Affiliations 

  • 1 Universiti Putra Malaysia
  • 2 Kyoto University
  • 3 Norwich University Park
MyJurnal

Abstract

The aim of this study was to assess the most probable number-polymerase chain reaction (MPNPCR) technique for detection of Listeria monocytogenes in salad vegetables in comparison with reference EN ISO 11290-2 and Food Drug Administration Bacteriological Analytical Manual method using artificial and naturally contaminated samples. Based on recovery of L. monocytogenes from artificially contaminated samples, MPN-PCR showed a moderate correlation (R=0.67) between spiking concentration and microbial levels which was better than the FDA-BAM method (R=0.642) and ISO 11290-2:1998 method (R=0.655). With naturally contaminated samples, it was found that L. monocytogenes was detected in 25% of the vegetable samples using MPN-PCR; 15% of the samples by the FDA-BAM method and 8% of samples using ISO 11290-2:1998 method. Overall, MPN-PCR was found to be a rapid and reliable method that could facilitate the enumeration of L. monocytogenes in vegetables.