When the definition of calm in atmospheric diffusion analyses is changed from 0.5 m s-1 to 0.1 m s-1, actual and more accurate low wind speeds and wind directions can be used to calculate the average air concentrations due to continuous releases of radionuclides at 10-m stack height more realistically and accurately. However, this modified calm condition has little affect on the calculated adult thyroid exposure for a postulated accident.