Abstract:
Sort:
  1. Yvonne-Tee GB, Rasool AH, Halim AS, Rahman AR
    J Pharmacol Toxicol Methods, 2005 Sep-Oct;52(2):286-92.
    PMID: 16125628
    Postocclusive reactive hyperemia in forearm skin is a commonly used model for studying microvascular reactivity function, particularly in the assessment of vascular effect of topically applied pharmacological substances. In this study, we investigated the reproducibility of several different laser-Doppler-derived parameters in the measurement of postocclusive reactive hyperemia at forearm skin in healthy subjects.
    Matched MeSH terms: Laser-Doppler Flowmetry/adverse effects; Laser-Doppler Flowmetry/methods*
  2. Tayyari F, Yusof F, Vymyslicky M, Tan O, Huang D, Flanagan JG, et al.
    Invest Ophthalmol Vis Sci, 2014 Dec;55(12):7716-25.
    PMID: 25335983 DOI: 10.1167/iovs.14-14430
    The purpose of this study was to determine the within-session variability and between-session repeatability of spectral Fourier-domain optical coherence tomography (Doppler FD-OCT) Doppler retinal blood flow measurements in young and elderly subjects.
    Matched MeSH terms: Laser-Doppler Flowmetry/methods*
  3. Al-Tahami BA, Yvonne-Tee GB, Halim AS, Ismail AA, Rasool AH
    Methods Find Exp Clin Pharmacol, 2010 Apr;32(3):181-5.
    PMID: 20448860 DOI: 10.1358/mf.2010.32.3.1423887
    Iontophoresis of acetylcholine (ACh) and sodium nitroprusside (SNP) combined with laser Doppler fluximetry (LDF) is a tool used to determine microvascular endothelial function. Our aim was to study the reproducibility of different parameters of this technique using iontophoresis with low current strength on the forearm skin of healthy subjects. Baseline skin perfusion was done before application of five current pulses with 1 min of current-free interval. Current strength of 0.007 mA, current density of 0.01 mA/cm(2) and charge density of 6 mC/cm(2) were used, along with 1% ACh and 1% SNP. The absolute maximum change in perfusion (max), percent change in perfusion (% change), peak change in perfusion (peak) and area under the curve during iontophoresis (AUC) at the anodal and cathodal leads were recorded. Measurements were performed in three sessions for 2 days. The coefficient of variation (CV) was calculated for each parameter. Among the parameters studied, maximum change in perfusion and peak flux were the most reproducible parameters.
    Matched MeSH terms: Laser-Doppler Flowmetry/methods*
  4. Ahmad Fadzil MH, Ihtatho D, Mohd Affandi A, Hussein SH
    J Med Eng Technol, 2009;33(7):516-24.
    PMID: 19639508 DOI: 10.1080/07434610902744074
    Skin colour is vital information in dermatological diagnosis as it reflects the pathological condition beneath the skin. It is commonly used to indicate the extent of diseases such as psoriasis, which is indicated by the appearance of red plaques. Although there is no cure for psoriasis, there are many treatment modalities to help control the disease. To evaluate treatment efficacy, the current gold standard method, PASI (Psoriasis Area and Severity Index), is used to determine severity of psoriasis lesion. Erythema (redness) is one parameter in PASI and this condition is assessed visually, thus leading to subjective and inconsistent results. Current methods or instruments that assess erythema have limitations, such as being able to measure erythema well for low pigmented skin (fair skin) but not for highly pigmented skin (dark skin) or vice versa. In this work, we proposed an objective assessment of psoriasis erythema for PASI scoring for different (low to highly pigmented) skin types. The colour of psoriasis lesions are initially obtained by using a chromameter giving the values L*, a*, and b* of CIELAB colour space. The L* value is used to classify skin into three categories: low, medium and highly pigmented skin. The lightness difference (DeltaL*), hue difference (Deltah(ab)), chroma (DeltaC*(ab)) between lesions and the surrounding normal skin are calculated and analysed. It is found that the erythema score of a lesion can be distinguished by their Deltah(ab) value within a particular skin type group. References of lesion with different scores are obtained from the selected lesions by two dermatologists. Results based on 38 lesions from 22 patients with various level of skin pigmentation show that PASI erythema score for different skin types i.e. low (fair skin) to highly pigmented (dark skin) skin types can be determined objectively and consistent with dermatology scoring.
    Matched MeSH terms: Laser-Doppler Flowmetry/methods
  5. Bhatti MS, Tang TB, Laude A
    PLoS One, 2017;12(7):e0181512.
    PMID: 28742142 DOI: 10.1371/journal.pone.0181512
    The water-drinking test (WDT) is a provocative test used in glaucoma research to assess the effects of elevated intraocular pressure (IOP). Defective autoregulation due to changes in perfusion pressure may play a role in the pathophysiology of several ocular diseases. This study aims to examine the effects of WDT on ocular blood flow (in the form of pulse waveform parameters obtained using laser speckle flowgraphy) to gain insight into the physiology of ocular blood flow and its autoregulation in healthy individuals. Changes in pulse waveform parameters of mean blur rate (MBR) in the entire optic nerve head (ONH), the vasculature of the ONH, the tissue area of the ONH, and the avascular tissue area located outside of the ONH were monitored over time. Significant increases in the falling rate of MBR over the entire ONH and its tissue area and decreases in blowout time (BOT) of the tissue area were observed only at 10 minutes after water intake. Significant increases in the skew of the waveform and the falling rate were observed in the vasculature of the ONH at 40 and 50 minutes after water intake, respectively. In the avascular region of the choroid, the average MBR increased significantly up to 30 minutes after water intake. Furthermore, the rising rate in this region increased significantly at 20 and 40 minutes, and the falling rate and acceleration-time index were both significantly increased at 40 minutes after water intake. Our results indicate the presence of effective autoregulation of blood flow at the ONH after WDT. However, in the choroidal region, outside of the ONH, effective autoregulation was not observed until 30 minutes after water intake in healthy study participants. These pulse waveform parameters could potentially be used in the diagnosis and/or monitoring of patients with glaucoma.
    Matched MeSH terms: Laser-Doppler Flowmetry/methods*
  6. Ismail A, Bhatti MS, Faye I, Lu CK, Laude A, Tang TB
    Graefes Arch Clin Exp Ophthalmol, 2018 Sep;256(9):1711-1721.
    PMID: 29876732 DOI: 10.1007/s00417-018-4030-9
    PURPOSE: To evaluate and compare the temporal changes in pulse waveform parameters of ocular blood flow (OBF) between non-habitual and habitual groups due to caffeine intake.

    METHOD: This study was conducted on 19 healthy subjects (non-habitual 8; habitual 11), non-smoking and between 21 and 30 years of age. Using laser speckle flowgraphy (LSFG), three areas of optical nerve head were analyzed which are vessel, tissue, and overall, each with ten pulse waveform parameters, namely mean blur rate (MBR), fluctuation, skew, blowout score (BOS), blowout time (BOT), rising rate, falling rate, flow acceleration index (FAI), acceleration time index (ATI), and resistive index (RI). Two-way mixed ANOVA was used to determine the difference between every two groups where p 

    Matched MeSH terms: Laser-Doppler Flowmetry/methods
  7. Ibrahim NNIN, Rasool AHG
    Skin Res Technol, 2017 Aug;23(3):321-325.
    PMID: 27868242 DOI: 10.1111/srt.12338
    BACKGROUND: Pulse wave analysis (PWA) and laser Doppler fluximetry (LDF) are non-invasive methods of assessing macrovascular endothelial function and microvascular reactivity respectively. The aim of this study was to assess the correlation between macrovascular endothelial function assessed by PWA and microvascular reactivity assessed by LDF.

    METHOD: 297 healthy and non-smoking subjects (159 females, mean age (±SD) 23.56 ± 4.54 years) underwent microvascular reactivity assessment using LDF followed by macrovascular endothelial function assessments using PWA.

    RESULTS: Pearson's correlation showed no correlation between macrovascular endothelial function and microvascular reactivity (r = -0.10, P = 0.12).

    CONCLUSION: There was no significant correlation between macrovascular endothelial function assessed by PWA and microvascular reactivity assessed by LDF in healthy subjects.

    Matched MeSH terms: Laser-Doppler Flowmetry/methods
  8. Tee GB, Rasool AH, Halim AS, Rahman AR
    J Pharmacol Toxicol Methods, 2004 Jul-Aug;50(1):73-8.
    PMID: 15233971 DOI: 10.1016/j.vascn.2004.02.002
    Human postocclusive forearm skin reactive hyperemia is not only a potential means of identifying early signs of cardiovascular diseases, it can also be used in the assessment of local microvascular response to topically applied compounds on skin. The method is not fully characterized. In this study, we investigated the influence of occlusion time on postocclusive forearm skin reactive hyperemia using laser Doppler fluximetry (LDF).
    Matched MeSH terms: Laser-Doppler Flowmetry
  9. Ismail A, Chen HC, Faye I, Tang TB
    Sci Rep, 2020 09 28;10(1):15829.
    PMID: 32985560 DOI: 10.1038/s41598-020-72556-9
    Real-time impairment of ocular blood flow (OBF) under common carotid artery stenosis (CCAS) has not been ascertained. We aimed to longitudinally assess the impact of CCAS on OBF using a rabbit model. About 75% stenosis was created by tying the common carotid artery with a plastic mandrel using a nylon suture. The plastic mandrel was gently removed, leaving a ligature. Neurological and behavioral assessments were recorded as the clinical indicator of stroke severity. With laser speckle flowgraphy, the pulse waveform parameters namely mean blur rate (MBR), blowout score (BOS), blowout time (BOT), rising rate, S1-area, falling rate (FR), S2-area, flow acceleration index (FAI), acceleration time index, resistive index (RI) and the difference between the maximum and minimum values of MBR (AC) were assessed in overall, vessel, and tissue regions of the optic nerve head (ONH). Longitudinally, BOS significantly increased until day 19 post-surgery, whereas FAI, RI, and AC significantly decreased. Beyond day 19, BOS, BOT, FR, FAI, RI, and AC significantly decreased. We defined two stages representing impaired vessel conditions, namely the vessel resistance phase, where BOS increases and FAI, RI, and AC decrease, and the vessel elasticity phase where BOS, BOT, FR, FAI, RI and AC decrease. These stages provide information about atherosclerosis, assessable non-invasively through the eye.
    Matched MeSH terms: Laser-Doppler Flowmetry
  10. Bhatti MS, Tang TB, Chen HC
    Sci Rep, 2018 04 09;8(1):5713.
    PMID: 29632320 DOI: 10.1038/s41598-018-24141-4
    In this study, we reported a new technique based on laser speckle flowgraphy to record the ocular blood flow in rabbits under deep anesthesia, and proposed parameters to characterize retinal ischemia. We applied the proposed technique to study the correlation of blood flow between the eyes of normal non-anesthetized animals, and to characterize the occlusion of the internal carotid artery (ICA) and external carotid artery (ECA). We established a correlation in blood flow between the eyes of non-anesthetized animals, and derived two new parameters, namely, the laterality index and vascular perfusion estimate (VPE). Our experimental results from 16 eyes (of 13 New Zealand white rabbits) showed a reduction in ocular blood flow with a significant decrease in the VPE after the occlusion of the ECA (p laser speckle flowgraphy and the VPE as an indicator of successful occlusion. The proposed technique might be applicable in quantifying the efficacy of new drugs and interventions for the treatment of retinal ischemia.
    Matched MeSH terms: Laser-Doppler Flowmetry
  11. Khoo TL, Halim AS, Zakaria Z, Mat Saad AZ, Wu LY, Lau HY
    J Plast Reconstr Aesthet Surg, 2011 Jun;64(6):e137-45.
    PMID: 20869928 DOI: 10.1016/j.bjps.2010.08.029
    Despite widespread beliefs regarding the use of topical tocotrienol in the prevention of hypertrophic scars, there is very little evidence from well controlled and randomised clinical trials to justify its benefits for surgical scars.
    Matched MeSH terms: Laser-Doppler Flowmetry
  12. Rasool AH, Ghazali DM, Abdullah H, Halim AS, Wong AR
    Microvasc Res, 2009 Sep;78(2):230-4.
    PMID: 19481100 DOI: 10.1016/j.mvr.2009.05.005
    Post occlusive skin reactive hyperemia (PORH) is a tool used to assess microcirculation. Endothelial nitric oxide synthase (eNOS) mediates nitric oxide (NO) production; polymorphism of the eNOS gene may affect response to the PORH process. This study aims to determine whether eNOS G894T gene polymorphism affects response to skin PORH. 230 normotensive male and females between 18 and 40 years participated in this cross-sectional study. 170 subjects were of the homozygous GG genotype, whereas 60 were of the GT genotype. Skin PORH was performed by occlusion of the upper arm at 200 mm Hg for 3 min. Skin perfusion and temperature were monitored before, during and after occlusion release using the laser Doppler fluximetry. There were no significant differences between genotypes in their baseline blood pressure, serum cholesterol, BMI and age. Maximum change in perfusion after occlusion release (PORHmax) for the GG and GT genotypes were not significantly different at 50.15+/-1.29 vs. 47.92+/-2.17 AU; ANCOVA, p=0.351. Peak perfusion (PORHpeak) were also not significantly different between the two genotypes (61.23+/-1.36 vs. 57.72+/-2.32 AU; p=0.169). Minimum baseline perfusion were however higher in the GG compared to the GT genotype (10.83+/-0.29 vs. 9.61+/-0.50, p=0.029). We conclude that microvascular reactivity, assessed by change in perfusion after temporary ischemia was not significantly different between the GG and GT genotypes of the eNOS G894T gene. eNOS 894T allele carriers however, have lower baseline perfusion compared to the homozygous G894 allele carrier.
    Matched MeSH terms: Laser-Doppler Flowmetry
  13. Al-Tahami BA, Ismail AA, Bee YT, Awang SA, Salha Wan Abdul Rani WR, Sanip Z, et al.
    Clin. Hemorheol. Microcirc., 2015;59(4):323-34.
    PMID: 24002121 DOI: 10.3233/CH-131765
    INTRODUCTION: Obesity is associated with impaired microvascular endothelial function. We aimed to determine the effects of orlistat and sibutramine treatment on microvascular endothelial function, anthropometric and lipid profile, blood pressure (BP), and heart rate (HR).
    METHODS: 76 subjects were recruited and randomized to receive orlistat 120 mg three times daily or sibutramine 10 mg daily for 9 months. Baseline weight, BMI, BP, HR and lipid profile were taken. Microvascular endothelial function was assessed using laser Doppler fluximetry and iontophoresis process. Maximum change (max), percent change (% change) and peak flux (peak) in perfusion to acetylcholine (ACh) and sodium nitroprusside (SNP) iontophoresis were used to quantify endothelium dependent and independent vasodilatations.
    RESULTS: 24 subjects in both groups completed the trial. After treatment, weight and BMI were decreased for both groups. AChmax, ACh % change and ACh peak were increased in orlistat-treated group but no difference was observed for sibutramine-treated group. BP and total cholesterol (TC) were reduced for orlistat-treated group. HR was reduced for orlistat-treated group but was increased in sibutramine-treated group.
    CONCLUSION: 9 months treatment with orlistat significantly improved microvascular endothelial function. This was associated with reductions in weight, BMI, BP, HR, TC and low density lipoprotein cholesterol. No effect was seen in microvascular endothelial function with sibutramine.
    KEYWORDS: Microvascular endothelial function; obesity; orlistat; sibutramine
    Matched MeSH terms: Laser-Doppler Flowmetry
  14. Munisamy S, Kamaliah MD, Suhaidarwani AH, Zahiruddin WM, Rasool AH
    J Cardiovasc Med (Hagerstown), 2013 Jun;14(6):466-71.
    PMID: 22964652 DOI: 10.2459/JCM.0b013e3283590d3d
    AIMS: This study aims to compare microvascular endothelial function between vitamin D-deficient and nondeficient groups of patients with diabetic nephropathy. Serum levels of the inflammatory marker high-sensitivity C-reactive protein (hsCRP) were also measured.

    METHODS: This prospective cross-sectional study involved 70 patients with diabetic nephropathy; 40 were categorized into the group with nondeficient serum 25-hydroxyvitamin D levels [25(OH)D >50 nmol/l], whereas 30 patients were categorized to the group with deficient serum 25(OH)D (<50 nmol/l). Microvascular endothelial function was determined using laser Doppler fluximetry and the process of iontophoresis. Acetylcholine and sodium nitroprusside were used to determine endothelium-dependent and independent vasodilatation.

    RESULTS: Mean age of patients was 56.7 ± 3.8 years; 50 were men, whereas 20 were women. Mean serum 25(OH)D in the vitamin D-nondeficient group was 69.4 ± 2.9 nmol/l; the level in the vitamin D-deficient group was 42.1 ± 1.3 nmol/l, P < 0.001. Endothelium-dependent vasodilatation was lower in the vitamin D-deficient group compared with the vitamin D-nondeficient group (23.6 ± 2.7 versus 37.3 ± 3.8 arbitrary units, P = 0.004). No significant differences were observed between the two groups in their hsCRP levels, mean age, estimated glomerular filtration rate, systolic blood pressure (SBP) and diastolic blood pressure (DBP) and glycosylated haemoglobin.

    CONCLUSION: Microvascular endothelial function was significantly reduced in diabetic nephropathy patients with deficient vitamin D levels compared with those with nondeficient levels.

    Matched MeSH terms: Laser-Doppler Flowmetry