Displaying publications 1 - 20 of 117 in total

Abstract:
Sort:
  1. Che Ab Aziz, Z.A.
    Ann Dent, 2008;15(2):67-70.
    MyJurnal
    Aim: To manufacture a clinical simulation apparatus for the undergraduates' endodontic radiography teaching Objectives: • To provide a model for teaching of parallax method using Kelly's forcep • To provide a model for undergraduates to practice radiographic localization employing parallax method. • To allow students to practice taking radiographs in a way that simulates the clinical situations with a good diagnostic quality Methods: Impressions of a dentate arch (maxillary and mandibullary) were used to form a stone cast. A section of the cast, in the area where the natural teeth were to be placed, is sectioned and removed. Three maxillary extracted teeth (canine, first and second premolar) were selected and mounted with acrylic resin at the sectioned area. The resin was cured in a light box. The arches were mounted in a phantom head with a placement of rubber cheek. The first premolar was isolated with rubber dam. The intraoral holder (Kelly's forcep) was attached to a robotic arm. The students were taught the correct angulations of the x-ray cone for the paralleling technique and parallax method using Kelly's forcep during root canal treatment. Results: All students managed to complete the exercise and were considered competent when they produced acceptable quality of radiographs. Conclusion: The model described was improvised from a model that has been used during the past 2 years for undergraduates' endodontic courses. It has been well accepted as it simulates the clinical situation more closely than was possible previously.
    Matched MeSH terms: Phantoms, Imaging
  2. Said MA, Musarudin M, Zulkaffli NF
    Ann Nucl Med, 2020 Dec;34(12):884-891.
    PMID: 33141408 DOI: 10.1007/s12149-020-01543-x
    OBJECTIVE: 18F is the most extensively used radioisotope in current clinical practices of PET imaging. This selection is based on the several criteria of pure PET radioisotopes with an optimum half-life, and low positron energy that contributes to a smaller positron range. In addition to 18F, other radioisotopes such as 68Ga and 124I are currently gained much attention with the increase in interest in new PET tracers entering the clinical trials. This study aims to determine the minimal scan time per bed position (Tmin) for the 124I and 68Ga based on the quantitative differences in PET imaging of 68Ga and 124I relative to 18F.

    METHODS: The European Association of Nuclear Medicine (EANM) procedure guidelines version 2.0 for FDG-PET tumor imaging has adhered for this purpose. A NEMA2012/IEC2008 phantom was filled with tumor to background ratio of 10:1 with the activity concentration of 30 kBq/ml ± 10 and 3 kBq/ml ± 10% for each radioisotope. The phantom was scanned using different acquisition times per bed position (1, 5, 7, 10 and 15 min) to determine the Tmin. The definition of Tmin was performed using an image coefficient of variations (COV) of 15%.

    RESULTS: Tmin obtained for 18F, 68Ga and 124I were 3.08, 3.24 and 32.93 min, respectively. Quantitative analyses among 18F, 68Ga and 124I images were performed. Signal-to-noise ratio (SNR), contrast recovery coefficients (CRC), and visibility (VH) are the image quality parameters analysed in this study. Generally, 68Ga and 18F gave better image quality as compared to 124I for all the parameters studied.

    CONCLUSION: We have defined Tmin for 18F, 68Ga and 124I SPECT CT imaging based on NEMA2012/IEC2008 phantom imaging. Despite the long scanning time suggested by Tmin, improvement in the image quality is acquired especially for 124I. In clinical practice, the long acquisition time, nevertheless, may cause patient discomfort and motion artifact.

    Matched MeSH terms: Phantoms, Imaging
  3. Marashdeh MW, Bauk S, Tajuddin AA, Hashim R
    Appl Radiat Isot, 2012 Apr;70(4):656-62.
    PMID: 22304963 DOI: 10.1016/j.apradiso.2012.01.008
    The mass attenuation coefficients of Rhizophora spp. binderless particleboard with four different particle sizes (samples A, B, C and D) and natural raw Rhizophora spp. wood (sample E) were determined using single-beam photon transmission in the energy range between 16.59 and 25.26 keV. This was done by determining the attenuation of K(α1) X-ray fluorescent (XRF) photons from niobium, molybdenum, palladium, silver and tin targets. The results were compared with theoretical values of young-age breast (Breast 1) and water calculated using a XCOM computer program. It was found that the mass attenuation coefficient of Rhizophora spp. binderless particleboards to be close to the calculated XCOM values in water than natural Rhizophora spp. wood. Computed tomography (CT) scans were then used to determine the density profile of the samples. The CT scan results showed that the Rhizophora spp. binderless particleboard has uniform density compared to natural Rhizophora spp. wood. In general, the differences in the variability of the profile density decrease as the particle size of the pellet samples decreases.
    Matched MeSH terms: Phantoms, Imaging/standards*
  4. Bradley DA, Wong CS, Ng KH
    Appl Radiat Isot, 2000 9 26;53(4-5):691-7.
    PMID: 11003508
    For broad-beam soft X-ray sources, assessment of the quality of image produced by such units is made complex by the low penetration capabilities of the radiation. In the present study we have tested the utility of several types of test tool, some of which have been fabricated by us, as part of an effort to evaluate several key image defining parameters. These include the film characteristic, focal-spot size, image resolution and detail detectability. The two sources of X-rays used in present studies were the University of Malaya flash X-ray device (UMFX1) and a more conventional soft X-ray tube (Softex, Tokyo), the latter operating at peak accelerating potentials of 20 kVp. We have established, for thin objects, that both systems produce images of comparable quality and, in particular, objects can be resolved down to better than 45 microm.
    Matched MeSH terms: Phantoms, Imaging
  5. Banjade DP, Tajuddin AA, Shukri A
    Appl Radiat Isot, 2001 Sep;55(3):297-302.
    PMID: 11515650
    Previous scattering and depth-dose investigations involving use of the Malaysian hardwood Rhizophora spp have shown this medium to produce good agreement with measurements made in water. Present study extends the comparison, now including measurements of percentage depth-dose made for photons at 6MV and 5 and 12MeV electron beams. For the 6 MV photon and 5 MeV electron beams, discrepancies between percentage depth-dose for Rhizophora spp and water, at all depths, are found to be within 2.6 and 2.4% respectively. At 12 MeV electron energies, measured percentage depth-doses in Rhizophora spp beyond 3.5cm depth are found to be in significant discord with those for water. The absorbed dose in water measured in Rhizophora spp at d(max) for all three beams produces discrepancies of no more than 1.1% when compared with measurements made in water.
    Matched MeSH terms: Phantoms, Imaging*
  6. Banjade DP, Tajuddin AA, Shukri A
    Appl Radiat Isot, 2001 Aug;55(2):235-43.
    PMID: 11393765
    Protocols developed for high-energy dosimetry IAEA (Technical Reports Series No. 277, 1997), AAPM (Med. Phys. 10 (1983) 741: Med. Phys. 18 (1991) 73: Med. Phys. 21 (1994) 1251), IPEMB (Phys. Med. Biol. 41 (1996) 2557), and HPA (Phys. Med. Biol. 28 (1983) 1097) have continued to enhance precision in dose measurements and the optimization of radiotherapy procedures. While recent dosimetry protocols, including those due to the IAEA and IPEMB, have made a number of improvements compared with previous protocols, it is further desirable to develop absolute dosimetry methods of dose measurements. Measurements based on careful implementation of procedures contained within the various protocols have been carried out in an effort to determine the extent to which discrepancies exist among the protocols. Dose in water at dmax was measured using cylindrical and parallel-plate ionization chambers for 6 MV photon beams and 5 and 12 MeV electron beams. Results obtained from the use of the AAPM and HPA protocols for 6 MV photon beams were found to be 0.9% larger and 0.1% smaller, respectively, than those measured following the IAEA protocol. Calibration dose measurements for 5 and 12 MeV electron beams in water phantoms were found to agree to within 1%, this being well within recommendations from the ICRU and other sources regarding the accuracy of dose delivery.
    Matched MeSH terms: Phantoms, Imaging*
  7. Lee KH, Kandaiya S
    Appl Radiat Isot, 1996 Mar;47(3):361-3.
    PMID: 8935969
    Matched MeSH terms: Phantoms, Imaging
  8. Zuber SH, Hashikin NAA, Mohd Yusof MF, Aziz MZA, Hashim R
    Appl Radiat Isot, 2021 Apr;170:109601.
    PMID: 33515930 DOI: 10.1016/j.apradiso.2021.109601
    Experimental particleboards are made from Rhizophora spp. wood trunk with three different percentages of lignin and soy flour (0%, 6% and 12%) as adhesives. The objective was to investigate the equivalence of Rhizophora spp. particleboard as phantom material with human soft tissue using Computed Tomography (CT) number. The linear and mass attenuation coefficient of Rhizophora spp. particleboard at low energy range was also explored using X-ray Fluorescence (XRF) configuration technique. Further characterization of the particleboard was performed to determine the effective atomic number, Zeff using Energy Dispersive X-Ray (EDX) method. Adhesive-bonded Rhizophora spp. particleboard showed close similarities with water, based on the average CT numbers, electron density calibration curve and the analysis of CT density profile, compared to the binderless particleboard. The effective atomic number obtained from the study indicated that the attenuation properties of all the particleboards at different percentages of adhesives were almost similar to water. The mass attenuation coefficient calculated from XRF configuration technique showed good agreement with water from XCOM database, suggesting its potential as phantom material for radiation study.
    Matched MeSH terms: Phantoms, Imaging
  9. Sanusi MSM, Hassan WMSW, Hashim S, Ramli AT
    Appl Radiat Isot, 2021 Aug;174:109791.
    PMID: 34062400 DOI: 10.1016/j.apradiso.2021.109791
    Terrestrial radioactivity monitoring of 238U and 232Th series, and 40K in soil is an essential practice for radioactivity and radiation measurement of a place. In conventional practice, only basic data can be in-situ measured using a survey instrument, for example radioactivity concentration in soil and ambient dose equivalent rate. For other physical quantities, for example organ absorbed dose and organ equivalent dose, the measurement is impossible to be performed and can only be computed using Monte Carlo radiation transport simulations. In the past, most of the works only focused on calculating air-kerma-to-effective dose conversion factors. However, the information on organ dose conversion factors is scarcely documented and reported. This study was conducted to calculate organ absorbed and tissue-weighted equivalent dose conversion factors as a result of exposure from terrestrial gamma radiation. Series of organ dose conversion factors is produced based on computations from Monte Carlo MCNP5 simulations using modelled gamma irradiation geometry and established adult MIRD phantom. The study found out that most of the radiation exposed organs absorb energy at comparable rates, except for dense and superficial tissues i.e., skeleton and skin, which indicated slightly higher values. The good agreement between this work and previous studies demonstrated that our gamma irradiation geometry and modelling of gamma radiation sources are adequate. Therefore, the proposed organ dose conversion factors from this study are reasonably acceptable for dose estimation in environmental radioactivity monitoring practices.
    Matched MeSH terms: Phantoms, Imaging
  10. Waeleh N, Saripan MI, Musarudin M, Mashohor S, Ahmad Saad FF
    Appl Radiat Isot, 2021 Oct;176:109885.
    PMID: 34385090 DOI: 10.1016/j.apradiso.2021.109885
    The present study was conducted to determine quantitatively the correlation between injected radiotracer and signal-to-noise ratio (SNR) based on differences in physiques and stages of cancer. Eight different activities were evaluated with modelled National Electrical Manufacturers Association (NEMA) of the International Electrotechnical Commission (IEC) PET's phantom with nine different tumour-to-background ratio (TBR). The findings suggest that the optimal value of dosage is required for all categories of patients in the early stages of cancer diagnosis.
    Matched MeSH terms: Phantoms, Imaging*
  11. Alsadig AA, Abbas S, Kandaiya S, Ashikin NARNN, Qaeed MA
    Appl Radiat Isot, 2017 Nov;129:130-134.
    PMID: 28843699 DOI: 10.1016/j.apradiso.2017.08.021
    Phantoms are devices that simulate human tissues including soft tissues, lungs, and bones in medical and health physics. The purpose of this work was to investigate the differential dose absorption in several commercially available low-cost materials as substitutes to human tissues using Gafchromic XR-QA2 film. The measurement of absorbed dose by different materials of various densities was made using the film to establish the relationship between the absorbed dose and the material density. Materials investigated included soft board materials, Perspex, chicken bone, Jeltrate, chalk, cow bone, marble, and aluminum, which have varying densities from 0.26 to 2.67gcm-3. The absorbed dose increased as the density and atomic number of the material increased. The absorbed dose to the density can be well represented by a polynomial function for the materials used.
    Matched MeSH terms: Phantoms, Imaging*
  12. Aminah M, Ng KH, Abdullah BJ, Jamal N
    Australas Phys Eng Sci Med, 2010 Dec;33(4):329-34.
    PMID: 20938762 DOI: 10.1007/s13246-010-0035-3
    The performance of a digital mammography system (Siemens Mammomat Novation) using different target/filter combinations and tube voltage has been assessed. The objective of this study is to optimize beam quality selection based on contrast-to-noise ratio (CNR) and mean glandular dose (MGD). Three composition of breast were studied with composition of glandular/adipose of 30/70, 50/50, and 70/30. CNR was measured using 2, 4 and 6 cm-thick simulated breast phantoms with an aluminium sheet of 0.1 mm thickness placed on top of the phantom. Three target/filter combinations, namely molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh) and tungsten/rhodium (W/Rh) with various tube voltage and mAs were tested. MGD was measured for each exposure. For 50/50 breast composition, Mo/Rh combination with tube voltage 26 kVp is optimal for 2 cm-thick breast. W/Rh combination with tube voltage 27 and 28 kVp are optimal for 4 and 6 cm-thick breast, respectively. For both 30/70 and 70/30 breast composition, W/Rh combination is optimal with tube voltage 25, 26 and 27 kVp, respectively. From our study it was shown that there are potential of dose reduction up to 11% for a set CNR of 3.0 by using beam quality other than that are determined by AEC selection. Under the constraint of lowest MGD, for a particular breast composition, calcification detection is optimized by using a softer X-ray beam for thin breast and harder X-ray beam for thick breast. These experimental results also indicate that for breast with high fibroglandular tissues (70/30), the use of higher beam quality does not always increase calcification detection due to additional structured noise caused by the fibroglandular tissues itself.
    Matched MeSH terms: Phantoms, Imaging
  13. Alzoubi AS, Kandaiya S, Shukri A, Elsherbieny E
    Australas Phys Eng Sci Med, 2010 Jun;33(2):137-44.
    PMID: 20309667 DOI: 10.1007/s13246-010-0011-y
    Second cancer induction in the contralateral breast (CB) is an issue of some concern in breast radiotherapy especially for women under the age of 45 years at the time of treatment. The CB dose from 2-field and 3-field techniques in post-mastectomy chest wall irradiations in an anthropomorphic phantom as well as in patients were measured using thermoluminescent dosimeters (TLDs) at the local radiotherapy center. Breast and chest wall radiotherapy treatments were planned conformally (3D-CRT) and delivered using 6-MV photons. The measured CB dose at the surface fell sharply with distance from the field edge. However, the average ratio of the measured to the calculated CB dose using the pencil beam algorithm at the surface was approximately 53%. The mean and median measured internal dose at the posterior border of CB in a phantom was 5.47+/-0.22 cGy and 5.44 cGy, respectively. The internal CB dose was relatively independent of depth. In the present study the internal CB dose is 2.1-4.1% of the prescribed dose which is comparable to the values reported by other authors.
    Matched MeSH terms: Phantoms, Imaging
  14. Banjade DP, Shrestha SL, Shukri A, Tajuddin AA, Bhat M
    Australas Phys Eng Sci Med, 2002 Sep;25(3):110-8.
    PMID: 12416587
    This is a study using LiF:Mg;Ti thermoluminescent dosimeter (TLD) rods in phantoms to investigate the effect of lack of backscatter on exit dose. Comparing the measured dose with anticipated dose calculated using tissue maximum ratio (TMR) or percentage depth dose (PDD) gives rise to a correction factor. This correction factor may be applied to in-vivo dosimetry results to derive true dose to a point within the patient. Measurements in a specially designed humanoid breast phantom as well as patients undergoing radiotherapy treatment were also been done. TLDs with reproducibility of within +/- 3% (1 SD) are irradiated in a series of measurements for 6 and 10 MV photon beams from a medical linear accelerator. The measured exit doses for the different phantom thickness for 6 MV beams are found to be lowered by 10.9 to 14.0% compared to the dose derived from theoretical estimation (normalized dose at dmax). The same measurements for 10 MV beams are lowered by 9.0 to 13.5%. The variations of measured exit dose for different field sizes are found to be within 2.5%. The exit doses with added backscatter material from 2 mm up to 15 cm, shows gradual increase and the saturated values agreed within 1.5% with the expected results for both beams. The measured exit doses in humanoid breast phantom as well as in the clinical trial on patients undergoing radiotherapy also agreed with the predicted results based on phantom measurements. The authors' viewpoint is that this technique provides sufficient information to design exit surface bolus to restore build down effect in cases where part of the exit surface is being considered as a target volume. It indicates that the technique could be translated for in vivo dose measurements, which may be a conspicuous step of quality assurance in clinical practice.
    Matched MeSH terms: Phantoms, Imaging*
  15. Ng K, Pirabul R, Peralta A, Soejoko D
    Australas Phys Eng Sci Med, 1997 Mar;20(1):27-32.
    PMID: 9141310
    In recent years there has been a significant economic growth in South East Asia, along with it a concurrent development of medical physics. The status of four countries--Malaysia, Thailand, the Philippines and Indonesia are presented. Medical physicists in these countries have been experiencing the usual problems of lack of recognition, low salaries, and insufficient facilities for education and training opportunities. However the situation has improved recently through the initiative of local enthusiastic medical physicists who have started MS graduate programs in medical physics and begun organizing professional activities to raise the profile of medical physics. The tremendous support and catalytic roles of the American Association of Physicists in Medicine (AAPM) and international organizations such as International Organization for Medical Physics (IOMP), International Atomic Energy Agency (IAEA), World Health Organization (WHO), and International Center for Theoretical Physics (ICTP) have been instrumental in achieving progress. Contributions by these organizations include co-sponsorship of workshops and conferences, travel grants, medical physics libraries programs, and providing experts and educators. The demand for medical physicists is expected to rise in tandem with the increased emphasis on innovative technology for health care, stringent governmental regulation, and acceptance by the medical community of the important role of medical physicists.
    Matched MeSH terms: Phantoms, Imaging
  16. Rejab M, Wong JHD, Jamalludin Z, Jong WL, Malik RA, Wan Ishak WZ, et al.
    Australas Phys Eng Sci Med, 2018 Jun;41(2):475-485.
    PMID: 29756166 DOI: 10.1007/s13246-018-0647-6
    This study investigates the characteristics and application of the optically-stimulated luminescence dosimeter (OSLD) in cobalt-60 high dose rate (HDR) brachytherapy, and compares the results with the dosage produced by the treatment planning system (TPS). The OSLD characteristics comprised linearity, reproducibility, angular dependence, depth dependence, signal depletion, bleaching rate and cumulative dose measurement. A phantom verification exercise was also conducted using the Farmer ionisation chamber and in vivo diodes. The OSLD signal indicated a supralinear response (R2 = 0.9998). It exhibited a depth-independent trend after a steep dose gradient region. The signal depletion per readout was negligible (0.02%), with expected deviation for angular dependence due to off-axis sensitive volume, ranging from 1 to 16%. The residual signal of the OSLDs after 1 day bleached was within 1.5%. The accumulated and bleached OSLD signals had a standard deviation of ± 0.78 and ± 0.18 Gy, respectively. The TPS was found to underestimate the measured doses with deviations of 5% in OSLD, 17% in the Farmer ionisation chamber, and 7 and 8% for bladder and rectal diode probes. Discrepancies can be due to the positional uncertainty in the high-dose gradient. This demonstrates a slight displacement of the organ at risk near the steep dose gradient region will result in a large dose uncertainty. This justifies the importance of in vivo measurements in cobalt-60 HDR brachytherapy.
    Matched MeSH terms: Phantoms, Imaging
  17. Ramli K, Abdullah BJ, Ng KH, Mahmud R, Hussain AF
    Australas Radiol, 2005 Dec;49(6):460-6.
    PMID: 16351609
    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P > 0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (chi(2) tests).
    Matched MeSH terms: Phantoms, Imaging
  18. Chew KM, Seman N, Sudirman R, Yong CY
    Biomed Mater Eng, 2014;24(6):2161-7.
    PMID: 25226914 DOI: 10.3233/BME-141027
    The development of human-like brain phantom is important for data acquisition in microwave imaging. The characteristics of the phantom should be based on the real human body dielectric properties such as relative permittivity. The development of phantom includes the greymatter and whitematter regions, each with a relative permittivity of 38 and 28 respectively at 10 GHz frequency. Results were compared with the value obtained from the standard library of Computer Simulation Technology (CST) simulation application and the existing research by Fernandez and Gabriel. Our experimental results show a positive outcome, in which the proposed mixture was adequate to represent real human brain for data acquisition.
    Matched MeSH terms: Phantoms, Imaging*
  19. Chew KM, Sudirman R, Seman N, Yong CY
    Biomed Mater Eng, 2014;24(1):199-207.
    PMID: 24211899 DOI: 10.3233/BME-130800
    The study was conducted based on two objectives as framework. The first objective is to determine the point of microwave signal reflection while penetrating into the simulation models and, the second objective is to analyze the reflection pattern when the signal penetrate into the layers with different relative permittivity, εr. Thus, several microwave models were developed to make a close proximity of the in vivo human brain. The study proposed two different layers on two different characteristics models. The radii on the second layer and the corresponding antenna positions are the factors for both models. The radii for model 1 is 60 mm with an antenna position of 10 mm away, in contrast, model 2 is 10 mm larger in size with a closely adapted antenna without any gap. The layers of the models were developed with different combination of materials such as Oil, Sandy Soil, Brain, Glycerin and Water. Results show the combination of Glycerin + Brain and Brain + Sandy Soil are the best proximity of the in vivo human brain grey and white matter. The results could benefit subsequent studies for further enhancement and development of the models.
    Matched MeSH terms: Phantoms, Imaging
  20. Yahya N, Kamel NS, Malik AS
    Biomed Eng Online, 2014;13(1):154.
    PMID: 25421914 DOI: 10.1186/1475-925X-13-154
    Ultrasound imaging is a very essential technique in medical diagnosis due to its being safe, economical and non-invasive nature. Despite its popularity, the US images, however, are corrupted with speckle noise, which reduces US images qualities, hampering image interpretation and processing stage. Hence, there are many efforts made by researches to formulate various despeckling methods for speckle reduction in US images.
    Matched MeSH terms: Phantoms, Imaging