Displaying publications 21 - 40 of 44 in total

Abstract:
Sort:
  1. Pirouzi G, Abu Osman NA, Oshkour AA, Ali S, Gholizadeh H, Abas WA
    Sensors (Basel), 2014;14(9):16754-65.
    PMID: 25207872 DOI: 10.3390/s140916754
    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.
  2. Arifin N, Abu Osman NA, Ali S, Gholizadeh H, Abas WA
    ScientificWorldJournal, 2014;2014:856279.
    PMID: 25003155 DOI: 10.1155/2014/856279
    This study aimed to evaluate the effects of prosthetic foot types on the postural stability among transtibial amputees when standing on different support surfaces.
  3. Gholizadeh H, Osman NA, Eshraghi A, Abd Razak NA
    Biomed Eng Online, 2014;13:89.
    PMID: 24981801 DOI: 10.1186/1475-925X-13-89
    Prosthesis suspension systems can alter the distribution of pressure within the prosthetic socket. This study evaluates a new suspension system for lower limb prostheses, and aims to compare the interface pressure and amputees' satisfaction with the new system compared with a common prosthetic suspension system (pin/lock).
  4. Pirouzi G, Abu Osman NA, Eshraghi A, Ali S, Gholizadeh H, Wan Abas WA
    ScientificWorldJournal, 2014;2014:849073.
    PMID: 25197716 DOI: 10.1155/2014/849073
    Socket is an important part of every prosthetic limb as an interface between the residual limb and prosthetic components. Biomechanics of socket-residual limb interface, especially the pressure and force distribution, have effect on patient satisfaction and function. This paper aimed to review and evaluate studies conducted in the last decades on the design of socket, in-socket interface pressure measurement, and socket biomechanics. Literature was searched to find related keywords with transtibial amputation, socket-residual limb interface, socket measurement, socket design, modeling, computational modeling, and suspension system. In accordance with the selection criteria, 19 articles were selected for further analysis. It was revealed that pressure and stress have been studied in the last decaeds, but quantitative evaluations remain inapplicable in clinical settings. This study also illustrates prevailing systems, which may facilitate improvements in socket design for improved quality of life for individuals ambulating with transtibial prosthesis. It is hoped that the review will better facilitate the understanding and determine the clinical relevance of quantitative evaluations.
  5. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    PLoS One, 2014;9(5):e94520.
    PMID: 24827560 DOI: 10.1371/journal.pone.0094520
    The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction) and the Dermo (pin/lock) suspension systems on amputees' gait performance.
  6. Eshraghi A, Abu Osman NA, Karimi M, Gholizadeh H, Soodmand E, Wan Abas WA
    PLoS One, 2014;9(5):e96988.
    PMID: 24865351 DOI: 10.1371/journal.pone.0096988
    Prosthetic suspension system is an important component of lower limb prostheses. Suspension efficiency can be best evaluated during one of the vital activities of daily living, i.e. walking. A new magnetic prosthetic suspension system has been developed, but its effects on gait biomechanics have not been studied. This study aimed to explore the effect of suspension type on kinetic and kinematic gait parameters during level walking with the new suspension system as well as two other commonly used systems (the Seal-In and pin/lock). Thirteen persons with transtibial amputation participated in this study. A Vicon motion system (six cameras, two force platforms) was utilized to obtain gait kinetic and kinematic variables, as well as pistoning within the prosthetic socket. The gait deviation index was also calculated based on the kinematic data. The findings indicated significant difference in the pistoning values among the three suspension systems. The Seal-In system resulted in the least pistoning compared with the other two systems. Several kinetic and kinematic variables were also affected by the suspension type. The ground reaction force data showed that lower load was applied to the limb joints with the magnetic suspension system compared with the pin/lock suspension. The gait deviation index showed significant deviation from the normal with all the systems, but the systems did not differ significantly. Main significant effects of the suspension type were seen in the GRF (vertical and fore-aft), knee and ankle angles. The new magnetic suspension system showed comparable effects in the remaining kinetic and kinematic gait parameters to the other studied systems. This study may have implications on the selection of suspension systems for transtibial prostheses. Trial registration: Iranian Registry of Clinical Trials IRCT2013061813706N1.
  7. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Arifin N, Wan Abas WA
    Biomed Eng Online, 2014;13:1.
    PMID: 24410918 DOI: 10.1186/1475-925X-13-1
    Good prosthetic suspension system secures the residual limb inside the prosthetic socket and enables easy donning and doffing. This study aimed to introduce, evaluate and compare a newly designed prosthetic suspension system (HOLO) with the current suspension systems (suction, pin/lock and magnetic systems).
  8. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014;13:134.
    PMID: 25208636 DOI: 10.1186/1475-925X-13-134
    Understanding of kinematics force applied at the elbow is important in many fields, including biomechanics, biomedical engineering and rehabilitation. This paper provides a comparison of a mathematical model of elbow joint using three different types of prosthetics for transhumeral user, and characterizes the forces required to overcome the passive mechanical of the prosthetics at the residual limb.
  9. Eshraghi A, Abu Osman NA, Gholizadeh H, Ali S, Abas WA
    Am J Phys Med Rehabil, 2015 Jan;94(1):1-10.
    PMID: 24919079 DOI: 10.1097/PHM.0000000000000134
    This study aimed to compare the effects of different suspension methods on the interface stress inside the prosthetic sockets of transtibial amputees when negotiating ramps and stairs.
  10. Sheykhi-Dolagh R, Saeedi H, Farahmand B, Kamyab M, Kamali M, Gholizadeh H, et al.
    Prosthet Orthot Int, 2015 Jun;39(3):190-6.
    PMID: 24604086 DOI: 10.1177/0309364614521652
    BACKGROUND: Flexible flat foot is described as a reduction in the height of the medial longitudinal arch and may occur from abnormal foot pronation. A foot orthosis is thought to modify and control excessive pronation and improve arch height.
    OBJECTIVE: To compare the immediate effect of three types of orthoses on foot mobility and the arch height index in subjects with flexible flat feet.
    STUDY DESIGN: A quasi-experimental study.
    METHOD: The dorsal arch height, midfoot width, foot mobility and arch height index were assessed in 20 participants with flexible flat feet (mean age = 23.2 ± 3 years) for three different foot orthosis conditions: soft, semi-rigid and rigid University of California Biomechanics Laboratory (UCBL).
    RESULTS: Maximum midfoot width at 90% with arch mobility in the coronal plane was shown in the semi-rigid orthosis condition. The semi-rigid orthosis resulted in the highest mean foot mobility in 90% of weight bearing, and the rigid orthosis (UCBL) had the lowest mean foot mobility. The soft orthosis resulted in foot mobility between that of the rigid and the semi-rigid orthosis. UCBL orthosis showed the highest arch height index, and the semi-rigid orthosis showed the lowest mean arch height index.
    CONCLUSION: Due to its rigid structure and long medial-lateral walls, the UCBL orthosis appears to limit foot mobility. Therefore, it is necessary to make an orthosis that facilitates foot mobility in the normal range of the foot arch. Future studies should address the dynamic mobility of the foot with using various types of foot orthoses.
    CLINICAL RELEVANCE: Although there are many studies focussed on flat foot and the use of foot orthoses, the mechanism of action is still unclear. This study explored foot mobility and the influence of foot orthoses and showed that a more rigid foot orthosis should be selected based on foot mobility.
    KEYWORDS: Foot orthosis; arch height index; foot mobility magnitude
  11. Arifin N, Abu Osman NA, Ali S, Gholizadeh H, Wan Abas WA
    Proc Inst Mech Eng H, 2015 Jul;229(7):491-8.
    PMID: 26019139 DOI: 10.1177/0954411915587595
    In recent years, computerized posturography has become an essential tool in quantitative assessment of postural steadiness in the clinical settings. The purpose of this study was to explore the ability of the Biodex(®) Stability System (BSS) to quantify postural steadiness in below-knee amputees. A convenience sample of 10 below-knee amputees participated in the study. The overall (OSI), anterior-posterior (APSI) and medial-lateral (MLSI) stability indexes as well as the percentage of time spent in left and right quadrants and four concentric zones were measured under altered sensory conditions while standing with solid ankle cushion heel (SACH), single-axis (SA) and energy storage and release (ESAR) feet. Significant difference was found between sensory conditions in SACH and ESAR feet for OSI (SACH, p = 0.002; ESAR, p = 0.005), APSI (SACH, p = 0.036; ESAR, p = 0.003) and MLSI (SACH, p = 0.008; ESAR, p = 0.05) stability indexes. The percentage of time spent in Zone A (0°-5°) was significantly greater than the other three concentric zones (p < 0.01). The loading time percentage on their intact limb (80%-94%) was significantly longer than the amputated limb (20%-6%) in all conditions for all three prosthetic feet. Below-knee amputees showed compromised postural steadiness when visual, proprioceptive or vestibular sensory input was altered. The findings highlight that the characteristics of postural stability in amputees can be clinically assessed by utilizing the outcomes produced by the BSS.
  12. Gholizadeh H, Abu Osman NA, Eshraghi A, Arifin N, Chung TY
    Prosthet Orthot Int, 2016 Aug;40(4):509-16.
    PMID: 25583929 DOI: 10.1177/0309364614564022
    BACKGROUND: This article describes a total surface bearing prosthetic socket for a patient (25-year-old female) with a bulbous stump.

    CASE DESCRIPTION AND METHODS: The subject had unstable excessive soft tissue at the distal end of the residuum. After 2 years of prosthetic use, she experienced several problems, including pain in the residual limb and knee joint. Pressure distribution was evaluated during ambulation. We also designed a total surface bearing socket with Velcro as suspension system to distribute the load evenly on the residual limb, and to facilitate donning procedure.

    FINDINGS AND OUTCOMES: The main site of weight bearing in the old prosthesis (patellar tendon bearing) was anterior proximal region of the residual limb, especially the patellar tendon. The pressure was almost 10 times higher than the distal region during level walking. Pressures were distributed more evenly with the total surface bearing socket design, and the donning was much easier.

    CONCLUSION: Pressure distribution within the socket could be affected by socket design and suspension system. Using the total surface bearing socket and Velcro as suspension system might facilitate donning of prosthesis and reduce traction at the end of residual limb during the swing phase of gait.

    CLINICAL RELEVANCE: Proper socket design and suspension system based on the amputees' need can facilitate rehabilitation process and lead to the amputee's satisfaction. The pressure is distributed more uniformly over the residual limb by the total surface bearing socket compared to the patellar tendon bearing socket for lower limb amputees with unusual stump shape.

  13. Gholizadeh H, Lemaire ED, Eshraghi A
    Clin Biomech (Bristol, Avon), 2016 08;37:108-116.
    PMID: 27423025 DOI: 10.1016/j.clinbiomech.2016.06.005
    BACKGROUND: An optimal suspension system can improve comfort and quality of life in people with limb loss. To guide practice on prosthetic vacuum suspension systems, assessment of the current evidence and professional opinion are required.

    METHODS: PubMed, Web of Science, and Google Scholar databases were explored to find related articles. Search terms were amputees, artificial limb, prosthetic suspension, prosthetic liner, vacuum, and prosthesis. The results were refined by vacuum socket or vacuum assisted suspension or sub-atmospheric suspension. Study design, research instrument, sample size, and outcome measures were reviewed. An online questionnaire was also designed and distributed worldwide among professionals and prosthetists (www.ispoint.org, OANDP-L, LinkedIn, personal email).

    FINDINGS: 26 articles were published from 2001 to March 2016. The number of participants averaged 7 (SD=4) for transtibial and 6 (SD=6) for transfemoral amputees. Most studies evaluated the short-term effects of vacuum systems by measuring stump volume changes, gait parameters, pistoning, interface pressures, satisfaction, balance, and wound healing. 155 professionals replied to the questionnaire and supported results from the literature. Elevated vacuum systems may have some advantages over the other suspension systems, but may not be appropriate for all people with limb loss.

    INTERPRETATION: Elevated vacuum suspension could improve comfort and quality of life for people with limb loss. However, future investigations with larger sample sizes are needed to provide strong statistical conclusions and to evaluate long-term effects of these systems.

  14. Abu Osman NA, Gholizadeh H, Eshraghi A, Wan Abas WAB
    Prosthet Orthot Int, 2017 Oct;41(5):476-483.
    PMID: 28946824 DOI: 10.1177/0309364616670396
    OBJECTIVES: This study aimed to evaluate and compare a newly designed suspension system with a common suspension in the market.

    STUDY DESIGN: Prospective study.

    METHODS: Looped liners with hook fastener and Iceross Dermo Liner with pin/lock system were mechanically tested using a tensile testing machine in terms of system safety. A total of 10 transtibial amputees participated in this study and were asked to use these two different suspension systems. The pistoning was measured between the liner and socket through a photographic method. Three static axial loading conditions were implemented, namely, 30, 60, and 90 N. Furthermore, subjective feedback was obtained.

    RESULTS: Tensile test results showed that both systems could safely tolerate the load applied to the prosthesis during ambulation. Clinical evaluation confirmed extremely low pistoning in both systems (i.e. less than 0.4 cm after adding 90 N traction load to the prosthesis). Subjective feedback also showed satisfaction with both systems. However, less traction at the end of the residual limb was reported while looped liner was used.

    CONCLUSION: The looped liner with hook fastener is safe and a good alternative for individuals with transtibial amputation as this system could solve some problems with the current systems. Clinical relevance The looped liner and hook fastener were shown to be good alternative suspension for people with lower limb amputation especially those who have difficulty to use and align the pin/lock systems. This system could safely tolerate centrifugal forces applied to the prosthesis during normal and fast walking.

  15. Abu Osman NA, Eshraghi A, Gholizadeh H, Wan Abas WAB, Lechler K
    Prosthet Orthot Int, 2017 Dec;41(6):571-578.
    PMID: 28190376 DOI: 10.1177/0309364617690397
    OBJECTIVES: To develop a questionnaire that specifically evaluates the ability of trans-tibial amputees to don and doff a prosthesis and to investigate the psychometric properties of the newly developed questionnaire.

    BACKGROUND: Prosthesis should be donned and doffed few times during the day and night; thus, it is important to measure ease of donning and doffing.

    STUDY DESIGN: A cross-sectional study.

    METHODS: The questionnaire was designed and evaluated by a group of experts. The final questionnaire was administered to 50 individuals with trans-tibial amputation. A test-retest study was also conducted on 20 amputees to assess the repeatability of questionnaire items.

    RESULTS: The prosthesis donning and doffing questionnaire was developed and tested through a pilot study. Based on Kappa index, the questionnaire items showed correlation coefficients greater than 0.7, which indicate good reliability and repeatability. The majority of the participants had good hand dexterity (80%) and could perform all types of grasps. The mean satisfaction scores with donning and doffing were 69.9 and 81.4, respectively. Most of the respondents needed to don and doff the prosthesis 3.44 times per day. Based on a 7-point score, the total scores ranged between 3 and 7.

    CONCLUSION: The prosthesis donning and doffing questionnaire items showed good psychometric properties. A scoring method was suggested based on the pilot sample, which requires further evaluation to be able to differentiate between more suspension types. A larger international multicenter evaluation is required in the future to measure the responsiveness of the scales. This questionnaire will be useful in the evaluation of the ability of amputees to don and doff a trans-tibial limb prosthesis. Clinical relevance Donning and doffing of prostheses are challenging tasks for many lower limb amputees. The prosthesis donning and doffing questionnaire, on its own or combined with other prosthetic evaluation questionnaires, has the potential to help manufacturers, clinicians, and researchers gain knowledge and improve the donning and doffing qualities of prostheses.

  16. Hashim NA, Abd Razak NA, Abu Osman NA, Gholizadeh H
    Proc Inst Mech Eng H, 2018 Jan;232(1):3-11.
    PMID: 29199518 DOI: 10.1177/0954411917744585
    Body-powered prostheses are known for their advantages of cost, reliability, training period, maintenance, and proprioceptive feedback. This study primarily aims to analyze the work related to the improvement of upper limb body-powered prostheses prior to 2016. A systematic review conducted via the search of the Web of Science electronic database, Google Scholar, and Google Patents identified 155 papers from 1921 to 2016. Sackett's initial rules of evidence were used to determine the levels of evidence, and only papers categorized in the design and development category and patents were analyzed. A total of 40 papers in the sixth level of "Design and Development" of an upper limb body-powered prosthesis were found. Approximately 81% were categorized under mechanical alteration. Most papers were patent-type documents (48%), with the Journal of Rehabilitation Research and Development publishing most of the articles related to the design and development of body-powered prostheses. Papers in the scope of the study were published once every 3 years in almost a century, proving that only a few studies were conducted to improve body-powered arms compared with myoelectric technology. Further research should be carried out mainly in areas that have received less attention.
  17. Ghazali MF, Abd Razak NA, Abu Osman NA, Gholizadeh H
    Turk J Phys Med Rehabil, 2018 Sep;64(3):268-276.
    PMID: 31453521 DOI: 10.5606/tftrd.2018.1668
    Objectives: This study aims to assess the level of awareness of transtibial amputee patients on stump contractures and their compliance with efforts implemented to prevent the condition.

    Patients and methods: This study included 50 unilateral transtibial amputees (26 males, 24 females; mean age 55.4±14.7 years; range, 18 to 78 years) who met the respondent criteria of the study. The respondents were randomly selected and were issued with a questionnaire.

    Results: The majority of the transtibial amputees were aware of stump contracture complications. It was found that they also preferred methods of prevention which required less effort, was cost-effective, and were also practical.

    Conclusion: More focus should be placed on contracture prevention methods which were most complied with by the patients. This is because the effectiveness of a prevention method is highly influenced by patients' compliance with the method. Patients with a higher risk of developing stump contractures should be also given more attention in post-amputation care.

  18. Mehmood W, Abd Razak NA, Lau MS, Chung TY, Gholizadeh H, Abu Osman NA
    Proc Inst Mech Eng H, 2019 Feb;233(2):181-192.
    PMID: 30518308 DOI: 10.1177/0954411918816124
    Transtibial prosthetic sockets can be fabricated either by the conventional way, which involve using plaster of Paris bandages for casting. This will include modifications through hand, scanning and digital imaging of software. The aim of this study is to determine the circumferential profiles and conduct a volumetric analysis of a conventional socket that has fabrication using biosculptor technology. In doing this, a male transtibial amputee, age 28 years old with stable health condition was studied, where circumferential measurements were taken at intervals of 1 cm from the distal end of the residual limb to the medial tibial plateau level. Furthermore, the interior volume of both sockets and residuum were determined directly using water displacement method. A comparative value for the calculation of volume was also carried out using engineering mathematical equations. From these measurements, a total surface bearing transtibial sockets was fabricated to compare the changes of circumferential values of both sockets. The finding shows a percentage of the difference between the volume of the residual limb and conventional sockets to be 6.09%, whereas the biosculptor fabrication socket was 7.84% using the water displacement method. A comparison of circumferential profiles and volumetric analysis findings on the contrary showed that socket fabricated using the biosculptor technology is interchangeable with the conventional socket with more advantages, where biosculptor technology produces cheaper sockets and faster process with digital function in the procedure, unlike the conventional manual technique.