In this paper, we report the effects of a side-polished fiber (SPF) coated with titanium (Ti) films in different thicknesses, namely 5 nm, 13 nm, and 36 nm, protected by a thin layer of transition metal dichalcogenides (TMDCs) such as molybdenum disulfide (MoS2) and tungsten disulfide (WS2), which provide ultra-sensitive sensor-based surface plasmon resonance (SPR) covering from the visible to mid-infrared region. The SPF deposited with Ti exhibits strong evanescent field interaction with the MoS2 and WS2, and good optical absorption, hence resulting in high-sensitivity performance. Incremental increases in the thickness of the Ti layer contribute to the enhancement of the intensity of transmission with redshift and broad spectra. The findings show that the optimum thickness of Ti with 36 nm combined with MoS2 causes weak redshifts of the longitudinal localized surface plasmon resonance (LSPR) mode, while the same thickness of Ti with WS2 causes large blueshifts. The redshifts are possibly due to a reduced plasmon-coupling effect with the excitonic region of MoS2. The observed blueshifts of the LSPR peak position are possibly due to surface modification between WS2 and Ti. Changing the relative humidity from 58% to 88% only elicited a response in Ti/MoS2. Thus, MoS2 shows more sensitivity on 36-nm thickness of Ti compared with WS2. Therefore, the proposed fiber-optic sensor with integration of 2D materials is capable of measuring humidity in any environment.
Passively harmonic mode-locking has been experimentally demonstrated in an erbium-doped fiber laser with large normal dispersion using single-multi-single mode structure as artificial saturable absorber. By increasing the pump power under the same polarization setting, the mode-locking operation can switch from fundamental mode-locked to 5th order harmonic mode-locked. Highest repetition rate of 4.26 MHz (5th order harmonic) is observed, with pulse width and pulse energy ascertained at 290 fs and 3.0 nJ, respectively. Excellent signal-to-noise ratio (SNR) of above 50 dB is observed for all harmonic orders. The findings validated that SMS structure can be used to generate stable and switchable high order of harmonic mode-locked. The low-cost SMS fiber for harmonic mode-locked generation technique could lay the groundwork for future sustainable industrial growth.
Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.
A stable dual-wavelength thulium-doped fiber laser operating at 1.9 μm using a short length of photonic crystal fiber (PCF) has been proposed and demonstrated. The photonics crystal fiber was 10 cm in length and effectively acted as a Mach-Zehnder interferometry element with a free spectral range of 0.2 nm. This dual-wavelength thulium-doped fiber laser operated steadily at room temperature with a 45 dB optical signal-to-noise-ratio.
We experimentally demonstrated the generation of domain-wall dark pulse in an Erbium-doped fiber laser using the combination of a 10 cm graded index multimode fiber sandwiched by single mode fibers as artificial saturable absorber. The interaction of phase difference in grade index multimode fiber allowed the stable dual-wavelength oscillation in the cavity. The dual-wavelength centered at 1567.2 nm and 1569.4 nm produces the topological defect in temporal domain and achieved a dark pulse formation with repetition rate of 21.5 MHz. The highest average pulse energy is calculated as 769.6 pJ with pulse width of 5 ns. Throughout the operating pump power range, the average pulse energy and output power increase linearly, with R2 of 0.9999 and achieved the laser efficiency of 9.33%. From the measurement in frequency domain, the signal-to-noise ratio is measured as 49 dB. As compared to reported DW dark pulse works, the proposed structure only required a short length of multimode fiber, which allowed the domain-wall dark pulse to achieve higher pulse repetition rate. The venture of domain wall dark pulse is potentially to pave the foundation toward sustainable industrial growth.
We demonstrate mode locking of a thulium-bismuth codoped fiber laser (TBFL) operating at 1901.6 nm, using a graphene-based saturable absorber (SA). In this work, a single layer graphene is mechanically exfoliated using the scotch tape method and directly transferred onto the surface of a fiber pigtail to fabricate the SA. The obtained Raman spectrum characteristic indicates that the graphene on the core surface has a single layer. At 1552 nm pump power of 869 mW, the mode-locked TBFL self starts to generate an optical pulse train with a repetition rate of 16.7 MHz and pulse width of 0.37 ps. This is a simple, low-cost, stable, and convenient laser oscillator for applications where eye-safe and low-photon-energy light sources are required, such as sensing and biomedical diagnostics.
An efficient and low cost optical method for directly measuring the concentration of homogenous biological solutes is proposed and demonstrated. The proposed system operates by Fresnel reflection, with a flat-cleaved single-mode fiber serving as the sensor probe. A laser provides a 12.9 dBm sensor signal at 1,550 nm, while a computer-controlled optical power meter measures the power of the signal returned by the probe. Three different mesenchymal stem cell (MSC) lines were obtained, sub-cultured and trypsinized daily over 9 days. Counts were measured using a haemocytometer and the conditioned media (CM) was collected daily and stored at -80 °C. MSCs release excretory biomolecules proportional to their growth rate into the CM, which changes the refractive index of the latter. The sensor is capable of detecting changes in the number of stem cells via correlation to the change in the refractive index of the CM, with the measured power loss decreasing approximately 0.4 dB in the CM sample per average 1,000 cells in the MSC subculture. The proposed system is highly cost-effective, simple to deploy, operate, and maintain, is non-destructive, and allows reliable real-time measurement of various stem cell proliferation parameters.
Dengue diagnostics have come a long way. Attempts at breaking away from lab-oriented dengue detection, such as NS1 antigen, IgM or IgG antibodies detection have extensively received numerous coverage. As a result, rapid detection tests (RDTs) have started to gain inroads in medical practice. Rapid detection tests notwithstanding, analysis of blood serum is still a relatively complicated task. This includes the necessity of phlebotomy, centrifugation for blood serum, and other reagent-based tests. Therefore, a non-invasive method of dengue detection was considered. In this study, we present the utility of diffuse reflectance skin spectroscopy (bandwidth of 200-2500nm) on the forearm during the triaging period for dengue screening potential. This is performed with multivariate analysis of 240 triaged febrile/suspected dengue patients. The data is then scrutinized for its clinical validity to be included as either confirmed or probable dengue, or a control group. Based on discriminant analysis of several data normalization models, we can predict the patients' clinical dengue-positivity at ranges of accuracy between ~93-98% depending on mode of the data, with a probably optimal sensitivity and specificity to the clinical diagnosis of ~89% and ~100% respectively. From the outcomes of this study, we recommend further trials with cautious optimism. With these findings, it is hoped that the elusive non-invasive detection of tropical diseases may gain platform in the near future.