Displaying all 3 publications

Abstract:
Sort:
  1. Supramaniam TT, Udin MY, Musarudin M
    World J Nucl Med, 2025 Mar;24(1):47-56.
    PMID: 39959142 DOI: 10.1055/s-0044-1795102
    Objective  In nuclear medicine, quality control (QC) activities adhere to international standards, yet their complexity can pose challenges. Gamma camera manufacturers have introduced integrated QC software, offering instantaneous results. However, the agreement of these automated processes with established protocols remains uncertain. This study aims to clarify this uncertainty by comparatively analyzing uniformity from various software solutions for a dual-head gamma camera. Methods  The study utilized integrated QC analysis software and three free QC analysis tools (IAEA-NMQC Toolkit, NM Toolkit, and Fiji) for uniformity analyses. Following the National Electrical Manufacturers Association standards, NEMA Standards Publication NU 1-2018, the intrinsic uniformity test was performed on a GE Discovery NM/CT 670 Pro system. Ten uniformity QC images underwent analysis with both integrated QC software and alternative software. Data agreements were tested using the Blant-Altman regression-based analysis. Results  Significant differences were observed in integral and differential uniformities ( p  
  2. Tagiling N, Ibrahim IL, Lee YY, Udin MY, Mohamad Kamarulzaman MD, Phoa PKA, et al.
    J Gastroenterol Hepatol, 2024 Aug;39(8):1517-1527.
    PMID: 38705971 DOI: 10.1111/jgh.16585
    BACKGROUND AND AIM: Measurements of gastric emptying and accommodation for alternative test-meal protocol during gastric emptying scintigraphy (GES), such as high-calorie nutrient drinks, are not fully established. We aimed to compare the effects of standardized egg-white meal (EWM) versus high-calorie nutrient drink (Vital®; Abbott Laboratories) on global GES parameters and intragastric meal distribution at immediate scan (IMD0h).

    METHODS: Of 84 screened participants, 60 asymptomatic healthy Asian population (38 females; 24.0 ± 1.5 years; 23.8 ± 2.6 kg/m2) were recruited in this 2 × 2 (AB/BA) crossover trial. Participants were randomized to a 4-h GES with 99mTc-radiolabeled EWM (~255.8 kcal), followed by a 200 mL Vital® (300 kcal), or vice versa, separated by a 2-week washout period. Global meal retention (GMR), power-exponential model emptying parameters (half-emptying [T1/2], lag phases [Tlag2%, Tlag5%, Tlag10%]), and IMD0h were determined and compared.

    RESULTS: GMRs for both test meals were within the international standard references for solid GES. Compared to EWM, Vital® exhibited significantly lower GMRs (faster emptying) from 0.5 to 3 h (all P 

  3. Tagiling N, Lee YY, Mohd Rohani MF, Udin MY, Abdul Aziz A, Muhamad SN, et al.
    PMID: 39835631 DOI: 10.1111/nmo.15006
    BACKGROUND: Gastric accommodation (GA) testing is gaining clinical recognition as novel and minimally invasive modalities emerge. We investigated the feasibility of hybrid nuclear imaging volumetry (SPECT/CT) and combined high-resolution manometry-nutrient drink test (HRM-NDT) to assess GA.

    METHODS: In this non-randomized pilot study, [99mTc]NaTcO4 gastric SPECT/CT (250 mL protocol) and proximal gastric HRM-NDT (~60 mL/min protocol) were performed separately within 30 days using Ensure Gold test meal (1.05 kcal/mL; Abbott). GA parameters were measured, and their preliminary associations were examined using Spearman's ρ and Hoeffding's D correlation tests. Data were presented as median ± normalized median absolute deviation.

    KEY RESULTS: Twenty healthy, asymptomatic individuals (11 females; 23.5 ± 2.2 years, 23.7 ± 2.2 kg/m2) completed both procedures without serious adverse events and interrupted sessions. The accommodation volume and postprandial-to-fasting volume ratio from SPECT/CT were 325.8 ± 28.5 mL and 5.31 ± 1.28, respectively. During HRM-NDT, the nadir-intragastric pressure (IGP) was -6.6 ± 3.6 mmHg at an ingested volume of 360.0 ± 177.9 mL, and the area-under-curve of IGP was -1566.0 ± 1596.8 mmHg·mL. The maximum tolerated volume for reaching satiety/maximum discomfort was 450.0 ± 177.9 mL, and the area-under-curve of satiation score was 900.0 ± 266.9 satiation-unit·mL. The area-under-curve of IGP showed significant associations with maximum tolerated volume (ρ: -0.702; D: 0.234) and the area-under-curve of satiation score (D: 0.119): all p 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links