Displaying all 4 publications

Abstract:
Sort:
  1. Goh YH
    Perit Dial Int, 2008 11 5;28(6):626-31.
    PMID: 18981393
    BACKGROUND: Omental wrap is a common cause of catheter obstruction. Current laparoscopic techniques for correcting obstruction include omentopexy and omentectomy. This study evaluates the efficacy of a new laparoscopic technique for revision of obstructed peritoneal dialysis catheters.

    METHODS: Between November 2005 and November 2006, the technique was applied in 18 patients (6 female, 12 male; median age 50 years, range 16 - 73 years) on continuous ambulatory peritoneal dialysis with catheter malfunction secondary to omental wrap. Pneumoperitoneum was induced under general anesthesia. Three ports were inserted. The catheter was released from the omentum and repositioned in the pelvis. The omentum was then folded onto itself in a cephalad direction using silk sutures. This shortened the omentum. The risk of catheter migration was minimized with a polypropylene sling passed through the abdominal wall and around the catheter, then knotted subcutaneously. The sling allowed catheter removal without a new laparoscopy. The outcomes were prospectively evaluated.

    RESULTS: Median operating time was 90 minutes (range 35 - 160 minutes). Adhesiolysis was performed in 4 patients: 1 patient had port-site leakage of dialysate, which settled with abdominal rest; 1 patient had bleeding during adhesiolysis and laparoscopic hemostasis was successful; 1 patient had recurrent catheter obstruction 2 weeks post-operatively and was converted to hemodialysis; and 1 patient had recurrent malfunction secondary to small bowel wrap after 5.5 months; re-salvage was successful. The success rate of the first salvage procedure was 89%(16/18). The catheters were still functioning after a mean follow-up of 16.5 +/- 6.3 months (range 0.5 - 24 months). The 1-year catheter survival rate was 83.3%.

    CONCLUSIONS: Omental folding is a safe and effective technique for salvaging peritoneal dialysis catheters.

    Matched MeSH terms: Peritoneal Dialysis, Continuous Ambulatory/instrumentation*
  2. Ong LM, Lim TO, Hooi LS, Morad Z, Tan PC, Wong HS, et al.
    Perit Dial Int, 2003 Dec;23 Suppl 2:S139-43.
    PMID: 17986534
    OBJECTIVE: In the present study, we undertook to establish therapeutic equivalence with respect to peritonitis and technique failure between the Carex disconnect system (B. Braun Carex, Mirandola, Italy) and the standard Ultra system (Baxter Healthcare, Tokyo, Japan) in patients on continuous ambulatory peritoneal dialysis (CAPD).

    DESIGN: This multicenter, parallel group, randomized controlled trial involved 363 prevalent CAPD patients from 8 centers. The primary endpoint was peritonitis rate; secondary endpoints were technique failure and technical problems encountered. The duration of the evaluation was 1 year.

    RESULTS: The risk of peritonitis on Carex varied between the centers. We found a significant treatment-center interaction effect (likelihood ratio test: p = 0.03). The incidence rate ratio (IRR) of peritonitis on Carex as compared with Ultra ranged from 0.4 to 7.2. In two centers, Carex was inferior to Ultra with regard to peritonitis; but, in five centers, the results were inconclusive. Equivalence was not demonstrated in any center. The overall rate of peritonitis in the Carex group was twice that in the Ultra group [IRR: 2.18; 95% confidence interval (CI): 1.51 to 3.14]. Technique failure and technical problems were more common with the Carex system. Technique failure rate at 1 year was 44% in the Carex group and 22% in the Ultra group.

    CONCLUSIONS: Equivalence between the Carex disconnect system and the Ultra disconnect system could not be demonstrated. The risk of peritonitis on Carex varied significantly between centers.

    Matched MeSH terms: Peritoneal Dialysis, Continuous Ambulatory/instrumentation*
  3. Wong CM, Ng KP, Keng TC, Lim SK, Tan SY
    Perit Dial Int, 2011 3 24;31(2):194-6.
    PMID: 21427247 DOI: 10.3747/pdi.2009.00237
    Matched MeSH terms: Peritoneal Dialysis, Continuous Ambulatory/instrumentation*
  4. Liu WJ, Hooi LS
    Perit Dial Int, 2010 03 12;30(5):509-12.
    PMID: 20228175 DOI: 10.3747/pdi.2009.00083
    OBJECTIVE: To analyze the complications after Tenckhoff catheter insertion among patients with renal failure needing dialysis. ♢

    PATIENTS AND METHODS: The open, paramedian approach is the commonest technique to insert the 62-cm coiled double-cuffed Tenckhoff peritoneal catheter. All patients with catheters inserted between January 2004 and November 2007 were retrospectively analyzed for demographics and followed for up to 1 month for complications. We excluded patients whose catheters had been anchored to the bladder wall and who underwent concurrent omentectomy or readjustment without removal of a malfunctioning catheter (n = 7). Intravenous cloxacillin was the standard preoperative antibiotic prophylaxis. ♢

    RESULTS: Over the 4-year study period, 384 catheters were inserted under local anesthetic into 319 patients [201 women (62.8%); mean age: 49.4 ± 16.7 years (range: 13 - 89 years); 167 (52.2%) with diabetes; 303 (95%) with end-stage renal disease] by 22 different operators. All Tenckhoff catheters were inserted by the general surgical (n = 223) or urology (n = 161) team. There were 29 cases (7.6%) of catheter migration, 22 (5.7%) of catheter obstruction without migration, 24 (6.3%) of exit-site infection, 12 (3.1%) of leak from the main incision, 14 (3.6%) of culture-proven wound infection, 11 (2.9%) post-insertion peritonitis, and 1 (0.3%) hemoperitoneum. No deaths were attributed to surgical mishap. ♢

    CONCLUSIONS: The most common complication was catheter migration. The paramedian insertion technique was safe, with low complication rates.

    Matched MeSH terms: Peritoneal Dialysis, Continuous Ambulatory/instrumentation