Displaying all 4 publications

Abstract:
Sort:
  1. Ismail A, Chen HC, Faye I, Tang TB
    Sci Rep, 2020 09 28;10(1):15829.
    PMID: 32985560 DOI: 10.1038/s41598-020-72556-9
    Real-time impairment of ocular blood flow (OBF) under common carotid artery stenosis (CCAS) has not been ascertained. We aimed to longitudinally assess the impact of CCAS on OBF using a rabbit model. About 75% stenosis was created by tying the common carotid artery with a plastic mandrel using a nylon suture. The plastic mandrel was gently removed, leaving a ligature. Neurological and behavioral assessments were recorded as the clinical indicator of stroke severity. With laser speckle flowgraphy, the pulse waveform parameters namely mean blur rate (MBR), blowout score (BOS), blowout time (BOT), rising rate, S1-area, falling rate (FR), S2-area, flow acceleration index (FAI), acceleration time index, resistive index (RI) and the difference between the maximum and minimum values of MBR (AC) were assessed in overall, vessel, and tissue regions of the optic nerve head (ONH). Longitudinally, BOS significantly increased until day 19 post-surgery, whereas FAI, RI, and AC significantly decreased. Beyond day 19, BOS, BOT, FR, FAI, RI, and AC significantly decreased. We defined two stages representing impaired vessel conditions, namely the vessel resistance phase, where BOS increases and FAI, RI, and AC decrease, and the vessel elasticity phase where BOS, BOT, FR, FAI, RI and AC decrease. These stages provide information about atherosclerosis, assessable non-invasively through the eye.
    Matched MeSH terms: Eye/blood supply*
  2. Bhatti MS, Tang TB, Chen HC
    Sci Rep, 2018 04 09;8(1):5713.
    PMID: 29632320 DOI: 10.1038/s41598-018-24141-4
    In this study, we reported a new technique based on laser speckle flowgraphy to record the ocular blood flow in rabbits under deep anesthesia, and proposed parameters to characterize retinal ischemia. We applied the proposed technique to study the correlation of blood flow between the eyes of normal non-anesthetized animals, and to characterize the occlusion of the internal carotid artery (ICA) and external carotid artery (ECA). We established a correlation in blood flow between the eyes of non-anesthetized animals, and derived two new parameters, namely, the laterality index and vascular perfusion estimate (VPE). Our experimental results from 16 eyes (of 13 New Zealand white rabbits) showed a reduction in ocular blood flow with a significant decrease in the VPE after the occlusion of the ECA (p blood flow was observed with the occlusion of the ICA. In conclusion, we demonstrated a means for the real-time measurement of the ocular blood flow in rabbits under deep anesthesia by using laser speckle flowgraphy and the VPE as an indicator of successful occlusion. The proposed technique might be applicable in quantifying the efficacy of new drugs and interventions for the treatment of retinal ischemia.
    Matched MeSH terms: Eye/blood supply*
  3. Bhatti MS, Tang TB, Laude A
    PLoS One, 2017;12(7):e0181512.
    PMID: 28742142 DOI: 10.1371/journal.pone.0181512
    The water-drinking test (WDT) is a provocative test used in glaucoma research to assess the effects of elevated intraocular pressure (IOP). Defective autoregulation due to changes in perfusion pressure may play a role in the pathophysiology of several ocular diseases. This study aims to examine the effects of WDT on ocular blood flow (in the form of pulse waveform parameters obtained using laser speckle flowgraphy) to gain insight into the physiology of ocular blood flow and its autoregulation in healthy individuals. Changes in pulse waveform parameters of mean blur rate (MBR) in the entire optic nerve head (ONH), the vasculature of the ONH, the tissue area of the ONH, and the avascular tissue area located outside of the ONH were monitored over time. Significant increases in the falling rate of MBR over the entire ONH and its tissue area and decreases in blowout time (BOT) of the tissue area were observed only at 10 minutes after water intake. Significant increases in the skew of the waveform and the falling rate were observed in the vasculature of the ONH at 40 and 50 minutes after water intake, respectively. In the avascular region of the choroid, the average MBR increased significantly up to 30 minutes after water intake. Furthermore, the rising rate in this region increased significantly at 20 and 40 minutes, and the falling rate and acceleration-time index were both significantly increased at 40 minutes after water intake. Our results indicate the presence of effective autoregulation of blood flow at the ONH after WDT. However, in the choroidal region, outside of the ONH, effective autoregulation was not observed until 30 minutes after water intake in healthy study participants. These pulse waveform parameters could potentially be used in the diagnosis and/or monitoring of patients with glaucoma.
    Matched MeSH terms: Eye/blood supply*
  4. Rohana AR, Rosli MK, Nik Rizal NY, Shatriah I, Wan Hazabbah WH
    Orbit, 2008;27(3):215-7.
    PMID: 18569833 DOI: 10.1080/01676830802009754
    We were presented with a teenage female who developed superior ophthalmic vein thrombosis and cavernous sinus thrombophlebitis after a 1-week history of a single acne-like lesion or furuncle at the anterior tip of the nose. She was managed aggressively with heparin and intravenous antibiotic. Signs and symptoms improved after 2 weeks of treatment, and she was discharged with an anticoagulant.
    Matched MeSH terms: Eye/blood supply*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links