Displaying all 5 publications

Abstract:
Sort:
  1. Ngeow YF, Chan L, Yasmin AH, Ong GS
    Med J Malaysia, 1994 Dec;49(4):427.
    PMID: 7674983
    Matched MeSH terms: Enteral Nutrition/instrumentation*
  2. Mahadeva S, Malik A, Hilmi I, Qua CS, Wong CH, Goh KL
    Nutr Clin Pract, 2008 Apr-May;23(2):176-81.
    PMID: 18390786 DOI: 10.1177/0884533608314535
    Transnasal endoscopic placement of nasoenteric tubes (NETs) has been demonstrated to be useful in the critical care setting, with limited data on its role in non-critically ill patients. The authors collected data on consecutive patients from a non-critical care setting undergoing transnasal endoscopic NET placement. All NETs were endoscopically placed using a standard over-the-guidewire technique, and positions were confirmed with fluoroscopy. Patients were monitored until the removal of NETs or death. Twenty-two patients (median age = 62.5 years, 36.4% female) were referred for postpyloric feeding, with main indications of persistent gastrocutaneous fistula (n = 6), gastroparesis or gastric outlet obstruction (n = 5), duodenal stenosis (n = 6), acute pancreatitis (n = 4), and gastroesophageal reflux after surgery (n = 1). Postpyloric placement of NET was achieved in 19 of 22 (86.3%) patients, with 36.8% tube positions in the jejunum, 47.4% in the distal duodenum, and 15.8% in the second part of the duodenum. NET placement was least successful in cases with duodenal stenosis. NETs remained in situ for a median of 24 days (range, 2-94), with tube dislodgement (n = 3) and clogging (n = 5) as the main complications. NET feeding resulted in complete healing of gastrocutaneous fistulae in 5 of 6 patients and provision of total enteral nutrition in 3 of 4 cases of acute pancreatitis and 9 of 11 cases of gastroparesis or proximal duodenal obstruction. Transnasal endoscopy has a role in the placement of NET in non-critically ill patients requiring postpyloric feeding. However, there are some limitations, particularly in cases with altered duodenal anatomy.
    Matched MeSH terms: Enteral Nutrition/instrumentation
  3. Chan L, Yasmin AH, Ngeow YF, Ong GS
    Med J Malaysia, 1994 Mar;49(1):62-7.
    PMID: 8057993
    A closed enteral delivery system consisting of a cardboard tetrapack containing the sterile ready-to-use liquid feed and an independent sterile administration set, has been devised. We found bacterial contamination within 24 hours in this system in patients on ventilatory support in intensive care. This emphasises the need for meticulous care in handling enteral feeding systems to prevent environmental contamination.
    Matched MeSH terms: Enteral Nutrition/instrumentation*
  4. Tan JH, Sivadurai G, Tan HCL, Tan YR, Jahit S, Hans Alexander M
    Surg Laparosc Endosc Percutan Tech, 2020 Apr;30(2):106-110.
    PMID: 31923160 DOI: 10.1097/SLE.0000000000000754
    BACKGROUND: Provision of enteral nutrition with jejunal feeding in upper gastrointestinal obstruction is highly recommended. Access to jejunum can be obtained surgically, percutaneously, or endoscopically. Our institution routinely and preferentially utilizes a silicone nasojejunal tube that is inserted past the obstruction endoscopically. We use a custom dual channel tube that allows feeding at the distal tip and another channel 40 cm from the tip that enables decompression proximally. This is a report of our experience with this custom nasojejunal tube.

    METHODS: This is a prospective observational study of 201 patients who underwent endoscopic nasojejunal wire-guided feeding tube insertions for obstruction of either the esophagus or the stomach including both benign and malignant pathologies between January 2015 to June 2018 in Hospital Sungai Buloh and Hospital Sultanah Aminah, Malaysia. The indications for tube insertion, insertion technique, and tube-related problems were described.

    RESULTS: The nasojejunal tube was used to establish enteral feeding in patients with obstructing tumors of the distal esophagus in 65 patients (32.3%) and gastric outlet obstruction in 72 patients (35.8%). There were 54 patients (26.9%) who required reinsertion. The most common reason for reinsertion was unintentional dislodgement, where 32 patients (15.9%) followed by tube blockage 20 patients (10.0%). Using our method of advancement under direct vision, we had only 2 cases of malposition due to severely deformed anatomy. We had no incidence of aspiration in this group of patients and overall, the patients tolerated the tube well.

    CONCLUSIONS: The novel nasojejunal feeding tube with gastric decompression function is a safe and effective method of delivery of enteral nutrition in patients with upper gastrointestinal obstruction. These tubes if inserted properly are well tolerated with almost no risk of malposition and are tolerated well even for prolonged periods of time until definitive surgery could be performed.

    Matched MeSH terms: Enteral Nutrition/instrumentation*
  5. Siow SL, Mahendran HA, Wong CM, Milaksh NK, Nyunt M
    BMC Surg, 2017 Mar 20;17(1):25.
    PMID: 28320382 DOI: 10.1186/s12893-017-0221-2
    BACKGROUND: In recent years, staging laparoscopy has gained acceptance as part of the assessment of resectability of upper gastrointestinal (UGI) malignancies. Not infrequently, we encounter tumours that are either locally advanced; requiring neoadjuvant therapy or occult peritoneal disease that requires palliation. In all these cases, the establishment of enteral feeding during staging laparoscopy is important for patients' nutrition. This review describes our technique of performing laparoscopic feeding jejunostomy and the clinical outcomes.

    METHODS: The medical records of all patients who underwent laparoscopic feeding jejunostomy following staging laparoscopy for UGI malignancies between January 2010 and July 2015 were retrospectively reviewed. The data included patient demographics, operative technique and clinical outcomes.

    RESULTS: Fifteen patients (11 males) had feeding jejunostomy done when staging laparoscopy showed unresectable UGI maligancy. Eight (53.3%) had gastric carcinoma, four (26.7%) had oesophageal carcinoma and three (20%) had cardio-oesophageal junction carcinoma. The mean age was 63.3 ± 7.3 years. Mean operative time was 66.0 ± 7.4 min. Mean postoperative stay was 5.6 ± 2.2 days. Laparoscopic feeding jejunostomy was performed without intra-operative complications. There were no major complications requiring reoperation but four patients had excoriation at the T-tube site and three patients had tube dislodgement which required bedside replacement of the feeding tube. The mean duration of feeding tube was 127.3 ± 99.6 days.

    CONCLUSIONS: Laparoscopic feeding jejunostomy is an important adjunct to staging laparoscopy that can be performed safely with low morbidity. Meticulous attention to surgical techniques is the cornerstone of success.

    Matched MeSH terms: Enteral Nutrition/instrumentation*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links