METHODS: CBCT was used to assess 200 joints in 100 subjects (mean age, 30.5 years). i-CAT CBCT software and The Mimics 16.0 software were employed to measure the volume, metrical size, position of each condyle sample and the thickness of the roof of the glenoid fossa (RGF).
RESULTS: No significant gender differences were noted in thickness of the RGF and condylar length; however condylar volume, width, height and the joint spaces were significantly greater among males. With regards to comparison of both TMJs, the means of condylar volume, width and length of the right TMJ were significantly higher, while the means of the left condylar height and thickness of RGF were higher. When comparing the condylar measurements and the thickness of RGF between the two ethnic groups, we found no significant difference for all measurements with exception of condylar height, which is higher among Chinese.
CONCLUSION: The similarity in measurements for Malays and Chinese may be due to their common origin. This information can be clinically useful in establishing the diagnostic criteria for condylar volume, metrical size, and position in the Malaysian East Asians population.
MATERIAL AND METHODS: Sandblasted and cleansed planar titanium specimens with a size of 5 × 5 × 1 mm were coated on one side with 0.25 vol% eicosapentaenoic acid (EPA). The other side of the specimens was kept highly polished (the control side). These specimens were inserted in rabbit mandibles. Twelve rabbits were randomly assigned into three study groups (n = 4). The rabbits were sacrificed at 4, 8, and 12 weeks. The harvested specimens with the implants were assessed for new bone formation on both sides of the implant using CBCT, conventional radiographs, and the biaxial pullout test. The results were statistically analyzed by a nonparametric Kruskal-Wallis test and Friedman's test as multiple comparisons and by Brunner-Langer nonparametric mixed model approach (R Software).
RESULTS: A significant osteoconductive bone formation was found on the EPA-coated Ti implant surface (P < 0.05) at 8 weeks when compared to the polished surface (control). Biaxial pullout test results showed a significant difference (P < 0.05) after 8 and 12 weeks with a maximum force of 243.8 N, compared to 143.25 N after 4 week.
CONCLUSION: EPA implant coating promoted osteoconduction on the Ti implant surfaces, enhancing the anchorage of the implant to the surrounding bone in white New Zealand rabbits.
METHODS: Fifty digital models were scanned from the same plaster models. Arch and tooth size measurements were made by 2 operators, twice. Calibration was done on 10 sets of models and checked using the Pearson correlation coefficient. Data were analyzed by error variances, repeatability coefficient, repeated-measures analysis of variance, and Bland-Altman plots.
RESULTS: Error variances ranged between 0.001 and 0.044 mm for the digital caliper method, and between 0.002 and 0.054 mm for the 3D software method. Repeated-measures analysis of variance showed small but statistically significant differences (P <0.05) between the repeated measurements in the arch and buccolingual planes (0.011 and 0.008 mm, respectively). There were no statistically significant differences between methods and between operators. Bland-Altman plots showed that the mean biases were close to zero, and the 95% limits of agreement were within ±0.50 mm. Repeatability coefficients for all measurements were similar.
CONCLUSIONS: Measurements made on models scanned by the 3D structured-light scanner were in good agreement with those made on conventional plaster models and were, therefore, clinically acceptable.
METHODOLOGY: Jaw sections containing 67 teeth (86 roots) were collected from unclaimed bodies due for cremation. Imaging was carried out to detect AP by digital PR with a central view (DP group), digital PR combining central with 10˚ mesially and distally angled (parallax) views (DPS group) and CBCT scans. All specimens underwent histopathological examination to confirm the diagnosis of AP. Sensitivity, specificity and predictive values of PR and CBCT were analysed using rater mean (n = 5). Receiver-operating characteristic (ROC) analysis was carried out.
RESULTS: Sensitivity was 0.27, 0.38 and 0.89 for DP, DPS and CBCT scans, respectively. CBCT had specificity and positive predictive value of 1.0 whilst DP and DPS had specificity and positive predictive value of 0.99. The negative predictive value was 0.39, 0.44 and 0.81 for DP, DPS and CBCT scans, respectively. Area under the curve (AUC) for the various imaging methods was 0.629 (DP), 0.688 (DPS), and 0.943 (CBCT).
CONCLUSIONS: All imaging techniques had similar specificity and positive predictive values. Additional parallax views increased the diagnostic accuracy of PR. CBCT had significantly higher diagnostic accuracy in detecting AP compared to PR, using human histopathological findings as a reference standard.