Displaying all 5 publications

Abstract:
Sort:
  1. Ismail AI, Abdul Majid AH, Zakaria MN, Abdullah NAC, Hamzah S, Mukari SZS
    Int J Pediatr Otorhinolaryngol, 2018 Jun;109:78-84.
    PMID: 29728190 DOI: 10.1016/j.ijporl.2018.03.030
    OBJECTIVE: The current study aims to examine the effects of human resource (measured with the perception of health workers' perception towards UNHS), screening equipment, program layout and screening techniques on healthcare practitioners' awareness (measured with knowledge) of universal newborn hearing screening (UNHS) in Malaysian non-public hospitals.

    METHODS: Via cross sectional approach, the current study collected data using a validated questionnaire to obtain information on the awareness of UNHS program among the health practitioners and to test the formulated hypotheses. 51, representing 81% response rate, out of 63 questionnaires distributed to the health professionals were returned and usable for statistical analysis. The survey instruments involving healthcare practitioners' awareness, human resource, program layout, screening instrument, and screening techniques instruments were adapted and scaled with 7-point Likert scale ranging from 1 (little) to 7 (many). Partial Least Squares (PLS) algorithm and bootstrapping techniques were employed to test the hypotheses of the study.

    RESULTS: With the result involving beta values, t-values and p-values (i.e. β=0.478, t=1.904, p<0.10; β=0.809, t=3.921, p<0.01; β= -0.436, t=1.870, p<0.10), human resource, measured with training, functional equipment and program layout, are held to be significant predictors of enhanced knowledge of health practitioners. Likewise, program layout, human resource, screening technique and screening instrument explain 71% variance in health practitioners' awareness. Health practitioners' awareness is explained by program layout, human resource, and screening instrument with effect size (f2) of 0.065, 0.621, and 0.211 respectively, indicating that program layout, human resource, and screening instrument have small, large and medium effect size on health practitioners' awareness respectively. However, screening technique has zero effect on health practitioners' awareness, indicating the reason why T-statistics is not significant.

    CONCLUSION: Having started the UNHS program in 2003, non-public hospitals have more experienced and well-trained employees dealing with the screening tools and instrument, and the program layout is well structured in the hospitals. Yet, the issue of homogeneity exists. Non-public hospitals charge for the service they render, and, in turn, they would ensure quality service, given that they are profit-driven and/or profit-making establishments, and that they would have no option other than provision of value-added and innovative services. The employees in the non-public hospitals have less screening to carry out, given the low number of babies delivered in the private hospitals. In addition, non-significant relationship between screening techniques and healthcare practitioners' awareness of UNHS program is connected with the fact that the techniques that are practiced among public and non-public hospital are similar and standardized. Limitations and suggestions were discussed.

    Matched MeSH terms: Neonatal Screening/organization & administration*
  2. Mukari SZ, Tan KY, Abdullah A
    Int J Pediatr Otorhinolaryngol, 2006 May;70(5):843-51.
    PMID: 16246430
    This paper reports the performance of a newly implemented hospital-based universal newborn hearing screening programme and the challenges to the effective implementation.
    Matched MeSH terms: Neonatal Screening/organization & administration*
  3. Chua BS, Song LH, Chang CT, Lim XJ, Nachiappan J
    J Paediatr Child Health, 2021 01;57(1):12-14.
    PMID: 33078471 DOI: 10.1111/jpc.15226
    The coronavirus disease 2019 (COVID-19) cases was on an increasing trend, including in Malaysia. The Malaysian Ministry of Health had implemented a range of measures, such as the use of masks and social distancing, to reduce the risk of transmission. Traditionally, newborns are evaluated for neonatal jaundice using visual assessment, a capillary heel prick and serum bilirubin (SB) sampling in primary health-care clinics. This approach requires the physical presence of both parents and their newborns in the primary health-care clinics, causing crowding and increasing the risk of COVID-19 infections. To alleviate crowding, we implemented the transcutaneous bilirubin drive-through (DT) service, which is an established, non-invasive, painless and rapid method to determine the bilirubin levels. Throughout the screening, both parents and baby will be confined to their car. A total of 1842 babies were screened in our DT setting from April to July 2020. Of the total babies, 298 (16.1%) required venesection for SB measurement and 85 required admission for phototherapy. None with severe jaundice were missed since the implementation of this service. The average test duration per neonate was less than 5 min, while conventional venous bilirubin laboratory testing required an average of 1.5 h per neonate. The cost of the SB laboratory test and consumables was approximately USD 5 per test, with an estimated cost savings of USD 7720. DT screening may be introduced in health-care settings to reduce crowding and eliminate the need of painful blood sampling in newborns.
    Matched MeSH terms: Neonatal Screening/organization & administration
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links