Displaying publications 1 - 20 of 92 in total

Abstract:
Sort:
  1. Saadatnia G, Mohamed Z, Ghaffarifar F, Osman E, Moghadam ZK, Noordin R
    APMIS, 2012 Jan;120(1):47-55.
    PMID: 22151308 DOI: 10.1111/j.1600-0463.2011.02810.x
    Infection with Toxoplasma gondii is widespread and important in humans, especially pregnant women and immunosuppressed patients. A panel of tests is usually required for diagnosis toxoplasmosis. Excretory secretory antigen (ESA) is highly immunogenic, and thus it is a good candidate for investigation into new infection markers. ESA was prepared from tachyzoites of RH strain of T. gondii by mice intraperitoneal infection. Sera were obtained from several categories of individuals who differed in their status of anti-Toxoplasma IgM, IgG and IgG avidity antibodies. The ESA was subjected to SDS-PAGE, two-dimensional gel electrophoresis and Western blot analysis. Antigenic bands of approximate molecular weights of 12, 20 and 30 kDa, when probed with anti-human IgM-HRP and IgA-HRP, showed good potential as infection markers. The highest sensitivity of the bands was 98.7% with combination of IgM and IgA blots with sera of patients with anti-Toxoplasma IgM+ IgG+. The specificities were 84% and 70% with sera from other infections and healthy controls in IgM blots and IgA blots respectively. By mass spectrometry, the 12 kDa protein was identified as thioredoxin. The two top proteins identified for 20 kDa molecule were microneme protein 10 and dense granule protein 7; whereas that for 30 kDa were phosphoglycerate mutase 1 and phosphoglycerate mutase.
    Matched MeSH terms: Immunoglobulin M/blood
  2. Choo KE, Davis TM, Ismail A, Tuan Ibrahim TA, Ghazali WN
    Acta Trop, 1999 Mar 15;72(2):175-83.
    PMID: 10206117
    The Typhidot test, which detects IgM and IgG antibodies to a Salmonella typhi-specific outer membrane protein, is as sensitive as, and more specific than, the Widal test in the diagnosis of enteric fever in Malaysian children. It is easier and quicker to perform. In order to increase diagnostic accuracy in an area of high endemicity, the Typhidot-M test has been developed in which IgG is first removed. This theoretically allows improved detection of IgM, and thus would differentiate new from recent infections. We evaluated both tests in 134 unselected febrile children admitted to the General Hospital Kota Bharu, Malaysia. The children were divided into two groups: (i) those who were blood and/or stool culture positive for S. typhi and/or who had clinical features strongly suggestive of enteric fever (n = 62); and (ii) those who were both culture-negative and had clinical evidence of another diagnosis (n = 72). The sensitivity and specificity of the Typhidot and Typhidot-M tests were identical at 90.3 and 93.1%, respectively. Both tests had comparable sensitivity but greater specificity than those of the Widal test (91.9 and 80.6%, respectively). When used together, a positive result for Typhidot and/or Typhidot-M was more specific than either test alone (95.2%) but specificity was lower (87.5%). We conclude that the Typhidot and Typhidot-M tests have comparatively high diagnostic accuracy, suggesting that IgM can be detected in children who may have a predominant IgG response to S. typhi. Using these tests in combination increases the negative predictive value but at the cost of a lower positive predictive value.
    Matched MeSH terms: Immunoglobulin M/blood
  3. Wong WR, Krupin O, Sekaran SD, Mahamd Adikan FR, Berini P
    Anal Chem, 2014 Feb 4;86(3):1735-43.
    PMID: 24410440 DOI: 10.1021/ac403539k
    We present a compact, cost-effective, label-free, real-time biosensor based on long-range surface plasmon polariton (LRSPP) gold (Au) waveguides for the detection of dengue-specific immunoglobulin M (IgM) antibody, and we demonstrate detection in actual patient blood plasma samples. Two surface functionalization approaches are proposed and demonstrated: a dengue virus serotype 2 (DENV-2) functionalized surface to capture dengue-specific IgM antibody in blood plasma and the reverse, a blood plasma functionalized surface to capture DENV-2. The results obtained via these two surface functionalization approaches are comparable to, or of greater quality, than those collected by conventional IgM antibody capture enzyme linked immunosorbent assay (MAC-ELISA). Our second functionalization approach was found to minimize nonspecific binding, thus improving the sensitivity and accuracy of the test. We also demonstrate reuse of the biosensors by regenerating the sensing surface down to the virus (or antibody) level or down to the bare Au.
    Matched MeSH terms: Immunoglobulin M/blood
  4. Tan XT, Amran F, Chee Cheong K, Ahmad N
    BMC Infect Dis, 2014;14:563.
    PMID: 25338815 DOI: 10.1186/s12879-014-0563-7
    Leptospirosis is a zoonotic disease caused by Leptospira species and is distributed globally. Microscopic agglutination test (MAT) is the serological 'gold standard' for diagnosis of leptospirosis but it is time-consuming and labour-intensive. An alternative serological method that is rapid, sensitive and specific is important for early treatment to reduce morbidity and mortality. The use of local Leptospira isolation may improve the sensitivity and specificity of the test because it may varies from one geographical region to another region. The objective of this study was to determine the sensitivity, specificity and cut-off points for an in-house Immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) using a locally isolated Leptospiral strain IMR/175 as the antigen for the detection of anti-Leptospiral IgM.
    Matched MeSH terms: Immunoglobulin M/blood
  5. Amerizadeh A, Khoo BY, Teh AY, Golkar M, Abdul Karim IZ, Osman S, et al.
    BMC Infect Dis, 2013;13:287.
    PMID: 23800344 DOI: 10.1186/1471-2334-13-287
    Toxoplasma gondii is an obligate intracellular zoonotic parasite of the phylum Apicomplexa which infects a wide range of warm-blooded animals, including humans. In this study in-vivo induced antigens of this parasite was investigated using in-vivo induced antigen technology (IVIAT) and pooled sera from patients with serological evidence of acute infection.
    Matched MeSH terms: Immunoglobulin M/blood
  6. Hajissa K, Zakaria R, Suppian R, Mohamed Z
    BMC Infect Dis, 2017 12 29;17(1):807.
    PMID: 29284420 DOI: 10.1186/s12879-017-2920-9
    BACKGROUND: The inefficiency of the current tachyzoite antigen-based serological assays for the serodiagnosis of Toxoplasma gondii infection mandates the need for acquirement of reliable and standard diagnostic reagents. Recently, epitope-based antigens have emerged as an alternative diagnostic marker for the achievement of highly sensitive and specific capture antigens. In this study, the diagnostic utility of a recombinant multiepitope antigen (USM.TOXO1) for the serodiagnosis of human toxoplasmosis was evaluated.

    METHODS: An indirect enzyme-linked immunosorbent assay (ELISA) was developed to evaluate the usefulness of USM.TOXO1 antigen for the detection of IgG antibodies against Toxoplasma gondii in human sera. Whereas the reactivity of the developed antigen against IgM antibody was evaluated by western blot and Dot enzyme immunoassay (dot-EIA) analysis.

    RESULTS: The diagnostic performance of the new antigens in IgG ELISA was achieved at the maximum values of 85.43% and 81.25% for diagnostic sensitivity and specificity respectively. The USM.TOXO1 was also proven to be reactive with anti- T. gondii IgM antibody.

    CONCLUSIONS: This finding makes the USM.TOXO1 antigen an attractive candidate for improving the toxoplasmosis serodiagnosis and demonstrates that multiepitope antigens could be a potential and promising diagnostic marker for the development of high sensitive and accurate assays.

    Matched MeSH terms: Immunoglobulin M/blood
  7. Chong ZL, Sekaran SD, Soe HJ, Peramalah D, Rampal S, Ng CW
    BMC Infect Dis, 2020 Mar 12;20(1):210.
    PMID: 32164538 DOI: 10.1186/s12879-020-4911-5
    BACKGROUND: Dengue is an emerging infectious disease that infects up to 390 million people yearly. The growing demand of dengue diagnostics especially in low-resource settings gave rise to many rapid diagnostic tests (RDT). This study evaluated the accuracy and utility of ViroTrack Dengue Acute - a new biosensors-based dengue NS1 RDT, SD Bioline Dengue Duo NS1/IgM/IgG combo - a commercially available RDT, and SD Dengue NS1 Ag enzyme-linked immunosorbent assay (ELISA), for the diagnosis of acute dengue infection.

    METHODS: This prospective cross-sectional study consecutively recruited 494 patients with suspected dengue from a health clinic in Malaysia. Both RDTs were performed onsite. The evaluated ELISA and reference tests were performed in a virology laboratory. The reference tests comprised of a reverse transcription-polymerase chain reaction and three ELISAs for the detection of dengue NS1 antigen, IgM and IgG antibodies, respectively. The diagnostic performance of evaluated tests was computed using STATA version 12.

    RESULTS: The sensitivity and specificity of ViroTrack were 62.3% (95%CI 55.6-68.7) and 95.0% (95%CI 91.7-97.3), versus 66.5% (95%CI 60.0-72.6) and 95.4% (95%CI 92.1-97.6) for SD NS1 ELISA, and 52.4% (95%CI 45.7-59.1) and 97.7% (95%CI 95.1-99.2) for NS1 component of SD Bioline, respectively. The combination of the latter with its IgM and IgG components were able to increase test sensitivity to 82.4% (95%CI 76.8-87.1) with corresponding decrease in specificity to 87.4% (95%CI 82.8-91.2). Although a positive test on any of the NS1 assays would increase the probability of dengue to above 90% in a patient, a negative result would only reduce this probability to 23.0-29.3%. In contrast, this probability of false negative diagnosis would be further reduced to 14.7% (95%CI 11.4-18.6) if SD Bioline NS1/IgM/IgG combo was negative.

    CONCLUSIONS: The performance of ViroTrack Dengue Acute was comparable to SD Dengue NS1 Ag ELISA. Addition of serology components to SD Bioline Dengue Duo significantly improved its sensitivity and reduced its false negative rate such that it missed the fewest dengue patients, making it a better point-of-care diagnostic tool. New RDT like ViroTrack Dengue Acute may be a potential alternative to existing RDT if its combination with serology components is proven better in future studies.

    Matched MeSH terms: Immunoglobulin M/blood
  8. Kari K, Liu W, Gautama K, Mammen MP, Clemens JD, Nisalak A, et al.
    BMC Med, 2006;4:8.
    PMID: 16603053
    Japanese encephalitis (JE) is presumed to be endemic throughout Asia, yet only a few cases have been reported in tropical Asian countries such as Indonesia, Malaysia and the Philippines. To estimate the true disease burden due to JE in this region, we conducted a prospective, hospital-based surveillance with a catchment population of 599,120 children less than 12 years of age in Bali, Indonesia, from July 2001 through December 2003.
    Matched MeSH terms: Immunoglobulin M/blood
  9. Rahmah N, Anuar AK
    Biochem Biophys Res Commun, 1992 Aug 31;187(1):294-8.
    PMID: 1520310
    C57BL/6 mice were orally infected with different doses of cysts of ME49 strain of Toxoplasma gondii to produce groups of acutely and chronically infected mice. Sera were obtained at different periods post-infection. SDS-PAGE was ran with excretory/secretory antigens of ME49 and RH strains of T. gondii, followed by Western blot analyses using the above sera and anti- IgA, IgM, IgG as conjugates. The SDS-PAGE profiles of the two antigens were similar. However the antigenic bands showed variations in all blots, most evidently in IgA blots of chronic sera. IgG blots showed greatest similarities in reactive bands. In IgM blots, more common bands were shown in chronic sera than in acute sera. Variations and similarities in prominence of some bands and time of their appearance were also noted, especially in IgM and IgG blots of chronic sera. Thus antigenic variations and similarities are present in excretory/secretory products of different strains of T. gondii.
    Matched MeSH terms: Immunoglobulin M/blood
  10. Mohamed S, May Amelia TS, Abdullah Amirul AA, Abdul Wahid ME, Bhubalan K
    Biologicals, 2021 Jun;71:51-54.
    PMID: 33858743 DOI: 10.1016/j.biologicals.2021.03.002
    A natural biodegradable polymer, polyhydroxyalkanoate (PHA), was adjuvanted with a vaccine seed to observe the biomaterial's ability in enhancing an immune response in rats. The adjuvant potential of PHA was tested using the whole-killed Pasteurella multocida B:2 (PMB2) vaccine in Sprague Dawley (SD) rats to detect changes in serum immunoglobulin G (IgG) and immunoglobulin M (IgM) responses. A common PHA, poly(3-hydroxybutyrate) [P(3HB)], from Bacillus megaterium UMTKB-1 was constructed into microparticles using the solvent evaporation method. Twelve SD rats were divided into four treatment groups: 1) non-treatment as negative control, 2) P(3HB) adjuvant, 3) PMB2 vaccine, and 4) adjuvanted-P(3HB)/PMB2 vaccine groups, which were intramuscularly vaccinated twice. Immunoglobulins IgG and IgM levels were used as markers of the immune response induced by the adjuvanted-P(3HB)/PMB2 vaccine and analysed over an eight-week study period. The group vaccinated specifically with adjuvanted-P(3HB)/PMB2 vaccine had higher concentrations of immunoglobulins compared to other treatment groups, hence demonstrating the potential of the adjuvant to enhance immune response. Findings showed a need to delay the delivery of the second booster dose to determine the appropriate regime for the adjuvanted-P(3HB)/PMB2 vaccine.
    Matched MeSH terms: Immunoglobulin M/blood
  11. Warrener L, Slibinskas R, Chua KB, Nigatu W, Brown KE, Sasnauskas K, et al.
    Bull World Health Organ, 2011 Sep 01;89(9):675-82.
    PMID: 21897488 DOI: 10.2471/BLT.11.088427
    OBJECTIVE: To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips.

    METHODS: The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips.

    FINDINGS: With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C.

    CONCLUSION: The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

    Matched MeSH terms: Immunoglobulin M/blood*
  12. Kit Lam S, Lan Ew C, Mitchell JL, Cuzzubbo AJ, Devine PL
    Clin Diagn Lab Immunol, 2000 Sep;7(5):850-2.
    PMID: 10973469
    A commercially available enzyme-linked immunosorbent assay (ELISA) (PanBio Dengue Screening ELISA) that utilized both immunoglobulin M (IgM) and IgG capture in the same microtiter well for the diagnosis of dengue infection was evaluated. Sensitivity in primary and secondary dengue was 95%, while specificity was 94%.
    Matched MeSH terms: Immunoglobulin M/blood*
  13. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Immunoglobulin M/blood*
  14. Lam SK, Fong MY, Chungue E, Doraisingham S, Igarashi A, Khin MA, et al.
    Clin Diagn Virol, 1996 Nov;7(2):93-8.
    PMID: 9137865 DOI: 10.1016/S0928-0197(96)00257-7
    The traditional methods used in the diagnosis of dengue infection do not lend themselves to field application. As such, clinical specimens have to be sent to a central laboratory for processing which invariably leads to delay. This affects patient management and disease control. The development of the dengue IgM dot enzyme immunoassay has opened up the possibility of carrying out the test in peripheral health settings.
    Matched MeSH terms: Immunoglobulin M/blood
  15. Hafner C, Koellner K, Vogt T, Landthaler M, Szeimies RM
    Hautarzt, 2006 Aug;57(8):705-7.
    PMID: 16283129
    A 39-year-old patient developed a disseminated rash with scattered petechiae, fever, malaise and arthralgia after a trip to Malaysia. The patient displayed increasing dengue IgG titers and borderline dengue IgM titers. Dengue fever with a hemorrhagic course is a rare condition in adult patients. Patients who have previously had dengue fever and retained non-neutralizing heterotypic antibodies are more likely to develop this complication via the phenomenon of antibody-dependent enhancement.
    Matched MeSH terms: Immunoglobulin M/blood
  16. Islam AH, Singh KK, Ismail A
    Diagn Microbiol Infect Dis, 2011 Jan;69(1):38-44.
    PMID: 21146712 DOI: 10.1016/j.diagmicrobio.2010.09.008
    Acinetobacter baumannii is an emerging nosocomial pathogen that is resistant to many types of antibiotics, and hence, a fast, sensitive, specific, and economical test for its rapid diagnosis is needed. Development of such a test requires a specific antigen, and outer membrane proteins (OMPs) are the prime candidates. The goal of this study was to find a specific OMP of A. baumannii and demonstrate the presence of specific IgM, IgA, and IgG against the candidate protein in human serum. OMPs of A. baumannii ATCC 19606 and 16 other clinical isolates of A. baumannii were extracted from an overnight culture grown at 37 °C. Protein profiles were obtained using sodium dodecyl sulfate polyacrylamide gel electrophoresis, and Western blot analysis was performed to detect the presence of IgM, IgA, and IgG against the OMP in host serum. An antigenic 34.4-kDa OMP was uniquely recognized by IgM, IgA, and IgG from patients with A. baumannii infection, and it did not cross-react with sera from patients with other types of infection. The band was also found in the other 16 A. baumannii isolates. This 34.4-kDa OMP is a prime candidate for development of a diagnostic test for the presence of A. baumannii.
    Matched MeSH terms: Immunoglobulin M/blood
  17. Chenthamarakshan V, Vadivelu J, Puthucheary SD
    Diagn Microbiol Infect Dis, 2001 Jan;39(1):1-7.
    PMID: 11173184
    IgM and IgG based ELISA systems were developed using the culture filtrate antigen (CFA) of Burkholderia pseudomallei. The assays were evaluated using 95 sera from 66 septicemic cases and 47 sera from 20 cases with localized melioidosis. In addition 65 sera from culture negative cases that were also serologically negative for other endemic infections clinically suspected of melioidosis were included. These were compared with sera from 260 non-melioidosis cases, 169 sera from individuals with high risk of acquiring the infection and 48 sera from healthy controls. The IgG-ELISA was 96% sensitive and 94% specific. All sera from cases with septicemic and localized infections and 61 of 63 sera from clinically suspected melioidosis cases were positive for IgG antibody. The geometric mean titre index (GMTI) values of IgG antibody in melioidosis cases were significantly higher (p < 0.0005) compared to that of healthy subjects, high risk group and subjects with non-melioidosis infections. The sensitivity and specificity of IgM ELISA was 74 and 99% respectively. The GMTI value of IgM antibody in the sera of melioidosis cases was significantly higher as compared to that of non-melioidosis disease controls (p < or = 0.001). These results demonstrate that the detection of IgG is a better indicator of the disease in the diagnosis of melioidosis.
    Matched MeSH terms: Immunoglobulin M/blood*
  18. Chadha MS, Comer JA, Lowe L, Rota PA, Rollin PE, Bellini WJ, et al.
    Emerg Infect Dis, 2006 Feb;12(2):235-40.
    PMID: 16494748
    During January and February 2001, an outbreak of febrile illness associated with altered sensorium was observed in Siliguri, West Bengal, India. Laboratory investigations at the time of the outbreak did not identify an infectious agent. Because Siliguri is in close proximity to Bangladesh, where outbreaks of Nipah virus (NiV) infection were recently described, clinical material obtained during the Siliguri outbreak was retrospectively analyzed for evidence of NiV infection. NiV-specific immunoglobulin M (IgM) and IgG antibodies were detected in 9 of 18 patients. Reverse transcription-polymerase chain reaction (RT-PCR) assays detected RNA from NiV in urine samples from 5 patients. Sequence analysis confirmed that the PCR products were derived from NiV RNA and suggested that the NiV from Siliguri was more closely related to NiV isolates from Bangladesh than to NiV isolates from Malaysia. NiV infection has not been previously detected in India.
    Matched MeSH terms: Immunoglobulin M/blood
  19. Lau YL, Fong MY
    Exp Parasitol, 2008 Jul;119(3):373-8.
    PMID: 18457835 DOI: 10.1016/j.exppara.2008.03.016
    The full length surface antigen 2 (SAG2) gene of the protozoan parasite Toxoplasma gondii was cloned and intracellularly expressed in the Pichia pastoris expression system. The molecular weight of the expressed recombinant SAG2 (36 kDa) was much larger than the native SAG2 (22 kDa). This discrepancy in size was due to hyperglycosylation, as deglycosylation assay reduced the size of the recombinant SAG2 to 22 kDa. Despite being hyperglycosylated, the recombinant SAG2 reacted strongly with pooled anti-Toxoplasma human serum, pooled anti-Toxoplasma mouse serum and a SAG2-specific monoclonal antibody. The glycosylated recombinant SAG2 was further evaluated in Western blot and in-house enzyme-linked immunosorbent assay (ELISA) using 80 human serum samples, including confirmed early acute (IgM positive, IgG negative; n=20), acute (IgM positive, IgG positive; n=20) and chronic (IgM negative, IgG positive; n=20) toxoplasmosis patients, and toxoplasmosis negative control patients (n=20). Results of the Western blot showed that the recombinant SAG2 reacted with all 60 samples of the toxoplasmosis cases but not with the Toxoplasma-negative samples. The sensitivity of in-house ELISA was 80%, 95% and 100% for early acute, acute and chronic patients' serum samples, respectively. Vaccination study showed that serum from mice immunised with the glycosylated recombinant SAG2 reacted specifically with the native SAG2 of T. gondii. The mice were significantly protected against lethal challenge with live T. gondii RH strain tachyzoites (P<0.01) and their survival time was increased compared to controls. Therefore, the present study shows that the P. pastoris-derived recombinant SAG2 was specific and suitable for use as antigen for detecting anti-Toxoplasma IgG and IgM antibodies. The vaccination study showed that recombinant SAG2 protein was immunoprotective in mice against lethal challenge.
    Matched MeSH terms: Immunoglobulin M/blood
  20. Miyaji K, Shahrizaila N, Umapathi T, Chan YC, Hirata K, Yuki N
    Hum Immunol, 2014 Nov;75(11):1089-91.
    PMID: 25286001 DOI: 10.1016/j.humimm.2014.09.010
    Ezrin, radixin and moesin, which are strongly expressed in the Schwann cell microvilli, are putative targets for autoantibodies in acute or chronic inflammatory demyelinating polyneuropathy (AIDP or CIDP). An association between anti-moesin IgG antibodies and cytomegalovirus-related AIDP has been postulated. None of 41 AIDP patients, including 8 cytomegalovirus-related AIDP patients, and 23 CIDP had IgG or IgM antibodies to ezrin, radixin and moesin; whereas, one patient with cytomegalovirus-related AIDP had anti-ezrin IgM antibodies. Ezrin, radixin and moesin are unlikely targets for autoantibodies in AIDP and CIDP, and the association of anti-moesin antibodies with cytomegalovirus-related AIDP was not confirmed.
    Matched MeSH terms: Immunoglobulin M/blood
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links