (extraction solvent, dihexyl ether; acceptor phase, 0.1M HCl; extraction time, 30 min; extraction temperature, 26 degrees C; without addition of salt), enrichment factors varying from 47 to 456 were achieved. Good linearity of the analytes was obtained over a concentration range of 0.1-5 microg mL(-1) (with correlation coefficients of 0.9901-0.9974). The limits of detection and quantification based on a signal-to-noise ratio of 3-10, ranged from 0.0075 to 0.030 microg mL(-1) and 0.03 to 0.10 microg mL(-1), respectively. The relative standard deviations based on the peak areas for six replicate analysis of water spiked with 0.5 microg mL(-1) of each biogenic amine were lower than 7.5%. The method was successfully applied to shrimp sauce and tomato ketchup samples, offering an interesting alternative to liquid-liquid extraction and solid phase extraction for the analysis of biogenic amines in food samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/instrumentation
  2. Raharjo Y, Sanagi MM, Ibrahim WA, Naim AA, Aboul-Enein HY
    J Sep Sci, 2009 Feb;32(4):623-9.
    PMID: 19165835 DOI: 10.1002/jssc.200800566
    A liquid-phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 microL) of isooctane as the acceptor phase was introduced continually to fill-up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 microL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 microL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 microg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/instrumentation*
  3. Sundram K, Nor RM
    Methods Mol Biol, 2002;186:221-32.
    PMID: 12013770
    Matched MeSH terms: Chromatography, High Pressure Liquid/instrumentation
  4. Ruzilawati AB, Wahab MS, Imran A, Ismail Z, Gan SH
    J Pharm Biomed Anal, 2007 Apr 11;43(5):1831-5.
    PMID: 17240100
    In this study, the development and validation of a high-performance liquid chromatography (HPLC) assay for determination of repaglinide concentration in human plasma for pharmacokinetic studies is described. Plasma samples containing repaglinide and an internal standard, indomethacin were extracted with ethylacetate at pH 7.4. The recovery of repaglinide was 92%+/-55.31. Chromatographic separations were performed on Purospher STAR C-18 analytical column (4.8 mm x 150 mm; 5 microm particle size). The mobile phase composed of acetonitrile-ammonium formate (pH 2.7; 0.01 M) (60:40, v/v). The flow rate was 1 ml/min. The retention time for repaglinide and indomethacin were approximately 6.2 and 5.3 min, respectively. Calibration curves of repaglinide were linear in the concentration range of 20-200 ng/ml in plasma. The limits of detection and quantification were 10 ng/ml and 20 ng/ml, respectively. The inter-day precision was from 5.21 to 11.84% and the intra-day precision ranged from 3.90 to 6.67%. The inter-day accuracy ranged 89.95 to 105.75% and intra-day accuracy ranged from 92.37 to 104.66%. This method was applied to determine repaglinide concentration in human plasma samples for a pharmacokinetic study.
    Matched MeSH terms: Chromatography, High Pressure Liquid/instrumentation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links