Displaying all 10 publications

Abstract:
Sort:
  1. Marufuzzaman M, Reaz MB, Ali MA, Rahman LF
    Methods Inf Med, 2015;54(3):262-70.
    PMID: 25604028 DOI: 10.3414/ME14-01-0061
    OBJECTIVES: The goal of smart homes is to create an intelligent environment adapting the inhabitants need and assisting the person who needs special care and safety in their daily life. This can be reached by collecting the ADL (activities of daily living) data and further analysis within existing computing elements. In this research, a very recent algorithm named sequence prediction via enhanced episode discovery (SPEED) is modified and in order to improve accuracy time component is included.

    METHODS: The modified SPEED or M-SPEED is a sequence prediction algorithm, which modified the previous SPEED algorithm by using time duration of appliance's ON-OFF states to decide the next state. M-SPEED discovered periodic episodes of inhabitant behavior, trained it with learned episodes, and made decisions based on the obtained knowledge.

    RESULTS: The results showed that M-SPEED achieves 96.8% prediction accuracy, which is better than other time prediction algorithms like PUBS, ALZ with temporal rules and the previous SPEED.

    CONCLUSIONS: Since human behavior shows natural temporal patterns, duration times can be used to predict future events more accurately. This inhabitant activity prediction system will certainly improve the smart homes by ensuring safety and better care for elderly and handicapped people.

    Matched MeSH terms: Monitoring, Ambulatory/instrumentation*
  2. Keikhosrokiani P, Mustaffa N, Zakaria N, Sarwar MI
    PMID: 23138083
    Healthcare for elderly people has become a vital issue. The Wearable Health Monitoring System (WHMS) is used to manage and monitor chronic disease in elderly people, postoperative rehabilitation patients and persons with special needs. Location-aware healthcare is achievable as positioning systems and telecommunications have been developed and have fulfilled the technology needed for this kind of healthcare system. In this paper, the researchers propose a Location-Based Mobile Cardiac Emergency System (LMCES) to track the patient's current location when Emergency Medical Services (EMS) has been activated as well as to locate the nearest healthcare unit for the ambulance service. The location coordinates of the patients can be retrieved by GPS and sent to the healthcare centre using GPRS. The location of the patient, cell ID information will also be transmitted to the LMCES server in order to retrieve the nearest health care unit. For the LMCES, we use Dijkstra's algorithm for selecting the shortest path between the nearest healthcare unit and the patient location in order to facilitate the ambulance's path under critical conditions.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation
  3. Bangash JI, Khan AW, Abdullah AH
    J Med Syst, 2015 Sep;39(9):91.
    PMID: 26242749 DOI: 10.1007/s10916-015-0268-5
    A significant proportion of the worldwide population is of the elderly people living with chronic diseases that result in high health-care cost. To provide continuous health monitoring with minimal health-care cost, Wireless Body Sensor Networks (WBSNs) has been recently emerged as a promising technology. Depending on nature of sensory data, WBSNs might require a high level of Quality of Service (QoS) both in terms of delay and reliability during data reporting phase. In this paper, we propose a data-centric routing for intra WBSNs that adapts the routing strategy in accordance with the nature of data, temperature rise issue of the implanted bio-medical sensors due to electromagnetic wave absorption, and high and dynamic path loss caused by postural movement of human body and in-body wireless communication. We consider the network models both with and without relay nodes in our simulations. Due to the multi-facet routing strategy, the proposed data-centric routing achieves better performance in terms of delay, reliability, temperature rise, and energy consumption when compared with other state-of-the-art.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation*
  4. Simon SK, Seldon HL
    Stud Health Technol Inform, 2012;182:125-32.
    PMID: 23138087
    A target of telehealth is to maintain or improve the health of people outside the normal healthcare infrastructure. A modern paradigm in healthcare, and one which fits perfectly with telehealth, is "person self-monitoring", and this fits with the concept of "personal health record" (PHR). One factor in maintaining health is to monitor physiological parameters; this is of course especially important in people with chronic maladies such as diabetes or heart disease. Parameters to be monitored include blood pressure, pulse rate, temperature, weight, blood glucose, oxygen saturation, electrocardiogram (ECG), etc. So one task within telehealth would be to help monitor an individual's physiological parameters outside of healthcare institutions and store the results in a PHR in a way which is available, comprehensible and beneficial to the individual concerned and to healthcare providers. To date many approaches to this problem have been fragmented - emphasizing only part of the problem - or proprietary and not freely verifiable. We describe a framework to approach this task; it emphasizes the implementation of standards for data acquisition, storage and transmission in order to maximize the compatibility among disparate components, e.g. various PHR systems. Data from mobile biosensors is collected on a smartphone using the IEEE 11073 standard where possible; the data can be stored in a PHR on the phone (using standard formats) or can be converted in real-time into more useful information in the PHR, which is based on the International Classification for Primary Care (ICPC2e). The phone PHR data or information can be uploaded to a central online PHR using either the Wi-Fi or GSM transmission protocol together with the Continuity of Care Record message format (CCR, ASTM E2369).
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation
  5. Gopalai AA, Senanayake SM, Gouwanda D
    IEEE Trans Inf Technol Biomed, 2011 Jul;15(4):608-14.
    PMID: 21478080 DOI: 10.1109/TITB.2011.2140378
    A force-sensing platform (FSP), sensitive to changes of the postural control system was designed. The platform measured effects of postural perturbations in static and dynamic conditions. This paper describes the implementation of an FSP using force-sensing resistors as sensing elements. Real-time qualitative assessment utilized a rainbow color scale to identify areas with high force concentration. Postprocessing of the logged data provided end-users with quantitative measures of postural control. The objective of this research was to establish the feasibility of using an FSP to test and gauge human postural control. Tests were conducted in eye open and eye close states. Readings obtained were tested for repeatability using a one-way analysis of variance test. The platform gauged postural sway by measuring the area of distribution for the weighted center of applied pressure at the foot. A fuzzy clustering algorithm was applied to identify regions of the foot with repetitive pressure concentration. Potential application of the platform in a clinical setting includes monitoring rehabilitation progress of stability dysfunction. The platform functions as a qualitative tool for initial, on-the-spot assessment, and quantitative measure for postacquisition assessment on balance abilities.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation
  6. Almahdi EM, Zaidan AA, Zaidan BB, Alsalem MA, Albahri OS, Albahri AS
    J Med Syst, 2019 May 29;43(7):207.
    PMID: 31144129 DOI: 10.1007/s10916-019-1336-z
    This paper presents comprehensive insights into mobile patient monitoring systems (MPMSs) from evaluation and benchmarking aspects on the basis of two critical directions. The current evaluation criteria of MPMSs based on the architectural components of MPMSs and possible solutions are discussed. This review highlights four serious issues, namely, multiple evaluation criteria, criterion importance, unmeasurable criteria and data variation, in MPMS benchmarking. Multicriteria decision-making (MCDM) analysis techniques are proposed as effective solutions to solve these issues from a methodological aspect. This methodological aspect involves a framework for benchmarking MPMSs on the basis of MCDM to rank available MPMSs and select a suitable one. The benchmarking framework is discussed in four steps. Firstly, pre-processing and identification procedures are presented. Secondly, the procedure of weight calculation based on the best-worst method (BWM) is described. Thirdly, the development of a benchmark framework by using the VIKOR method is introduced. Lastly, the proposed framework is validated.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation
  7. Wafa SW, Aziz NN, Shahril MR, Halib H, Rahim M, Janssen X
    J Trop Pediatr, 2017 04 01;63(2):98-103.
    PMID: 27539845 DOI: 10.1093/tropej/fmw052
    This study describes the patterns of objectively measured sitting, standing and stepping in obese children using the activPALTM and highlights possible differences in sedentary levels and patterns during weekdays and weekends. Sixty-five obese children, aged 9-11 years, were recruited from primary schools in Terengganu, Malaysia. Sitting, standing and stepping were objectively measured using an activPALTM accelerometer over a period of 4-7 days. Obese children spent an average of 69.6% of their day sitting/lying, 19.1% standing and 11.3% stepping. Weekdays and weekends differed significantly in total time spent sitting/lying, standing, stepping, step count, number of sedentary bouts and length of sedentary bouts (p < 0.05, respectively). Obese children spent a large proportion of their time sedentarily, and they spent more time sedentarily during weekends compared with weekdays. This study on sedentary behaviour patterns presents valuable information for designing and implementing strategies to decrease sedentary time among obese children, particularly during weekends.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation*
  8. Singh OP, Ahmed IB, Malarvili MB
    Technol Health Care, 2018;26(5):785-794.
    PMID: 30124456 DOI: 10.3233/THC-181288
    BACKGROUND: Assessment of asthma outside of the hospital using a patient independent device is highly in demand due to the limitation of existing devices, which are manual and unreliable if patients are not cooperative.

    OBJECTIVE: The study aims to verify the use of newly developed human respiration, carbon dioxide (CO2) measurement device for the management of asthma outside of the hospital.

    METHOD: The data were collected from 60 subjects aged between 18-35 years via convenience sampling method reported in UTM Health Center using the device. Furthermore, the data were normalized and analyzed using descriptive statistics, t-test, and area (Az) under receiver operating characteristic curve (ROC).

    RESULT: Findings revealed that the normalized mean values of end-tidal carbon dioxide (EtCO2), Hjorth Activity (HA), and respiratory rate (RR) were lower in asthmatic compared with healthy subjects with minimum deviation from the mean. In addition, each parameter was found to significantly differ statistically for asthma and non-asthma with p< 0.05. Furthermore, the Az shows the strong association for the screening of asthma and non-asthma with an average of 0.71 (95% CI: 0.57-0.83), 0.77 (95% CI: 0.64-0.90), and 0.83 (95% CI: 0.73-0.94) for RR, EtCO2, and HA, respectively.

    CONCLUSIONS: This study demonstrates that the newly developed handheld human respiration CO2 measurement device may possibly be used as an effort-independent asthma management method outside of the hospital.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation*
  9. Al-Fakih EA, Osman NA, Eshraghi A, Adikan FR
    Sensors (Basel), 2013 Aug 12;13(8):10348-57.
    PMID: 23941909 DOI: 10.3390/s130810348
    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
    Matched MeSH terms: Monitoring, Ambulatory/instrumentation*
  10. Kario K, Tomitani N, Buranakitjaroen P, Chia YC, Park S, Chen CH, et al.
    J Clin Hypertens (Greenwich), 2018 12;20(12):1686-1695.
    PMID: 30444315 DOI: 10.1111/jch.13415
    A self-measured home blood pressure (BP)-guided strategy is an effective practical approach to hypertension management. The Asia BP@Home study is the first designed to investigate current home BP control status in different Asian countries/regions using standardized home BP measurements taken with the same validated home BP monitoring device with data memory. We enrolled 1443 medicated hypertensive patients from 15 Asian specialist centers in 11 countries/regions between April 2017 and March 2018. BP was relatively well controlled in 68.2% of patients using a morning home systolic BP (SBP) cutoff of <135 mm Hg, and in 55.1% of patients using a clinic SBP cutoff of <140 mm Hg. When cutoff values were changed to the 2017 AHA/ACC threshold (SBP <130 mm Hg), 53.6% of patients were well controlled for morning home SBP. Using clinic 140 mm Hg and morning home 135 mm Hg SBP thresholds, the proportion of patients with well-controlled hypertension (46%) was higher than for uncontrolled sustained (22%), white-coat (23%), and masked uncontrolled (9%) hypertension, with significant country/regional differences. Home BP variability in Asian countries was high, and varied by country/region. In conclusion, the Asia BP@Home study demonstrated that home BP is relatively well controlled at hypertension specialist centers in Asia. However, almost half of patients remain uncontrolled for morning BP according to new guidelines, with significant country/regional differences. Strict home BP control should be beneficial in Asian populations. The findings of this study are important to facilitate development of health policies focused on reducing cardiovascular complications in Asia.
    Matched MeSH terms: Blood Pressure Monitoring, Ambulatory/instrumentation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links