Displaying publications 1 - 20 of 39 in total

Abstract:
Sort:
  1. Chua KB
    Microbes Infect., 2003 May;5(6):487-90.
    PMID: 12758277
    During the outbreak of Nipah virus encephalitis involving pigs and humans in peninsular Malaysia in 1998/1999, a conventional approach was initially undertaken to collect specimens from fruit bats by mist-netting and shooting, as an integral part of wildlife surveillance of the natural reservoir host of Nipah virus. This study describes a novel method of collecting fruit bats' urine samples using plastic sheets for isolation of Nipah virus. This novel approach resulted in the isolation of several other known and unidentified infectious agents besides Nipah virus.
    Matched MeSH terms: Specimen Handling/methods*
  2. Lim KL, Johari NA, Wong ST, Khaw LT, Tan BK, Chan KK, et al.
    PLoS One, 2020;15(8):e0238417.
    PMID: 32857823 DOI: 10.1371/journal.pone.0238417
    The rapid global spread of the coronavirus disease (COVID-19) has inflicted significant health and socioeconomic burden on affected countries. As positive cases continued to rise in Malaysia, public health laboratories experienced an overwhelming demand for COVID-19 screening. The confirmation of positive cases of COVID-19 has solely been based on the detection of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) using real-time reverse transcription polymerase chain reaction (qRT-PCR). In efforts to increase the cost-effectiveness and efficiency of COVID-19 screening, we evaluated the feasibility of pooling clinical Nasopharyngeal/Oropharyngeal (NP/OP) swab specimens during nucleic acid extraction without a reduction in sensitivity of qRT-PCR. Pools of 10 specimens were extracted and subsequently tested by qRT-PCR according to the WHO-Charité protocol. We demonstrated that the sample pooling method showed no loss of sensitivity. The effectiveness of the pooled testing strategy was evaluated on both retrospective and prospective samples, and the results showed a similar detection sensitivity compared to testing individual sample alone. This study demonstrates the feasibility of using a pooled testing strategy to increase testing capacity and conserve resources, especially when there is a high demand for disease testing.
    Matched MeSH terms: Specimen Handling/methods*
  3. Rashid Ali MR, Parameswaran U, William T, Bird E, Wilkes CS, Lee WK, et al.
    Int J Tuberc Lung Dis, 2015 May;19(5):620-1.
    PMID: 25868033 DOI: 10.5588/ijtld.14.0938
    Matched MeSH terms: Specimen Handling/methods
  4. Shafie IN, Anderson TJ, Penderis J, Eckersall PD, McLaughlin M
    Vet J, 2013 Sep;197(3):836-41.
    PMID: 23820135 DOI: 10.1016/j.tvjl.2013.05.039
    Cerebrospinal fluid (CSF) is a potential source for disease-specific biomarkers that may assist in the staging and determining the prognosis of neurodegenerative conditions in animals. However, the validity of such putative biomarkers may be influenced by pre-analytical variables, including the procedures adopted to collect and store the CSF. This study assessed the effect of three handling practices on the stability of a panel of CSF proteins: clusterin (also known as apolipoprotein J), haptoglobin, cystatin C, and transthyretin (TTR). The three handling procedures for canine CSF were mimicked in the laboratory as follows: (1) storage in a refrigerator overnight (4 °C for 18 h); (2) carrying a sample in the pocket of a clinician (37 °C for 4h); and (3) mailing a sample to a remote laboratory for analysis (room temp for 48 h). The impact of these three scenarios on the concentrations of the selected proteins was assessed using Western blotting and compared to an aliquot of CSF that had been kept frozen. The level of clusterin was significantly reduced following 48 h at room temperature (P<0.05), while the concentration of the dimeric form of TTR increased following this handling procedure and also when held at 37 °C for 4h. A reducing agent prevented this increase at 37 °C. In conclusion, exposing CSF samples to various environmental conditions can significantly alter their protein content, a factor that must be considered in studies assessing potential biomarkers in canine CSF.
    Matched MeSH terms: Specimen Handling/methods
  5. Morgan K, Azzani M, Khaing SL, Wong YL, Su TT
    J Low Genit Tract Dis, 2019 Jul;23(3):193-199.
    PMID: 30933030 DOI: 10.1097/LGT.0000000000000476
    OBJECTIVES: Female self-sampling for human papillomavirus (HPV) DNA testing is an alternative screening method that can potentially increase cervical cancer screening coverage. This review addresses the acceptability of HPV DNA testing using self-sampling compared with conventional clinician-collected sampling. Barriers to and others factors associated with acceptability of either method were also examined.

    METHODS: The following electronic resources were searched: Medline @EBSCOHOST(Medline), Embase, PubMed, and CINAHL databases. Manual searches were also conducted. The main outcome of interest was the acceptability of HPV DNA testing by self-sampling in comparison with clinician-collected sampling.

    RESULTS: In total, 23 articles were included in this systematic review. The majority (19 studies) were quantitative intervention studies and 4 studies were qualitative observational studies. Eleven studies reported a preference for self-sampling by women compared with clinician-collected sampling (64.7%-93%). The remaining studies found that women preferred clinician-collected sampling because mainly of respondents' lack of confidence in their ability to complete self-sampling correctly. In most articles reviewed, the studied associated factors, such as demographic factors (age, marital status, and ethnicity), socioeconomic factors (income, education level), reproductive factors (condom use, number of children, current use of contraception, and number of partners), and habits (smoking status) were not found to be significantly associated with preference.

    CONCLUSIONS: Both methods of sampling were found to be acceptable to women. Self-sampling is cost-effective and could increase the screening coverage among underscreened populations. However, more information about the quality, reliability, and accuracy of self-sampling is needed to increase women's confidence about using to this method.

    Matched MeSH terms: Specimen Handling/methods*
  6. Othman N, Othman NH
    Malays J Pathol, 2012 Dec;34(2):115-21.
    PMID: 23424773 MyJurnal
    The aim of this study was to examine cells (split-sample) that were retained on sampling devices used to collect conventional Pap smears (primary smears) in order to evaluate specimen adequacy and cytological diagnosis of scrapings that are routinely discarded.
    Matched MeSH terms: Specimen Handling/methods*
  7. Srijaya TC, Ramasamy TS, Kasim NH
    J Transl Med, 2014;12:243.
    PMID: 25182194 DOI: 10.1186/s12967-014-0243-9
    The inadequacy of existing therapeutic tools together with the paucity of organ donors have always led medical researchers to innovate the current treatment methods or to discover new ways to cure disease. Emergence of cell-based therapies has provided a new framework through which it has given the human world a new hope. Though relatively a new concept, the pace of advancement clearly reveals the significant role that stem cells will ultimately play in the near future. However, there are numerous uncertainties that are prevailing against the present setting of clinical trials related to stem cells: like the best route of cell administration, appropriate dosage, duration and several other applications. A better knowledge of these factors can substantially improve the effectiveness of disease cure or organ repair using this latest therapeutic tool. From a certain perspective, it could be argued that by considering certain proven clinical concepts and experience from synthetic drug system, we could improve the overall efficacy of cell-based therapies. In the past, studies on synthetic drug therapies and their clinical trials have shown that all the aforementioned factors have critical ascendancy over its therapeutic outcomes. Therefore, based on the knowledge gained from synthetic drug delivery systems, we hypothesize that by employing many of the clinical approaches from synthetic drug therapies to this new regenerative therapeutic tool, the efficacy of stem cell-based therapies can also be improved.
    Matched MeSH terms: Specimen Handling/methods
  8. Salleh FM, Moktar N, Yasin AM, Al-Mekhlafi HM, Anuar TS
    J Microbiol Methods, 2014 Nov;106:143-145.
    PMID: 25193442 DOI: 10.1016/j.mimet.2014.08.019
    To improve the stool concentration procedure, we modified different steps of the standard formalin-ether concentration technique and evaluated these modifications by examining stool samples collected in the field. Seven samples were found positive by the modified formalin-ether concentration technique (M-FECT). Therefore, the M-FECT procedure provides enhanced detection of Cryptosporidium oocysts.
    Matched MeSH terms: Specimen Handling/methods*
  9. Tan EL, Peh SC, Sam CK
    J Med Virol, 2003 Feb;69(2):251-7.
    PMID: 12683415
    Nasopharyngeal carcinoma, a malignancy associated closely with Epstein-Barr virus (EBV), is prevalent among Chinese of Southern China origin. Epidemiological studies indicate a high prevalence of EBV in Asia with viral isolates having typical characteristics of the putative viral oncogene, latent membrane protein 1 (LMP-1), such as the loss of the Xho1 restriction site in Exon 1 and the 30-bp deletion in Exon 3. The EBV LMP-1 gene from throat washings of 120 nasopharyngeal carcinoma patients and 14 healthy individuals were analyzed. Similar analyses were also carried out on 30 and 12 postnasal space biopsies from nasopharyngeal carcinoma patients and healthy individuals, respectively. The 30-bp deletion was detected in 20% of nasopharyngeal carcinoma throat washes and in 100% of nasopharyngeal carcinoma postnasal space biopsies. Interestingly, 16% of the nasopharyngeal carcinoma biopsies possessed both the deleted and the undeleted variants, suggestive of dual infections. The notion of dual infections in nasopharyngeal carcinoma was further supported by the coexistence of both "F" and "f" (BamH1F region) EBV variants in 11% of the nasopharyngeal carcinoma biopsies. All of the throat washes and biopsies from the healthy controls showed the undeleted variant. The loss of the Xho1 restriction site was found with higher frequency both in throat washes and biopsies from patients with nasopharyngeal carcinoma. The discrepancy in the frequency of the 30-bp deletion between throat washes (20%) and postnasal space biopsies (100%) was an indication that this deletion is specific for viral isolates from primary tumour sites.
    Matched MeSH terms: Specimen Handling/methods
  10. Saville M, Hawkes D, Keung M, Ip E, Silvers J, Sultana F, et al.
    J Clin Virol, 2020 06;127:104375.
    PMID: 32361328 DOI: 10.1016/j.jcv.2020.104375
    BACKGROUND: In the last decade, human papillomavirus (HPV) testing has been evaluated extensively for cervical screening, with studies finding increased sensitivity compared to cytology. Another advantage of HPV based-screening is the ability to test vaginal samples that can be collected by women themselves. Self-collection has the potential to extend cervical screening coverage by increasing participation rates, particularly among women who are under-screened or have never screened. This could have a significant impact on cervical cancer prevention, as the majority of invasive cervical cancer cases occur among under-screened women. Both the Netherlands and Australia have transitioned their national programs from cytology to HPV as the primary screening test and both countries include a pathway for self-collection.

    OBJECTIVES: We evaluated the relative sensitivity for HPV detection of self-collection compared with practitioner-collected cervical specimens in the context of the Australian National Cervical Screening Program (NCSP).

    STUDY DESIGN: 303 women aged ≥18 years attending a single tertiary referral centre took their own sample using a flocked-swab, and then had a practitioner-collected sample taken at colposcopy. All samples were tested at a single laboratory on the six PCR-based HPV assays which can be utilised in the NCSP; Roche cobas 4800 and cobas, Abbott RealTime, BD Onclarity, Cepheid Xpert, and Seegene Anyplex.

    RESULTS: HPV16/18 results had high observed agreement between self- and practitioner-collected samples on all assays (range: 0.94-0.99), with good agreement for non-HPV16/18 oncogenic HPV types (range: 0.64-0.73).

    CONCLUSIONS: Self-collection for HPV-based cervical screening shows good concordance and relative sensitivity when compared to practitionercollected samples across assays in the NCSP.

    Matched MeSH terms: Specimen Handling/methods*
  11. Latiff LA, Rahman SA, Wee WY, Dashti S, Andi Asri AA, Unit NH, et al.
    Asian Pac J Cancer Prev, 2015;16(2):559-64.
    PMID: 25684487
    BACKGROUND: The participation of women in cervical cancer screening in Malaysia is low. Self-sampling might be able to overcome this problem.The aim of this study was to assess the reliability of self-sampling for cervical smear in our country.

    MATERIALS AND METHODS: This cross-sectional study was conducted on 258 community dwelling women from urban and rural settings who participated in health campaigns. In order to reduce the sampling bias, half of the study population performed the self-sampling prior to the physician sampling while the other half performed the self-sampling after the physician sampling, randomly. Acquired samples were assessed for cytological changes as well as HPV DNA detection.

    RESULTS: The mean age of the subjects was 40.4±11.3 years. The prevalence of abnormal cervical changes was 2.7%. High risk and low risk HPV genotypes were found in 4.0% and 2.7% of the subjects, respectively. A substantial agreement was observed between self-sampling and the physician obtained sampling in cytological diagnosis (k=0.62, 95%CI=0.50, 0.74), micro-organism detection (k=0.77, 95%CI=0.66, 0.88) and detection of hormonal status (k=0.75, 95%CI=0.65, 0.85) as well as detection of high risk (k=0.77, 95%CI=0.4, 0.98) and low risk (K=0.77, 95%CI=0.50, 0.92) HPV. Menopausal state was found to be related with 8.39 times more adequate cell specimens for cytology but 0.13 times less adequate cell specimens for virological assessment.

    CONCLUSIONS: This study revealed that self-sampling has a good agreement with physician sampling in detecting HPV genotypes. Self-sampling can serve as a tool in HPV screening while it may be useful in detecting cytological abnormalities in Malaysia.

    Matched MeSH terms: Specimen Handling/methods*
  12. Ma'som M, Bhoo-Pathy N, Nasir NH, Bellinson J, Subramaniam S, Ma Y, et al.
    BMJ Open, 2016 08 04;6(8):e011022.
    PMID: 27491667 DOI: 10.1136/bmjopen-2015-011022
    OBJECTIVE: The objective of this study was to determine the attitudes and acceptability of self-administered cervicovaginal sampling compared with conventional physician-acquired Papanicolaou (Pap) smear among multiethnic Malaysian women.

    METHOD: A cross-sectional study was carried out via interviewer-administered surveys from August 2013 through August 2015 at five government-run, urban health clinics in the state of Selangor. Subjects were participants from an ongoing community-based human papillomavirus (HPV) prevalence study who answered a standard questionnaire before and after self-sampling. The cervicovaginal self-sampling for HPV genotyping was performed using a simple brush ('Just for Me'; Preventive Oncology International, Hong Kong). Detailed data on sociodemographics, previous Pap smear experience, and attitudes towards self-administered cervicovaginal sampling were collected and analysed. Acceptability was inferred using a five-item Likert scale that included six different subjective descriptives: experience, difficulty, convenience, embarrassment, discomfort or pain, and confidence in collecting one's own sample.

    RESULTS: Of the 839 participants, 47.9% were Malays, followed by 30.8% Indians, 18.8% Chinese and 2.5% from other ethnicities. The median age of the participants was 38 years (IQR 30-48). Some 68.2% of participants indicated a preference for self-sampling over the Pap test, with 95% indicating willingness to follow-up a positive result at the hospital. Age, ethnicity and previous Pap test experience were significant independent factors associated with preference for self-sampling. The older the individual, the less likely they were to prefer self-sampling (adjusted OR 0.94, 95% CI 0.90 to 0.98). The Chinese were less likely to prefer self-sampling (72.6%) than the Malays (85.1%) (adjusted OR 0.57, 95% CI 0.33 to 0.98, p=0.004). Participants who had never undergone a Pap smear were also more likely to prefer self-sampling (88.5%) than women who had undergone a previous Pap (80.9%) (adjusted OR 0.06, 95% CI 0.35 to 0.87).

    CONCLUSIONS: Overall, urban Malaysian women from multiethnic backgrounds found self-sampling to be an acceptable alternative to Pap smear.
    Matched MeSH terms: Specimen Handling/methods*
  13. Rao M, Rashid FA, Sabri FSAH, Jamil NN, Seradja V, Abdullah NA, et al.
    J Med Virol, 2021 Apr;93(4):2461-2466.
    PMID: 33393672 DOI: 10.1002/jmv.26773
    An optimal clinical specimen for accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by minimizing the usage of consumables and reduce hazard exposure to healthcare workers is an urgent priority. The diagnostic performance of SARS-CoV-2 detection between healthcare worker-collected nasopharyngeal and oropharyngeal (NP + OP) swabs and patient performed self-collected random saliva was assessed. Paired NP + OP swabs and random saliva were collected and processed within 48 h of specimen collection from two cohort studies which recruited 562 asymptomatic adult candidates. Real-time reverse-transcription polymerase chain reaction targeting Open reading frame 1a (ORF1a) and nucleocapsid (N) genes was performed and the results were compared. Overall, 65 of 562 (28.1%) candidates tested positive for COVID-19 based on random saliva, NP + OP swabs, or both testing techniques. The detection rate of SARS-CoV-2 was higher in random saliva compared to NP + OP testing (92.3%; 60/65 vs. 73.8%; 48/65; p specimens. Our findings demonstrate that random saliva is an alternative diagnostic specimen for the detection of SARS-CoV-2. Self-collected random oropharyngeal saliva is a valuable specimen that provides accurate SARS-CoV-2 surveillance testing of a community.
    Matched MeSH terms: Specimen Handling/methods
  14. Ng ML, Sazali BS, Khalid BA
    Ann. Clin. Biochem., 1991 Nov;28 ( Pt 6):613-7.
    PMID: 1776812
    A filter method for collection and storage of capillary blood spots for glycated haemoglobin (gHb) has been developed. Glass fibre filters (GFB) impregnated with 0.8 M boric acid were used to collect and store capillary blood. Haemoglobin from the dried blood spots was eluted into water and determined by Drabkin's method, while gHb in the eluates was determined by the microcolorimetric method. The intraassay coefficients of variation (CVs) were 4.5, 4.5 and 3.1% at 882, 1101 and 1704 pmol HMF/mg Hb, respectively. The corresponding inter-assay CVs were 8.6, 8.6 and 6.3%, respectively. A total of 63 paired capillary and venous blood samples were measured by both the direct and GFB method. The GFB method showed excellent correlation with the direct method (r = 0.948 and r = 0.994) after 7 and 14 days' storage at room temperature. The GFB method will enable prior collection and postage of blood samples by patients.
    Matched MeSH terms: Specimen Handling/methods*
  15. Latiff LA, Ibrahim Z, Pei CP, Rahman SA, Akhtari-Zavare M
    Asian Pac J Cancer Prev, 2015;16(18):8495-501.
    PMID: 26745108
    PURPOSE: This study was conducted to assess the agreement and differences between cervical self-sampling with a Kato device (KSSD) and gynecologist sampling for Pap cytology and human papillomavirus DNA (HPV DNA) detection.

    MATERIALS AND METHODS: Women underwent self-sampling followed by gynecologist sampling during screening at two primary health clinics. Pap cytology of cervical specimens was evaluated for specimen adequacy, presence of endocervical cells or transformation zone cells and cytological interpretation for cells abnormalities. Cervical specimens were also extracted and tested for HPV DNA detection. Positive HPV smears underwent gene sequencing and HPV genotyping by referring to the online NCBI gene bank. Results were compared between samplings by Kappa agreement and McNemar test.

    RESULTS: For Pap specimen adequacy, KSSD showed 100% agreement with gynecologist sampling but had only 32.3% agreement for presence of endocervical cells. Both sampling showed 100% agreement with only 1 case detected HSIL favouring CIN2 for cytology result. HPV DNA detection showed 86.2%agreement (K=0.64, 95% CI 0.524-0.756, p=0.001) between samplings. KSSD and gynaecologist sampling identified high risk HPV in 17.3% and 23.9% respectively (p= 0.014).

    CONCLUSION: The self-sampling using Kato device can serve as a tool in Pap cytology and HPV DNA detection in low resource settings in Malaysia. Self-sampling devices such as KSSD can be used as an alternative technique to gynaecologist sampling for cervical cancer screening among rural populations in Malaysia.

    Matched MeSH terms: Specimen Handling/methods*
  16. Asplund M, Kjartansdóttir KR, Mollerup S, Vinner L, Fridholm H, Herrera JAR, et al.
    Clin Microbiol Infect, 2019 Oct;25(10):1277-1285.
    PMID: 31059795 DOI: 10.1016/j.cmi.2019.04.028
    OBJECTIVES: Sample preparation for high-throughput sequencing (HTS) includes treatment with various laboratory components, potentially carrying viral nucleic acids, the extent of which has not been thoroughly investigated. Our aim was to systematically examine a diverse repertoire of laboratory components used to prepare samples for HTS in order to identify contaminating viral sequences.

    METHODS: A total of 322 samples of mainly human origin were analysed using eight protocols, applying a wide variety of laboratory components. Several samples (60% of human specimens) were processed using different protocols. In total, 712 sequencing libraries were investigated for viral sequence contamination.

    RESULTS: Among sequences showing similarity to viruses, 493 were significantly associated with the use of laboratory components. Each of these viral sequences had sporadic appearance, only being identified in a subset of the samples treated with the linked laboratory component, and some were not identified in the non-template control samples. Remarkably, more than 65% of all viral sequences identified were within viral clusters linked to the use of laboratory components.

    CONCLUSIONS: We show that high prevalence of contaminating viral sequences can be expected in HTS-based virome data and provide an extensive list of novel contaminating viral sequences that can be used for evaluation of viral findings in future virome and metagenome studies. Moreover, we show that detection can be problematic due to stochastic appearance and limited non-template controls. Although the exact origin of these viral sequences requires further research, our results support laboratory-component-linked viral sequence contamination of both biological and synthetic origin.

    Matched MeSH terms: Specimen Handling/methods*
  17. Chua AL, Elina HT, Lim BH, Yean CY, Ravichandran M, Lalitha P
    J Med Microbiol, 2011 Apr;60(Pt 4):481-485.
    PMID: 21183596 DOI: 10.1099/jmm.0.027433-0
    Vibrio cholerae has caused severe outbreaks of cholera worldwide with thousands of recorded deaths annually. Molecular diagnosis for cholera has become increasingly important for rapid detection of cholera as the conventional methods are time-consuming and labour intensive. However, traditional PCR tests still require cold-chain transportation and storage as well as trained personnel to perform, which makes them user-unfriendly. The aim of this study was to develop a thermostabilized triplex PCR test for cholera which is in a ready-to-use form and requires no cold chain. The PCR test specifically detects both toxigenic and non-toxigenic strains of V. cholerae based on the cholera toxin A (ctxA) and outer-membrane lipoprotein (lolB) genes. The thermostabilized triplex PCR also incorporates an internal amplification control that helps to check for PCR inhibitors in samples. PCR reagents and the specific primers were lyophilized into a pellet form in the presence of trehalose, which acts as an enzyme stabilizer. The triplex PCR was validated with 174 bacteria-spiked stool specimens and was found to be 100 % sensitive and specific. The stability of the thermostabilized PCR was evaluated using the Q10 method and it was found to be stable for approximately 7 months at 24 °C. The limit of detection of the thermostabilized triplex PCR assay was 2×10(4) c.f.u. at the bacterial cell level and 100 pg DNA at the genomic DNA level, comparable to conventional PCR methods. In conclusion, a rapid thermostabilized triplex PCR assay was developed for detecting toxigenic and non-toxigenic V. cholerae which requires minimal pipetting steps and is cold chain-free.
    Matched MeSH terms: Specimen Handling/methods
  18. Katayon S, Noor MJ, Asma M, Ghani LA, Thamer AM, Azni I, et al.
    Bioresour Technol, 2006 Sep;97(13):1455-60.
    PMID: 16213137
    Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.
    Matched MeSH terms: Specimen Handling/methods*
  19. Ooi MH, Solomon T, Podin Y, Mohan A, Akin W, Yusuf MA, et al.
    J Clin Microbiol, 2007 Jun;45(6):1858-66.
    PMID: 17446325
    Human enterovirus 71 and coxsackievirus A16 are important causes of hand-foot-and-mouth disease (HFMD). Like other enteroviruses, they can be isolated from a range of sterile and nonsterile sites, but which clinical sample, or combination of samples, is the most useful for laboratory diagnosis of HFMD is not clear. We attempted virus culture for 2,916 samples from 628 of 725 children with HFMD studied over a 3 1/2-year period, which included two large outbreaks. Overall, throat swabs were the single most useful specimen, being positive for any enterovirus for 288 (49%) of 592 patients with a full set of samples. Vesicle swabs were positive for 169 (48%) of 333 patients with vesicles, the yield being greater if two or more vesicles were swabbed. The combination of throat plus vesicle swabs enabled the identification of virus for 224 (67%) of the 333 patients with vesicles; for this patient group, just 27 (8%) extra patients were diagnosed when rectal and ulcer swabs were added. Of 259 patients without vesicles, use of the combination of throat plus rectal swab identified virus for 138 (53%). For 60 patients, virus was isolated from both vesicle and rectal swabs, but for 12 (20%) of these, the isolates differed. Such discordance occurred for just 11 (10%) of 112 patients with virus isolated from vesicle and throat swabs. During large HFMD outbreaks, we suggest collecting swabs from the throat plus one other site: vesicles, if these are present (at least two should be swabbed), or the rectum if there are no vesicles. Vesicle swabs give a high diagnostic yield, with the added advantage of being from a sterile site.
    Matched MeSH terms: Specimen Handling/methods
  20. Jamail M, Andrew K, Junaidi D, Krishnan AK, Faizal M, Rahmah N
    Trop Med Int Health, 2005 Jan;10(1):99-104.
    PMID: 15655019
    We conducted a field study of a rapid test (Brugia Rapid) for detection of Brugia malayi infection to validate its sensitivity and specificity under operational conditions. Seven districts in the state of Sarawak, Malaysia, which are endemic for brugian filariasis, were used to determine the test sensitivity. Determination of specificity was performed in another state in Malaysia (Bachok, Kelantan) which is non-endemic for filariasis but endemic for soil-transmitted helminths. In Sarawak both the rapid test and thick blood smear preparation were performed in the field. The rapid test was interpreted on site, whereas blood smears were taken to the district health centres for staining and microscopic examination. Sensitivity of Brugia Rapid dipstick as compared with microscopy of thick blood smears was 87% (20/23; 95% CI: 66.4-97.2) whereas the specificity was 100% (512/512). The lower sensitivity of the test in the field than in laboratory evaluations (> or =95%), was probably due to the small number of microfilaraemic individuals, in addition to difficulties in performing the test in remote villages by field personnel. The overall prevalence of brugian filariasis as determined by the dipstick is 9.4% (95% CI: 8.2-0.5) while that determined by microscopy is 0.90% (95% CI: 0.5-1.3) thus the dipstick detected about 10 times more cases than microscopy. Equal percentages of adults and children were found to be positive by the dipstick whereas microscopy showed that the number of infected children was seven times less than infected adults. The rapid dipstick test was useful as a diagnostic tool for mapping and certification phases of the lymphatic filariasis elimination programme in B. malayi-endemic areas.
    Matched MeSH terms: Specimen Handling/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links