Affiliations 

  • 1 Departments of Medical Microbiology & Immunology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Kuala Lumpur
Malays J Pathol, 1994 Dec;16(2):157-60.
PMID: 9053565

Abstract

Variable parameters in chemiluminescence assay, one of the methods used to assess the functional capacity of neutrophils, were evaluated for suitable adaptation locally. The use of pooled normal human serum as compared to single normal human serum in opsonizing particles for phagocytosis was found to exhibit lower chemiluminescence activity (reduction range of 30%-50%). A similar degree of depression was observed when the particles were opsonized using normal human serum in comparison to that using autologous serum. Different intensity of chemiluminescence was also noted when the opsonized particle used was the Oxford strain of Staphylococcus aureus (NCTC 6571) in contrast to a strain of Staphylococcus aureus isolated from a patient. The results obtained warrant clinicians to deliver appropriate samples as best they can when the chemiluminescence assay is requested.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.