OBJECTIVE: The primary objective of this study was to examine the validity and reliability of the Borg CR-10 scale to monitor the perceived exertion of office exercise training.
METHODS: The study involved 105 staff members employed in a government office with an age range from 25 to 50 years. The Borg CR-10 scale was self-administered two times, with an interval of two weeks in order to evaluate the accuracy of the original findings with a retest. Face validity and content validity were also examined.
RESULTS: Reliability was found to be high for the Borg CR-10 scale (0.898). Additionally a high correlation between the Borg CR-10 scale and Visual Analog Scale (VAS) was identified (rs = 0.754, P
OBJECTIVE: To investigate the effect of hand position and lower limb length measurement method on LQ-YBT scores and their interpretation.
DESIGN: Cross-sectional study.
SETTING: National Sports Institute of Malaysia.
PATIENTS OR OTHER PARTICIPANTS: A total of 46 volunteers, consisting of 23 men (age = 25.7 ± 4.6 years, height = 1.70 ± 0.05 m, mass = 69.3 ± 9.2 kg) and 23 women (age = 23.5 ± 2.5 years, height = 1.59 ± 0.07 m, mass = 55.7 ± 10.6 kg).
INTERVENTION(S): Participants performed the LQ-YBT with hands on hips and hands free to move on both lower limbs.
MAIN OUTCOME MEASURE(S): In a single-legged stance, participants reached with the contralateral limb in each of the anterior, posteromedial, and posterolateral directions 3 times. Maximal reach distances in each direction were normalized to lower limb length measured from the anterior-superior iliac spine to the lateral and medial malleoli. Composite scores (average of the 3 normalized reach distances) and anterior-reach differences (in raw units) were extracted and used to identify participants at risk for injury (ie, anterior-reach difference ≥4 cm or composite score ≤94%). Data were analyzed using paired t tests, Fisher exact tests, and magnitude-based inferences (effect size [ES], ±90% confidence limits [CLs]).
RESULTS: Differences between hand positions in normalized anterior-reach distances were trivial (t91 = -2.075, P = .041; ES = 0.12, 90% CL = ±0.10). In contrast, reach distances were greater when the hands moved freely for the normalized posteromedial (t91 = -6.404, P < .001; ES = 0.42, 90% CL = ±0.11), posterolateral (t91 = -6.052, P < .001; ES = 0.58, 90% CL = ±0.16), and composite (t91 = -7.296, P < .001; ES = 0.47, 90% CL = ±0.11) scores. A similar proportion of the cohort was classified as at risk with the hands on the hips (35% [n = 16]) and the hands free to move (43% [n = 20]; P = .52). However, the participants classified as at risk with the hands on the hips were not all categorized as at risk with the hands free to move and vice versa. The lower limb length measurement method exerted trivial effects on LQ-YBT outcomes.
CONCLUSIONS: Hand position exerted nontrivial effects on LQ-YBT outcomes and interpretation, whereas the lower limb length measurement method had trivial effects.
OBJECTIVE: The purpose of this study was to evaluate the system's performance during treadmill tests to maximum exertion in a subset of patients within the Micra Transcatheter Pacing Study.
METHODS: Patients underwent treadmill testing at 3 or 6 months postimplant with algorithm programming at physician discretion. Normalized sensor rate (SenR) relative to the programmed upper sensor rate was modeled as a function of normalized workload in metabolic equivalents (METS) relative to maximum METS achieved during the test. A normalized METS and SenR were determined at the end of each 1-minute treadmill stage. The proportionality of SenR to workload was evaluated by comparing the slope from this relationship to the prospectively defined tolerance margin (0.65-1.35).
RESULTS: A total of 69 treadmill tests were attempted by 42 patients at 3 and 6 months postimplant. Thirty tests from 20 patients who completed ≥4 stages with an average slope of 0.86 (90% confidence interval 0.77-0.96) confirmed proportionality to workload. On an individual test basis, 25 of 30 point estimates (83.3%) had a normalized slope within the defined tolerance range (range 0.46-1.08).
CONCLUSION: Accelerometer-based rate adaptive pacing was proportional to workload, thus confirming rate adaptive pacing commensurate to workload is achievable with an entirely intracardiac pacing system.