METHODS: It was a retrospective study carried out in a Level 1 arthroplasty and trauma centre. 23 patients (17 males, 6 females) with average age of 50.1 years (range, 36-68 years) with displaced acetabular fracture treated with combined incisions and plate-cable systems were included. There were 3 elementary and 18 associated fractures according to Letournel classification. Average follow-up was 23.5 months (range, 12-38.7 months). Mean operation time was 160min (range: 75-320min). Functional scores were evaluated using Harris Hip Score (HHS) whilst reduction was assessed by Matta criteria. Any displacement of reduction, osteoarthritis, heterotopic ossification, and other complications was recorded.
RESULT: 65.2% (15/23) of the patients obtained excellent HHS and 21.7% (5/23) had good HHS. There were 12 anatomical, 6 imperfect, and 5 poor reductions. No displacement was recorded in final follow-up. Complications documented: three lateral femoral cutaneous nerve injuries, two conversions to total hip arthroplasty, three Brooker stage 1 heterotrophic ossification, one pulmonary embolism and one screw irritation. No incidence of wound breakdown, infection and radiological osteoarthritis was reported.
CONCLUSIONS: Imperfect reduction of the anterior column provided clinical outcomes that are as good as total anatomical reduction. This approach minimizes soft tissue damage and reduces perioperative morbidities.