Displaying publications 1 - 20 of 120 in total

Abstract:
Sort:
  1. Chung WH, Chiu CK, Wei Chan CY, Kwan MK
    Acta Orthop Traumatol Turc, 2020 Sep;54(5):561-564.
    PMID: 33155569 DOI: 10.5152/j.aott.2020.19144
    Growth hormone secreting pituitary tumor or gigantism has not been previously reported to be associated with rapid progression of scoliosis in the literature. However, there are some reports indicating scoliosis can be worsened by growth hormone therapy in children and adolescents. A 19-year-old boy was referred to our institution for the treatment of a right thoracolumbar scoliosis. The Cobb angle had worsened from 29° to 83° over two years' duration. He attained puberty at the age of 13. He had a previous history of slipped upper femoral epiphysis (SUFE), which was operated in 2015, with no clinical features of gigantism. Preoperative assessment was performed. He was diagnosed with growth hormone secreting pituitary macroadenoma by magnetic resonance imaging with a high serum level of insulin-like growth factor-I (IGF-I). Computed tomography (CT) of the pancreas showed a pancreatic endocrine tumor. The patient was later diagnosed with multiple endocrine neoplasia type 1 (MEN 1). He underwent endoscopic endonasal excision of the pituitary mass and distal pancreatectomy. This case indicates that growth hormone secreting pituitary macroadenoma could result in rapid progression of scoliosis.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  2. Fijasri NH, Muhammad Asri NA, Mohd Shah MS, Abd Samad MR, Omar N
    Afr J Paediatr Surg, 2023;20(3):245-248.
    PMID: 37470566 DOI: 10.4103/ajps.AJPS_10_21
    Congenital pulmonary airway malformation (CPAM) together with oesophageal atresia and tracheoesophageal fistula (TOF) is a very rare condition in neonates. We presented a case of an infant with Gross type C oesophageal atresia with TOF coexisting with Stocker Type III CPAM in our centre. It is interesting to know that TOF associated with type III CPAM has never been reported in the literature. The child was delivered through caesarean section, and because of respiratory distress post-delivery, endotracheal intubation was carried out immediately. CPAM was diagnosed by a suspicious finding from the initial chest X-ray and the diagnosis was confirmed through computed tomography scan of the chest. The patient was initially stabilised in a neonatal intensive care unit (NICU), and after the successful ligation of fistula and surgical repair of TOF, lung recruitment was started by high flow oscillatory ventilation. The patient recovered well without complications and able to maintain good saturation without oxygen support through the stay in the neonatal unit. Early recognition of this rare association is essential for immediate transfer to NICU, the intervention of any early life-threatening complications, and for vigilant monitoring in the postoperative period.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  3. Thong JF, Low D, Tham A, Liew C, Tan TY, Yuen HW
    Am J Otolaryngol, 2017 Mar-Apr;38(2):218-221.
    PMID: 28139318 DOI: 10.1016/j.amjoto.2017.01.015
    OBJECTIVE: Recent studies demonstrated the utility of high-resolution computed tomography (HRCT) scans in measuring basal cochlear length and cochlear insertion depths. These studies showed significant variations in the anatomy of the cochlea amongst humans. The aim of our study was to investigate for gender and racial variations in the basal turn length of the human cochlea in an Asian population.

    METHOD: HRCT temporal bone data from year 1997 till 2012 of patients with normally developed cochleae who reported with otologic disease was obtained. Reconstruction of the full basal turn was performed for both ears. The largest distance from the midpoint of the round window, through the midmodiolar axis, to the lateral wall was measured (distance A). Length of the lateral wall of the cochlea to the first turn (360°) was calculated and statistically analyzed.

    RESULTS: HRCT temporal bone data from 161 patients was initially obtained. Four patients were subsequently excluded from the study as they were of various other racial groups. Study group therefore comprised of 157 patients (314 cochleae). Mean distance A was statistically different between the two sides of the ear (right 9.09mm; left 9.06mm; p=0.0069). Significant gender and racial differences were also found. Mean distance A was 9.17mm in males and 8.97mm in females (p=0.0016). The racial groups were Chinese (39%), Malay (38%) and Indian (22%). Between racial groups, mean distance A was 9.11mm (Chinese), 9.11mm (Malays) and 8.99mm (Indians). The mean basal turn lengths ranged from 19.71mm to 25.09mm. With gender factored in, significant variation in mean basal turn lengths was found across all three racial groups (p=0.04).

    CONCLUSION: The view of the basal turn of the cochlea from HRCT is simple to obtain and reproducible. This study found significant differences in basal cochlear length amongst male and female Asian patients, as well as amongst various racial groups. This has implications for cochlear electrode insertion as well as electrode array design.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  4. Abdullah A, Mahmud MR, Maimunah A, Zulfiqar MA, Saim L, Mazlan R
    Ann Acad Med Singap, 2003 Jul;32(4):442-5.
    PMID: 12968546
    INTRODUCTION: Accurate preoperative imaging of the temporal bone in patients receiving cochlear implants is important. High resolution computed tomography (HRCT) and magnetic resonance (MR) imaging are the 2 preoperative imaging modalities that provide critical information on abnormalities of the otic capsule, pneumatisation of the mastoid, middle ear abnormalities, cochlear ducts patency and presence of cochlear nerve.

    MATERIALS AND METHODS: The HRCT and MR imaging in 46 cochlear implant patients in our department were reviewed.

    RESULTS: Majority of our patients [34 patients (73.9%)] showed normal HRCT of the temporal bone; 5 (10.9%) patients had labyrinthitis ossificans, 2 (4.3%) had Mondini's abnormality and 2 (4.3%) had middle ear effusion. One patient each had high jugular bulb, hypoplasia of the internal auditory canal and single cochlear cavity, respectively.

    CONCLUSION: The above findings contribute significantly to our surgical decisions regarding candidacy for surgery, side selection and surgical technique in cochlear implantation.

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  5. Pasha MF, Hong KS, Rajeswari M
    PMID: 22255503 DOI: 10.1109/IEMBS.2011.6091280
    Automating the detection of lesions in liver CT scans requires a high performance and robust solution. With CT-scan start to become the norm in emergency department, the need for a fast and efficient liver lesions detection method is arising. In this paper, we propose a fast and evolvable method to profile the features of pre-segmented healthy liver and use it to detect the presence of liver lesions in emergency scenario. Our preliminary experiment with the MICCAI 2007 grand challenge datasets shows promising results of a fast training time, ability to evolve the produced healthy liver profiles, and accurate detection of the liver lesions. Lastly, the future work directions are also presented.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  6. Rais NNM, Bradley DA, Hashim A, Osman ND, Noor NM
    Appl Radiat Isot, 2019 Nov;153:108810.
    PMID: 31351374 DOI: 10.1016/j.apradiso.2019.108810
    For a range of doses familiarly incurred in computed tomography (CT), study is made of the performance of Germanium (Ge)-doped fibre dosimeters formed into cylindrical and flat shapes. Indigenously fabricated 2.3 mol% and 6 mol% Ge-dopant concentration preforms have been used to produce flat- and cylindrical-fibres (FF and CF) of various size and diameters; an additional 4 mol% Ge-doped commercial fibre with a core diameter of 50 μm has also been used. The key characteristics examined include the linearity index f(d), dose sensitivity and minimum detectable dose (MDD), the performance of the fibres being compared against that of lithium-fluoride based TLD-100 thermoluminescence (TL) dosimeters. For doses in the range 2-40 milligray (mGy), delivered at constant potential of 120 kilovoltage (kV), both the fabricated and commercial fibres demonstrate supralinear behaviours at doses  4 mGy. In terms of dose sensitivity, all of the fibres show superior TL sensitivity when compared against TLD-100, the 2.3 mol% and 6 mol% Ge-doped FF demonstrating the greatest TL sensitivity at 84 and 87 times that of TLD-100. The TL yields for the novel Ge-doped silica glass render them appealing for use within the present medical imaging dose range, offering linearity at high sensitivity down to less than 2 mGy.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  7. Tan VP, Macdonald HM, Gabel L, McKay HA
    Arch Osteoporos, 2018 Mar 20;13(1):31.
    PMID: 29556801 DOI: 10.1007/s11657-018-0441-9
    Physical activity is essential for optimal bone strength accrual, but we know little about interactions between physical activity, sedentary time, and bone outcomes in older adolescents. Physical activity (by accelerometer and self-report) positively predicted bone strength and the distal and midshaft tibia in 15-year-old boys and girls. Lean body mass mediated the relationship between physical activity and bone strength in adolescents.

    PURPOSE: To examine the influence of physical activity (PA) and sedentary time on bone strength, structure, and density in older adolescents.

    METHODS: We used peripheral quantitative computed tomography to estimate bone strength at the distal tibia (8% site; bone strength index, BSI) and tibial midshaft (50% site; polar strength strain index, SSIp) in adolescent boys (n = 86; 15.3 ± 0.4 years) and girls (n = 106; 15.3 ± 0.4 years). Using accelerometers (GT1M, Actigraph), we measured moderate-to-vigorous PA (MVPAAccel), vigorous PA (VPAAccel), and sedentary time in addition to self-reported MVPA (MVPAPAQ-A) and impact PA (ImpactPAPAQ-A). We examined relations between PA and sedentary time and bone outcomes, adjusting for ethnicity, maturity, tibial length, and total body lean mass.

    RESULTS: At the distal tibia, MVPAAccel and VPAAccel positively predicted BSI (explained 6-7% of the variance, p 

    Matched MeSH terms: Tomography, X-Ray Computed/methods
  8. Hashim N, Jamalludin Z, Ung NM, Ho GF, Malik RA, Phua VC
    Asian Pac J Cancer Prev, 2014;15(13):5259-64.
    PMID: 25040985
    BACKGROUND: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT).

    MATERIALS AND METHODS: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6 Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose (DMax) to rectum was the highest recorded dose at one of these five points. Using the HDR plus 2.6 brachytherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded (D2cc) for all individual fractions. The mean D2cc of rectum was compared to the means of ICRU rectal point and rectal DMax using the Student's t-test. The mean D2cc of bladder was compared with the mean ICRU bladder point using the same statistical test .The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (α/β value of 10 Gy for target, 3 Gy for organs at risk).

    RESULTS: The total prescribed dose was 77.5 Gy α/β10. The mean dose to the rectum was 4.58 ± 1.22 Gy for D 2cc, 3.76 ± 0.65 Gy at D ICRU and 4.75 ± 1.01 Gy at DMax. The mean rectal D 2cc dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48 -1.19 Gy). The mean EQD2 was 68.52 ± 7.24 Gy α/β3 for D 2cc, 61.71 ± 2.77 Gy α/β3 at D ICRU and 69.24 ± 6.02 Gy α/β3 at DMax. The mean ratio of D 2cc rectum to D ICRU rectum was 1.25 and the mean ratio of D 2cc rectum to DMax rectum was 0.98 for all individual fractions. The mean dose to the bladder was 6.00 ± 1.90 Gy for D 2cc and 5.10 ± 2.03 Gy at D ICRU. However, the mean D 2cc dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25 Gy). The mean EQD2 was 81.85 ± 13.03 Gy α/β3 for D 2cc and 74.11 ± 19.39 Gy α/β3 at D ICRU. The mean ratio of D 2cc bladder to D ICRU bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose.

    CONCLUSIONS: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the D 2cc and rectal DMax for D 2cc. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the D 2cc.

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  9. Saffor A, bin Ramli AR, Ng KH
    Australas Phys Eng Sci Med, 2003 Jun;26(2):39-44.
    PMID: 12956184
    Wavelet-based image coding algorithms (lossy and lossless) use a fixed perfect reconstruction filter-bank built into the algorithm for coding and decoding of images. However, no systematic study has been performed to evaluate the coding performance of wavelet filters on medical images. We evaluated the best types of filters suitable for medical images in providing low bit rate and low computational complexity. In this study a variety of wavelet filters are used to compress and decompress computed tomography (CT) brain and abdomen images. We applied two-dimensional wavelet decomposition, quantization and reconstruction using several families of filter banks to a set of CT images. Discreet Wavelet Transform (DWT), which provides efficient framework of multi-resolution frequency was used. Compression was accomplished by applying threshold values to the wavelet coefficients. The statistical indices such as mean square error (MSE), maximum absolute error (MAE) and peak signal-to-noise ratio (PSNR) were used to quantify the effect of wavelet compression of selected images. The code was written using the wavelet and image processing toolbox of the MATLAB (version 6.1). This results show that no specific wavelet filter performs uniformly better than others except for the case of Daubechies and bi-orthogonal filters which are the best among all. MAE values achieved by these filters were 5 x 10(-14) to 12 x 10(-14) for both CT brain and abdomen images at different decomposition levels. This indicated that using these filters a very small error (approximately 7 x 10(-14)) can be achieved between original and the filtered image. The PSNR values obtained were higher for the brain than the abdomen images. For both the lossy and lossless compression, the 'most appropriate' wavelet filter should be chosen adaptively depending on the statistical properties of the image being coded to achieve higher compression ratio.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  10. Anderson PJ, Yong R, Surman TL, Rajion ZA, Ranjitkar S
    Aust Dent J, 2014 Jun;59 Suppl 1:174-85.
    PMID: 24611727 DOI: 10.1111/adj.12154
    Following the invention of the first computed tomography (CT) scanner in the early 1970s, many innovations in three-dimensional (3D) diagnostic imaging technology have occurred, leading to a wide range of applications in craniofacial clinical practice and research. Three-dimensional image analysis provides superior and more detailed information compared with conventional plain two-dimensional (2D) radiography, with the added benefit of 3D printing for preoperative treatment planning and regenerative therapy. Current state-of-the-art multidetector CT (MDCT), also known as medical CT, has an important role in the diagnosis and management of craniofacial injuries and pathology. Three-dimensional cone beam CT (CBCT), pioneered in the 1990s, is gaining increasing popularity in dental and craniofacial clinical practice because of its faster image acquisition at a lower radiation dose, but sound guidelines are needed to ensure its optimal clinical use. Recent innovations in micro-computed tomography (micro-CT) have revolutionized craniofacial biology research by enabling higher resolution scanning of teeth beyond the capabilities of MDCT and CBCT, presenting new prospects for translational clinical research. Even after four decades of refinement, CT technology continues to advance and broaden the horizons of craniofacial clinical practice and phenomics research.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  11. Khajotia RR, Raman S
    Aust Fam Physician, 2017 Nov;46(11):845-846.
    PMID: 29101921
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  12. Choo CS, Wan Abdul Rahman WF, Jaafar H, Ramli RR
    BMJ Case Rep, 2019 Mar 09;12(3).
    PMID: 30852518 DOI: 10.1136/bcr-2018-228969
    Chondrosarcoma (CS) is a malignant tumour of long and flat bone characterised by the formation of cartilage. Mesenchymal chondrosarcoma (MCS) is a rare subtype of CS that is more aggressive and may lead to erroneous diagnosis in a limited biopsy. The diagnosis is mainly based on the histopathological appearance of biphasic pattern of undifferentiated small round cells separated by islands of well-differentiated hyaline cartilage. We report a case of 13-year-old boy who initially presented with gum swelling and the biopsy result suggested a benign fibrous lesion. Following an extensive lesion shown in radiologic findings, the tumour excision was done and finally was diagnosed as an MCS of the maxilla. The patient was given postoperative chemotherapy (EURO-EWING 99 regimen), and now on regular follow-up for monitoring of local recurrence or tumour metastasis.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  13. Ng CY, Hayati F, Nadarajan C
    BMJ Case Rep, 2020 Sep 09;13(9).
    PMID: 32912885 DOI: 10.1136/bcr-2020-235174
    Malignant melanoma is cancer of the skin which commonly metastasises to the stomach. There have been no reported cases of emphysematous gastritis secondary to metastasis of malignant melanomas, to date. However, a 61-year-old woman with metastatic malignant melanoma of the left great toe presented to us with symptoms of severe left hypochondrium pain associated with high-grade fever, gross abdominal distension and recurrent vomiting. Two months earlier, metastasis was observed to have spread to the stomach and inguinal lymph nodes. At this stage, the patient opted for traditional medication instead of definitive surgery and chemotherapy. Radiological imaging revealed an emphysematous change to the stomach which was radiologically consistent with gastric malignant melanoma. Unfortunately, the patient succumbed to this rare condition.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  14. Rasmussen LD, Pedersen C, Madsen HD, Laursen CB
    BMJ Case Rep, 2017 Nov 29;2017.
    PMID: 29191821 DOI: 10.1136/bcr-2017-221025
    A 36-year-old Danish man, living in Asia, was diagnosed with Pneumocystis pneumonia (PCP) and HIV in 2013 (CD4+ count: 6 cells/µL; viral load: 518 000 copies/mL). He initiated combination antiretroviral therapy. Later that year, he was also diagnosed with granulomatosis with polyangiitis and was treated with prednisolone. Despite complete viral suppression and increasing CD4+ count (162 cells/µL), he was readmitted with PCP in April 2015. Subsequently, he returned to Denmark (CD4+ count: 80 cells/µL, viral suppression). Over the following months, he developed progressive dyspnoea. Lung function tests demonstrated severely reduced lung capacity with an obstructive pattern and a moderately reduced diffusion capacity. High resolution computer tomography revealed minor areas with tree-in-bud pattern and no signs of air trapping on expiratory views. Lung biopsy showed lymphocytic infiltration surrounding the bronchioles with sparing of the alveolar septa. He was diagnosed with follicular bronchiolitis. The patient spontaneously recovered along with an improvement of the immune system.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  15. Ong SCL, Mohaidin N
    BMJ Case Rep, 2018 Sep 30;2018.
    PMID: 30275028 DOI: 10.1136/bcr-2018-227121
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  16. Lai C, Mohammad N, Hassan TM, Abdul Hamid MF
    BMJ Case Rep, 2017 Sep 11;2017.
    PMID: 28893806 DOI: 10.1136/bcr-2017-221239
    This case series reviews two cases of elderly patients who presented with fever, cough and shortness of breath. Clinical examinations and initial chest radiographs confirmed unilateral pleural effusion. Thoracenteses were consistent with exudative pleural effusion. We commenced intravenous antibiotics treating for parapneumonic effusions. The first case showed persistent effusion despite drainage, and the second case had a little aspirate from pleural tapping. Subsequent ultrasound of the thorax showed multiloculated effusions. We made the decisions for intrapleural fibrinolytic therapy using low-dose alteplase 2.5 mg each time, in view of the elderly patient as sacrosanct for risk of bleeding. Furthermore, DNase was not used, as it is not yet available in our setting. Both of our patients had good clinical and radiological outcomes, without the need for surgical interventions.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  17. Sim CY, Khoo CS, Mustafar R, Chai JN
    Balkan Med J, 2021 01;38(1):55-56.
    PMID: 32720494 DOI: 10.4274/balkanmedj.galenos.2020.2020.5.208
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  18. Chuah YY, Lee YY, Shih CA
    Br J Hosp Med (Lond), 2017 Aug 02;78(8):474.
    PMID: 28783396 DOI: 10.12968/hmed.2017.78.8.474
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  19. Dong X, Xu S, Liu Y, Wang A, Saripan MI, Li L, et al.
    Cancer Imaging, 2020 Aug 01;20(1):53.
    PMID: 32738913 DOI: 10.1186/s40644-020-00331-0
    BACKGROUND: Convolutional neural networks (CNNs) have been extensively applied to two-dimensional (2D) medical image segmentation, yielding excellent performance. However, their application to three-dimensional (3D) nodule segmentation remains a challenge.

    METHODS: In this study, we propose a multi-view secondary input residual (MV-SIR) convolutional neural network model for 3D lung nodule segmentation using the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset of chest computed tomography (CT) images. Lung nodule cubes are prepared from the sample CT images. Further, from the axial, coronal, and sagittal perspectives, multi-view patches are generated with randomly selected voxels in the lung nodule cubes as centers. Our model consists of six submodels, which enable learning of 3D lung nodules sliced into three views of features; each submodel extracts voxel heterogeneity and shape heterogeneity features. We convert the segmentation of 3D lung nodules into voxel classification by inputting the multi-view patches into the model and determine whether the voxel points belong to the nodule. The structure of the secondary input residual submodel comprises a residual block followed by a secondary input module. We integrate the six submodels to classify whether voxel points belong to nodules, and then reconstruct the segmentation image.

    RESULTS: The results of tests conducted using our model and comparison with other existing CNN models indicate that the MV-SIR model achieves excellent results in the 3D segmentation of pulmonary nodules, with a Dice coefficient of 0.926 and an average surface distance of 0.072.

    CONCLUSION: our MV-SIR model can accurately perform 3D segmentation of lung nodules with the same segmentation accuracy as the U-net model.

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  20. Lee YJ, Zakaria R, Manaf ZA, Mohamed Z, Lee YY
    Chin Med J (Engl), 2013;126(11):2049-53.
    PMID: 23769556
    There is increasing evidence that CT pulmonary arteriography and venography allow a better diagnostic yield for deep vein thrombosis (DVT) in suspected acute pulmonary embolism (PE). The aim was to investigate the value for using such an approach in a multiracial Asian population.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links